The Salvo Control Panel is designed as part of a safety system to prevent accidental drive aways. The Salvo Control Panel 
ensures that the loading bay door cannot be opened before the vehicle airline is disconnected via the Salvo Susie coupling 
and the key has been transferred from the coupling to the SCP

+

.

1

2

3

SCP

+

 with bay controls 

isolated, ready to receive key.

Insert key and turn clockwise.

SCP

+

 with bay controls 

energised, ready to open door 
and deploy dock leveller.

U-Salvo-2013-E Issue 1

15

Salvo Control Panel (SCP

+

)

User Guide

The Salvo Control Panel Plus (SCP

+

) is the main interface between 

the Salvo couplings and associated bay door controls. The SCP

+

 

comprises of a wall mounted panel with easy to use Castell 
interlock key switch to allow operation of the bay. There is also 

panel indication of status and operation. Installation is via plug in 

terminals on the internally mounted PCB.

SCP

+

Temperature (Operating)

Min: -25°C, Max: +55°C

Size

300mm(H) x 220mm(W) x 157mm(D) (172mm with Mounting) 

Mounting Hole

160mm(H) x 140mm(W) (Mounting Plate) – M8 Fixings
260mm(H) x 160mm(W) (Enclosure) – M8 Fixings

Material

Enclosure – Mild Steel to BS 1449 HR4
Lock Portion – Stainless Steel 304/316

Weight

5.5 kg

Cable Entry Size

M20 x 2

Switch Approvals

IEC947-1.3 IEC947-5 BS EN60947 VDE 0660

UL Listed

TBA

Ingress Protection

IP55 Enclosure

Switch Rating

Continuous, unattended, remote

Power Supply Required

24VDC

Max Power Consumption

20VA / 20W

Power Frequency

50/60Hz

Relay Specification

Max switching voltage 240VAC 6A
Max switching current 6A

Operation

Specifications

Summary of Contents for Salvo SCP+

Page 1: ...a wall mounted panel with easy to use Castell interlock key switch to allow operation of the bay There is also panel indication of status and operation Installation is via plug in terminals on the in...

Page 2: ...boards ensure you dissipate your body s charge Operation Maintenance WARNING Disconnect Electrical Supply Before Opening Unit Never operate this unit with the access door open Never place any body pa...

Page 3: ...anager 2 Mount SCP Depending on site conditions Ideally the SCP should be mounted 1 5m above floor level If mounted outside the building it should be mounted beneath the traffic lights If mounted insi...

Page 4: ...f green traffic light 10 8 connect to ve terminal of both red and green traffic light 4 2 Install SPSB Mounting Holes 90mm H x 94mm W SPSB M5 Fixings Connections Connector 1 Terminals 1 2 3 SCP 1 Conn...

Page 5: ...outside warehouse on pedestal Installation 3 4 Our standard 24V door locks are to be used re SADL Connect to terminal 1 2 3 4 of Connector 2 and terminal 10 of Connector 8 Connector 2 terminal 1 conne...

Page 6: ...a failsafe device therefore if there is a failure then the door cannot be opened 7 Connect Dock Leveller Control Interface It may be necessary to prevent activation of the dock leveler when the door...

Page 7: ...DC 6A 1 5mm Beacon N O contacts to control beacon 24VDC 6A 1 5mm Aux 1 Change over contacts to control other peripherals 6A 1 5mm Function Condition Key Free Door de activated SADL de energized Traffi...

Page 8: ...U Salvo 2013 E Issue 1 22 Salvo Control Panel SCP User Guide Wiring Diagram...

Page 9: ...Order Information Please advise part number and symbol when ordering mandatory information Part Number Symbol 007007 please advise U Salvo 2013 E Issue 1 23 Salvo Control Panel SCP User Guide...

Reviews: