background image

- 1 -

PJ2-3005-4CA-PE

PARALLEL

L1

L2

HLV3

 

Series

Spot Lights

Instruction Guide

Thank you for purchasing a CCS product. To ensure proper use of the product, 
please read this instruction guide before use and keep it for your future reference.

  The following symbols in the instruction guide indicate and classify the precautions.

  The following symbols are used in this instruction guide to indicate and classify 

the relative importance of warnings and cautions.

Warning

Do not disassemble or modify the Spot Light.  

Doing so may result in fire or electric shock.

DISASSEMBLY

PROHIBITED

LED light radiation may cause corneal or 

retinal abnormalities if you look directly at 

the light. To prevent harmful light exposure, 

never look directly at the LED light.

MANDATORY

ACTIONS

Do not touch the Spot Light with wet hands.  

Doing so may result in electric shock.

DO NOT TOUCH

WITH WET HANDS

This product generates high temperatures.  Do 

not touch the Spot Light while it is turned on 

or immediately after it is turned off, or burning 

may result. Provide cooling with a fan or other 

ventilation if the Spot Light is to be used in a 

closed space.

MANDATORY

ACTIONS

Make sure that the Spot Light is free of 

moisture or any liquid. Exposure to water may 

result in fire or electric shock.

DO NOT SUBJECT 

TO MOISTURE

Connect or disconnect the light cable only after 

turning off the Control Unit for LED Light Units.  

Failure to do so may result in circuit damage, 

fire caused by a minute spark, or electric shock.

MANDATORY

ACTIONS

If abnormal condition occurs such as fuming, 

heat, smell, noise, or so on, stop using 

the Spot Light immediately, turn OFF the 

Dedicated Control Unit and unplug the power 

cord.  A fire or electric shock may result if the 

Spot Light is kept used.

MANDATORY

ACTIONS

Using Infrared Light Units (HLV3-22IR860)

Make known to all personnel concerned the 

risk of ultraviolet radiation. Failure to do so 

may cause incorrect handling.

MANDATORY

ACTIONS

These products have been designed with full consideration of safety. However, incorrect 

usage of the products may result in fire, electric shock, or other serious damages. Please 

ensure to follow the conditions below.

These symbols indicate prohibited actions.

This symbol indicates required actions.

DO NOT TOUCH

WITH WET HANDS

PROHIBITED

MANDATORY

ACTIONS

DO NOT SUBJECT 

TO MOISTURE

  Please install the Spot Light to locations with following conditions.

Incorrect installation location may cause Spot Light failure.

In a flat and stable location with minimal vibration.

Well-ventilated places with minimal dust.
Places that are not subject to sudden temperature 
changes.

Places free from any water, oil, liquid, chemical, or steam.
Places free from corrosive or combustible gas.

Places away from water faucets, boilers, humidifiers, 

air conditioners, heaters, or stoves.

  Do not use the Spot Light in the following situations. 

Under conditions or in an environment not described in this Instruction Guide.
In nuclear energy control systems, railroad systems, aviation systems, vehicles, combustion equipment, 
medical equipment, amusement machines, or safety equipment. 
In applications involving serious risk to life or property, particularly applications demanding a high level of safety.

DISASSEMBLY

PROHIBITED

Caution

Do not use user-made cables. Doing so may 

cause Spot Light failure. Use the CCS extension 

cable if it is necessary to extend the distance 

between the light and the Control Unit.

PROHIBITED

Use a standard Extension Cable that is 

manufactured by CCS. However, if the cable 

is too long, the light intensity will decrease 

due to voltage drop caused by the DC 

resistance of the cable.

MANDATORY

ACTIONS

Do not use the branch cables. Doing so may 

cause Spot Light failure.

PROHIBITED

A lways c onnec t the Spot Lights to the 

Dedicated Control Units specified by CCS. 

Not doing so may cause Spot Light failure.

MANDATORY

ACTIONS

Be careful of static electricity. Damage to the 

Spot Light may occur, if a person charged 

with static electricity touches it. Keep the Spot 

Light away from all items charged with static 

electricity.

PROHIBITED

Do not drop the Spot Light or subject it to 

impact. Doing so may cause the Spot Light to 

malfunction.

PROHIBITED

Warning

Indicates that incorrect 

usage may result in serious 

injury or death.

Caution

Indicates that incorrect 

usage may result in injury 

or property damage.

Confirming Product Information

LED Light for Machine Vision 

and Indust r ial Insp ec t ion

Important Information for Equipment Safety  

- Read Before Use -

1

2

3

The following tag is attached to the cable on the LED Light. The color of the label indicates 
the luminescence color of the Light. The back of the tag there is a name label that gives the 
model number, power consumption, and serial number. Be sure to check the contents before 
using the product and handle the label with care. If the label is missing or damaged and the 
contents cannot be checked, please contact CCS Inc.

Major Combinations

HLV3-22-4-NR Series

5

HLV3-3M-RGB-4

6

HLV3-22-1/2 Series

2

HLV3-22-2-1220 Series

3

HLV3-22-4M/4S Series

HLV3-22IR860

4

The HLV3-series Spot Lights are used in combination with a coaxial lens or other equipment. 
Refer to the following figures, mount the Spot Light on a coaxial lens, and fix it with an 
appropriate torque.
The numbers (

1

 to 

12

) in the figures below correspond to those in 

7. Main Specifications

 and 

8. Dimensions.

  Mounting on a Coaxial Lens

The Spot Light can be mounted 
on a coaxial lens.
The inner diameter of the lens for 
mounting the Spot Light 

1

2

, or 

4

 must be 8 mm, and that for the 

Spot Light 

3

 must be 12 mm.

  Mounting on a Microfiber Head

5

6

Microfiber Heads 

series

Connecting adaptor (included with the Microfiber Head)

Light Sources 

5

 and 

6

 are 

d e d i c a t e d l y   d e s i g n e d   f o r 
Microfiber Head. For detailed 
i n f o r m a t i o n ,   r e f e r   t o   t h e 
instruction guide for Microfiber 
Heads.

4

Control Unit

connector

Spot Light
connector

Operating Instructions

1)  Connect the light cable of the Spot Light 

to the Dedicated Control Unit output 
connector.

2) Turn ON the Dedicated Control Unit, and 

then turn ON the Spot Light.

3) Focus the imaging device, such as a 

camera, onto the inspection object.

4) Adjust light range, light angle, and radiant 

quantity to optimize images. Adjust the 
radiant quantity at the Dedicated Control 
Unit. 

Read the instr uction guide for the 
Dedicated Control Unit before use.

HLV3-14 Series

1

  Mounting on a Condenser Lens 

(Optional Product, Sold Separately)

The Spot Light can be mounted 
on a Condenser Lens (

7

 to 

11

).

Use a Light Aperture Adapter 
(

12

) as needed.

For detailed dimensions of the Condenser Lenses and Light Aperture Adapters, refer to 

8. Dimensions

Make sure that the Dedicated Control Unit is turned OFF before you connect the Spot Light.

MANDATORY

ACTIONS

Using Infrared Spot Light (HLV3-22IR860)

Do not expose human eyes to IR radiation. Also, make known to all personnel 

concerned the risk of IR radiation.

Caution

MANDATORY

ACTIONS

Using RGB Spot Lights (HLV3-3M-RBG-4)

Changes in radiant quantities over time are different for different colors (red, green, and 

blue). If you use different colors at the same time, you will need to adjust them periodically.

Coaxial lens
(macro lens 
or telecentric 
lens)

Camera

2

3

1

4

2 4

7

11

to

HLV3-series
Spot Light

Coaxial lens

Camera

Inspection object

Dedicated 
Control Unit

M A D E   I N   J A P A N

M O D E L
I N P U T
S / N

H L V 3 - n n R D - 2

n n n m A = n . n W

0 1 2 3 4 5 6 7 8 9

M a n u f a c t u r e r :           C C S   I n c .
3 7 4   O k a k u e n c h o ,   K a m i g y o - k u ,
K y o t o   6 0 2 - 8 0 1 1 ,   J a p a n
E U   I m p o r t e r :             C C S   E u r o p e   N .   V .
B e r g e n s e s t e e n w e g   4 2 1 B ,
1 6 0 0   S i n t - P i e t e r s - L e e u w ,   B e l g i u m

Tag example

Back

Front

12

HL-30,
HL-24-21,
HL2-25-P,
HL2-50-P, or
HL2-M50-C

SB-HL2
series

Reviews: