Quick Start Guide

S-Series | S32, S41 & 11R 

1. Wire Your Machine Control Unit

The MCU terminal and pin numbering of each relative to the OCU 
buttons are identified in the system configuration drawing provided 
with your system. 

1.

The implementation of an appropriate main line contactor power 
circuit is required using K18 and K19 to maintain the machine 
power and possibly K16 to reset the machine 

– can also be done 

via local reset.

2.

Connect power and ground (per system specification) to J1 via a 
local disconnect switch.

3.

If using an external antenna, make sure to turn the adjacent dip 
switch on.

4.

Check the wiring and turn on the MCU power. The MCU status 
LEDs two power green, Heartbeat flashing red and status amber 
will energize if all is OK , the relays K18 and K19 will energize 
when the OCU is linked. 

2. Install the Batteries

Rechargeable OCUs have tamper proof 
screws on the battery cover. Disposable 
battery (AA type) OCUs have cross head 
screws on the battery cover.

3. Turn On the OCU

1.

Press the ON button. The 
OCU will wake from sleep to 
a fully tested PASSIVE 

non-

transmitting mode.

2.

You will see all LEDs flash 
briefly.

3.

The center status and right-
hand LEDs 1 and 2 will then 
be illuminated.

ON

2nd

1st

4. Move to Active Mode

NB: S-Series OCUs must have completed the Association process with its target 
MCU (this only needs to be done once, see next page)

From Passive Mode, the OCU can be moved into Active mode. 

1.

Press the stop switch and then press the on switch within 3 seconds. 

2.

The status E-stop LED will now flash showing it is transmitting.

3.

The OCU is now operative, and the target machine will be under direct control. 

4.

To shut the system down Press the Stop Switch.

5.

If the OCU is left in Passive mode, it will power down after 3 minutes.

Nimble: 9M60-9061-A003-EN | May 2022

If using an external 
antenna, connect here 
and turn ON the adjacent 
DIP switch

K18

K19

RF 

Module

K16

FUSE