CCI.TECU
– Operation
31
4.3.3.6
3-point hitch
This tab shows the voltage values for the maximum and minimum 3-point hitch
position.
You have the following operating options:
Calibrate
Note
Calibration is only possible for the active tractor. For all other tractors, the button
"Calibrate" (F3) is greyed-out.
4.3.3.6.1 Calibrate
Proceed as follows to calibrate the voltage values for the 3-point hitch:
1. Press the "Calibrate" button (F3) on the touchscreen.
→ The calibration menu opens.
2. Lift the 3-point hitch to the maximum position and then press on the "MAX"
(F3) button on the touchscreen.
3. Lower the 3-point hitch to the minimum position and then press on the "MIN"
(F4) button on the touchscreen.
4. Confirm the values with "OK"
Note
A plausibility check is performed. An error message is given if, for example, the
minimum value exceeds the maximum value.
Summary of Contents for CCI 50
Page 2: ...CCI 50 ISOBUS Terminal Operating instructions Reference Release 5 50...
Page 62: ...55 A Appendix Menu structure...
Page 64: ...CCI Cam Visual implement monitoring Operating instructions Reference CCI Cam v5...
Page 90: ...CCI Control Documentation and task management Operating instructions Reference CCI Control v4...
Page 196: ...107 10 Notes...
Page 199: ...110 Edit 38...
Page 200: ...CCI TECU Tractor data Operating instructions Reference CCI TECU v6...
Page 338: ...CCI GPS GPS settings and tractor geometry Operating instructions Reference CCI GPS v2...