- 10 -
Dual-zone control panel:
Dual-zone temperature control system is characterized by dividing the cabinet into two
temperature control compartments (upper chamber and lower chamber) through
combination of circuit control system, sheet metal forming process and cooling system.
NOTICE:
It is strongly advised to maintain a difference of 7-8°C between the two
temperature zones in order to allow the temperature sensors to operate properly.
UPPER CHAMBER
Temperature control ranges from 5-12°C (40-54°F)
LOWER CHAMBER
Temperature control ranges from
12-22°C (54-72°F)
After the wine cooler is plugged in, if temperature is not set, the figure of temperature will be
marked automatically as 5°C (40°F) for upper chamber and 12°C (54°F) for lower chamber.
The last setting temperature will be memorized automatically by the system in the process of
normal operation in the event of power supply cutting.
After set temperature is locked, it will flash for 3 seconds, indicating the actual temperature
inside the cabinet. Afterwards, temperature inside the cabinet will reach the set temperature,
fluctuating around ± 2,5°C of set temperature which is regarded as normal.
SET (+/-)
Button for temperature setting.
Operate this button to control turn on/off LED lighting inside the cabinet.
Temperature setting for both upper and lower chamber is circulation type, setting can be
stopped when temperature reaches the target, the control system will have a reaction period
of 3 seconds, the corresponding digital display will flash. If temperature setting remains
unchanged for 3 seconds, the control system will assess and confirm the set temperature,
and then return to indication of actual temperature.