background image

Technical instructions

WPX30

v2.0EN

B. Declaration of conformity

Bleu Electrique SAS (FR47403521693) declares that the pro-

ductWPX30 meets the safety and electromagnetic compatibility re-

quirements of European Directives 2006/95/EC and 2004/108/EC.

Emmanuel Baret

Marseilles, on 28/10/2016

Distributor's stamp

Date of sale: . . . . . . . . . . . . . . . . . . . . . . . Batch N°: . . . . . . . . . . . . . . . . . . . . . . . . . . .

www.c-

cei.fr

12

Summary of Contents for BRIO WPX30

Page 1: ...4 Compatibility Control 4 5 Use Autonomous mode 5 6 Safety 5 7 Installation 6 8 Electrical Connections 8 9 Transformer power 9 10 Projector Protection 9 11 Cable section 10 A Connection schematic 11 B...

Page 2: ...o colour Weight 1 2kg projector cable 1 4kg packaged LED type 9 powerful monochrome LEDs 3R 3G 3B 6 MidPower cool white LEDs 6000 K Risk group 1 low risk according to IEC62471 2006 Protection index IP...

Page 3: ...l LED to improve the quality and reli ability of the lighting of your pool while reducing your energy consumption The colours are created by mixing 3 primary colours Red R Green G for Green and Blue B...

Page 4: ...with RC compatible products In RC mode only install the lights RC compatible products Compatibility with the other products of the range Mode RC Brio RC MOD Brio RC Me teoR OPT Brio RC Mode RC Brio R...

Page 5: ...ndom sequence 1 18 Sequence Random sequence 2 Change of mode The mode can be changed by cutting the power supply of the lights for a very short space of time less than 1s By successive interruptions i...

Page 6: ...th its nut E in concrete and glue an O ring F before positioning the liner Place then an O ring F at the pool side and screw the cable gland A The wall support is fixed directly on the wall using the...

Page 7: ...the wall conduit B and fix it with the nut E Glue an O ring F on the panel before positioning the liner Glue a second O ring F at the pool side after placing the liner Screw then the body of the cable...

Page 8: ...r cuit breaker If you are not sure if these types of devices are fitted contact a qualified electrician The electrical connection must be performed in a dry place The cable glands in the connection bo...

Page 9: ...d At any rate the sum of the powers of the lights should remain below or equal to the power of the power Transformer power Max no of X30 50VA 1 100VA 2 300VA 7 Preferably use transformers sold in powe...

Page 10: ...e section SECTION mm 2 5 4 6 10 The drop in voltage in the power supply cable of the WPX30 must be limited so that the colours are not al tered Respect the table opposite one projector per cable Max l...

Page 11: ...Technical instructions WPX30 v2 0EN A Connection schematic www c cei fr 11...

Page 12: ...ectrique SAS FR47403521693 declares that the pro ductWPX30 meets the safety and electromagnetic compatibility re quirements of European Directives 2006 95 EC and 2004 108 EC Emmanuel Baret Marseilles...