RRS-4 Technical Manual 7/20/2011
3.1.1 Amps Tmrs
The “Amps Tmrs” button (Figure 6.7) navigates the operator to the screen previewed
below in Figure 7. Amps Tmrs allows the operator to make modifications to
install/remove amperages and timers that govern the CCM operation.
1.
Install Amps
– Sets the value for the maximum allowable drive motor running
current in the install direction
2.
Remove Amps
– Sets the value for the maximum allowable drive motor running
current in the remove direction
3.
Install TMR
– Sets the value for the maximum allowable time that the install
current can be greater than the set value
4.
Remove TMR
– Sets the value for the maximum allowable time that the remove
current can be greater than the set value
5.
Back
– Returns to CCM mode home
6.
Direction
– Navigates to the Install and Remove direction screen
Figure 8: Amps Tmrs modifications screen
1.
2.
3.
4.
5.
6.