Page 29/34
For more information please email [email protected] or call 1-(352)275-5319
6.3 Inspection/Cleaning of Water Inlet Strainer
The water inlet strainer and the water filter should be inspected before and after
each use of the CaviBlaster
®
2828-E60. To inspect and clean the strainer or filter,
follow the procedure below:
1) Turn the main power switch OFF and isolate or disconnect the water source
from the inlet connection to the power unit.
2) Unscrew the strainer bowl from the housing (turn CCW) (See Figure 6.1).
3) Pull the bowl down and remove the filter/strainer.
4) Inspect the filter/strainer and flush any debris clean with clean water.
5) Push filter/strainer back into housing and push the bowl back onto filter
housing.
6) Thread the bowl CW onto the housing nut to hand tighten.
7) Loosen and remove cap of main filter assy.
8) Lift filter media from housing and inspect for debris. Rinse or replace media
as necessary.
9) Inspect O-ring under the cap for damage. Replace cap and tighten.
Figure 6.1
– Inspection / Cleaning Water Filter/Strainer