to connect the power supply. The product label
must not be removed as it contains important
information regarding the product.
All alarms to be connected in the house should
be put into ‘Learn Mode’ by sliding the switch on
the back of the alarm to the ‘Learn Mode’ position.
Please note: The learn switch placed on the back
of the alarm can only be in learn position when
the alarm is disassembled from the power supply
unit. The learn switch will automatically switch to
normal position when the alarm head is fitted to
the power supply.
The red LED will light up to indicate that ‘Learn
Mode’ has been selected.
Do not remove the battery during ‘Learn Mode’ as
this will interrupt the learn process.
Press and hold the test button at one alarm only,
until it beeps and the LED flashes. This alarm will
become the master and will start sending out a
specific house code to the other alarms.
As the other alarms receive the specific house
code, they will also flash the LED light.
When all alarms flash the red LED, they are
connected and can be switched out of ‘Learn
Mode’ and installed.
2.
THE BEST AREAS TO INSTALL THE SMOKE
ALARM:
• Note the local country regulations regarding
installation.
• Note the local regulations about information
to your insurance company regarding installed
smoke alarms.
• Install an alarm between possible fire sources
and bedrooms as a minimum.
• Install alarms on each floor of the house, in
hallways and stairways.
• Alarms in each room such as bedrooms and
living rooms.
Additional alarms increase the security.
3.
AREAS WHERE NOT TO INSTALL SMOKE
ALARMS:
• In dusty rooms
• At the top of a high pointed ceiling, in ceiling
corners, and within 50cm of a wall.
• In rooms where temperature goes outside the
range +4
o
to 38°Cor above 90% relative humidity
not condensing.
• In kitchens, garages, laundries, or too close to
fireplaces; areas where either dampness, gases
or smoke could occur.
Place the alarm where it is reachable in order to
test the alarm and for maintenance.
4.
PLACEMENT:
The smoke alarm is designed to be installed on
a ceiling.
With a minimum of one smoke alarm per floor and
a maximum distance between smoke alarms of
10 meters.
For ceiling installation:
The smoke alarm should be a minimum of 50cm
from the wall.
For cathedral or peak ceiling:
Mains powered smoke alarm device
Commercial reference: 2201-003
Developed by CAVIUS
The smoke alarm is designed for private homes.
PLEASE READ THE USER GUIDE
CAREFULLY BEFORE INSTALLATION AND
RETAIN FOR FUTURE USE.
TECHNICAL INFORMATION
The smoke alarm is powered by mains power
(110-230V AC), with a lithium back-up battery
CR2. Please note that you should only use batteries
from one of the following suppliers: DURACELL
or HUIDERUI.
It can be RF interlinked with other 2201 alarms,
and with other CAVIUS Wireless Family alarms.
The maximum number of alarms that can be inter-
linked within a house group are 32.
Please note: These must be alarms from the CAVIUS
The distance between interlinked alarms depends
on the house layout and they should always be
tested after installation. It is not advised to install
alarms with a separation of more than 10m.
Diameter: 97mm. Height: 41mm (without mount-
ing base) 52mm (with mounting base).
Interlinked by RF: 868 MHz
Complies to standards: EN14604:2005 + AC:2008,
EN300-220, EN50130-4:2011, EN60065.
EN60950-1, RoHs, Reach.
1.
HOW TO SET UP AND CONNECT ALARMS:
Start by pulling out the battery isolation
strip in the battery compartment
as shown.
Please note: RF connection is done with the
device powered with battery only. You do not have
UK
CHAMBER
FILTER
OPTIONAL HOLE
FOR LAMP WIRE
TEST BUTTON
SIREN
RED & GREEN LED
ISOLATION
STRIP
DO NOT
REMOVE THE
PRODUCT LABEL
1
NORMAL MODE
2
LEARN MODE
Minimum
1
1
2
Minimum 50cm
from wall
Wall
Ceiling
Peak ceiling
Minimum 50cm
from peak