QATRDM
|
Rev A
QAT-R-DM
– (M or H) ELECTRONIC TIME SWITCH
Installation and programming guidance
GENERAL
:
The programmable time switch can be used to automatically control pool pumps,
lights, geysers. etc.
Important Notes:
1.
The time switch has a backup power feature which requires 12 hours to fully charge.
(A fully charged time switch will retain its program and time for up to 24 hours, in the
case of a power failure).
2.
Pushing any button during a power failure will reduce the backup power period.
3.
CBI advises that the time switch be installed by a suitably qualified person.
ISOLATE POWER BEFORE INSTALLATION
●
Install the time switch on either mini rail or din rail with the clock screen up-right.
●
Wire the time switch according to
L
N
L
Time
Switch
L
N
L
N
(Load)
Appliance
Neutral
Bar
Figure 1: DB wiring
L
N
L
Time
Switch
L
N
L
N
(Load)
Appliance
Figure 2: Stand alone wiring
WARNING
: Do not connect more than 21A resistive or 10A inductive loads to the time switch
.
For loads larger than 21A resistive or 10A inductive, connect a suitable contactor to the time switch output.
Refer to
Figure 3
for connections.
L
N
L
Time
Switch
L
N
C
o
il
Contactor
L1 L2 L3
T1 T2 T3
Supply
Load
Figure 3: Wiring a contactor for loads greater than
21A resistive or 10A inductive.
TECHNICAL DATA
PRODUCT SPECIFICATION
Supply Voltage
Resistive load (Geysers, under floor heating, lights)
Inductive load (Pool pump, air conditioners)
Degree of Ingress Protection
Endurance
Operating Temperature
Reserve full charging time
Single segment period
Maximum period for all segments
Clock accuracy
230 V
RMS
50 Hz
Maximum 21 A
Maximum 10 A
IP41(Not waterproofed)
25 000 (minimum) Operations at maximum load
-20 °C to +55 °C
12 hours
30 minutes
48 x 30 minute segments
2 to 4 minutes per month
BOM:3990A640
Page 1 of 2