4.2 Installation Location
For maximum flexibility the CaviBlaster
®
power unit should be installed in an area
where it is capable of reaching both its electric and water source and anticipated
cleaning targets within acceptable power cable and hose lengths. The
CaviBlaster
®
power unit can be installed in an enclosed* or open environment.
* Enclosed installations will require provisions for adequate motor cooling
air flow. See Figure 4.2 below.
Installation location must be a level surface able to safely support the unit weight
listed in Section 1.0
UNIT SPECIFICATIONS
. Orient unit to allow unrestricted
access to the hose connection plate and control panel, located on the front of the
unit. Allow a minimum of three feet behind the unit and access from above to
conduct service and repair work. Take note of frequently serviced areas such as
the in-line strainers and motor couplings.
Figure 4.2
– Installation Guidelines
Allow access to
control panel
Allow access
for general
service
Allow access
for general
service and
water
connection
panel
Grounding lug locations