CaterSense CaterSense -01 Installation And Commissioning Instructions Download Page 1

 

CaterSense 

the Intelligent answer

 

 

CS-INST1-0.01 
Model: CaterSense 01  

Page 1 

07-11 

 
 

 
 
 
 
 
 

 

CaterSense -01 

 

 
 

GAS SUPPLY CONTROL with 

REMOTE CT MONITORING 

 
 
 

INSTALLATION and COMMISSIONING 

INSTRUCTIONS

 

Summary of Contents for CaterSense -01

Page 1: ...CaterSense the Intelligent answer CS INST1 0 01 Model CaterSense 01 Page 1 07 11 CaterSense 01 GAS SUPPLY CONTROL with REMOTE CT MONITORING INSTALLATION and COMMISSIONING INSTRUCTIONS...

Page 2: ...Cable entry 1 04 Electrical connections 1 05 System mode and set up locations 2 0 Set up and commissioning 2 01 Initial Set up 2 02 Mode Set up 2 03 Functional Operation 2 04 Troubleshooting 1 0 Gener...

Page 3: ...de at the bottom of the enclosure and lift off each side panel in turn by first pulling the bottom towards you This will reveal the four facia plate fixing screws 3 Unscrew these four screws and lift...

Page 4: ...Terminals 1 to 22 are the smaller terminals 1 5 mm cable and are used for the sensors inter locking devices remote speed and on off control Screen Cable must be used Terminals 23 to 34 are the larger...

Page 5: ...AL 240Vac SWITCHED FUSED POWER SUPPLY See Note 3 POWER SUPPLY N L E OUT GAS VALVE N L E LOCAL ISOLATOR See Note 1 GAS VALVE GAS VALVE OUTPUT WITH POWER SUPPLY FROM CATERSENSE CATERSENSE UNIT POWER SUP...

Page 6: ...rSense also has a unique Self set system commissioning tool which makes for easy system commissioning These devices are located on the left hand side of the main PCB under the side cover as detailed b...

Page 7: ...tailed on the wiring diagram for your installation b Input Jumpers Ensure that the correct input jumpers have been removed as detailed on the System Mode page for your installation c Sensor Links If y...

Page 8: ...provided from a volt free contact ensure that the contact is closed The system will produce a short beep Change the speed of the fans to the speed at which they draw maximum current THIS IS NOT NECESS...

Page 9: ...ws In the event of a system fault i e gas pressure fault fan failure knock off button depressed fire alarm detected the system must be reset by pressing SYSTEM STOP PRESS GAS VALVE GAS VALVE CLOSES Al...

Page 10: ...tput will be deactivated Solution Ensure remote knock off button has been released Check wiring to remote knock off button The system must be reset by pressing STOP b before it can be restarted 2 044...

Page 11: ...are clean Use the diagnosis mode to establish any problems with set up The system must be reset by pressing STOP before it can be restarted 2 048 EMERGENCY STOP Cause The system has been manually stop...

Page 12: ...S SAFE iii If in doubt ask contact us on or by any of the above iv Ensure that the client has been shown how to operate the system and that they have been handed the users guide TRENT PRODUCTS Trent H...

Reviews: