7.0 WINTERIZATION
The power unit should be winterized if stored at temperatures below 32 degrees
Fahrenheit (0 degrees Celsius).
Total system displacement with 100 feet of hose (optional):
4.3
gallons
Total system displacement without hose:
2.0
gallons
To winterize the CaviBlaster
®
2040-D power unit:
1. Fill a 5 gallon or larger tank with appropriate antifreeze solution.
2. Insert a feed pump into the antifreeze tank.
3. Start the unit and make sure the pump is primed.
4. Attach a minimal amount of pressure hose and direct the outlet of the hose into
the antifreeze tank.
5. Run the unit without gun attached until antifreeze comes out of the end of the
hose for 10 seconds.
6. Stop the unit.
Following this procedure will ensure that all the critical system components exposed to
water have been flushed with antifreeze.