Page 20/34
For more information please email [email protected] or call 1-(352)275-5319
2) Unroll sufficient length of hose to reach the operating location and connect
the gun to the high-pressure hose
3) Turn the E-Stop button and pull out to release (See Figure 5.1).
4) Turn the main power switch ON.
5) Turn the feed pump switch, SW2, ON and wait for the indicator light to turn
on.
6) Turn the HPP motor switch, SW1, ON and wait for the indicator light to turn
on. Note that the motor is equipped with a “soft start” starter and takes 3-4
seconds for the motor to start after being turned ON.
7) When the diver is ready to commence cleaning operations, ensure that the
system is properly and fully primed and the diver gun is submerged in water.
If the diver is not wearing a helmet, hearing protection is recommended.
CaviDyne
TM
suggests vented earplugs such as “Doc’s Proplugs” for diver
hearing protection.
8)
Wear neoprene or rubber gloves to protect the hands and follow all safety
regulations that may be applicable to the work being performed.
9) Pull the gun trigger to the open or ON position. (See figure 5.3)
10) The system is now ready to operate.
Figure 5.1
–Emergency Shut Down Switch On
DO NOT START THE MOTOR UNTIL THE DIVER IS
READY FOR UNDERWATER OPERATION.
Push on the red knob to
shut-down motor, twist and
pull the red knob out to
release motor shut-down.