background image

R-39

QT-6000 Reference Manual

2-3-2.

Remote printer control setting

Remote printer settings:

After changing the DIP switch configuration, remote printer initialization (power on by
pressing the <LF> key) is necessary.

SW No.

Function

Data reception error
Receive buffer capacity
Handshaking
Data word length
Parity check
Parity selection

Transmision speed

ON

OFF

Ignored

Prints "?"

45 bytes

4k bytes

XON/XOFF

DTR/DSR

7 bits

8 bits

Yes

No

Even

Odd

See transmission 

speed setting

Density setting

Light

Dark

SW No.

3

ON

OFF

ON

OFF

4

ON

OFF
OFF

ON

UP-350 Bottom view

DSW1

DSW2

1
2
3
4
5
6
7
8

1

SW No.

Function

Busy condition

Reserved

Print density

Reserved
Reserved
I/F 6 pin reset signal
I/F 25 pin reset signal

ON

OFF

Buffer full

Buffer full

or Offline

Fixed

See density setting

Fixed

Fixed

Enabled

Disabled

Enabled

Disabled

1

2
3
4
5
6
7
8

2

Transmission
speed setting

bps

2400
4800
9600

19200

SW No.

7

ON

OFF

ON

OFF

8

ON
ON

OFF
OFF

SW No.

Function

Data reception error
Receive buffer capacity
Handshaking
Data word length
Parity check
Parity selection
Baud rate

Busy condition

ON

OFF

Ignored

Prints "?"

40 bytes

1k byte

XON/XOFF

DTR/DSR

7 bits

8 bits

Yes

No

Even

Odd

4800 bps

9600 bps

Buffer full

Buffer full

or Offline

1
2
3
4
5
6
7

8

1

SW No.

Function

No. of digits
(7x9 font / 9x9 font)

Internal use
#6 pin reset signal
#25 pin reset signal

ON

OFF

42 / 35

40 / 33

digits

digits

 

 

Enabled

Disabled

Enabled

Disabled

1

2
3
4

2

Select this option.

UP-250

Dip switch is located at the bottom of the printer.

UP-350

SW No.

Function

Reset by DTR
reserved
Protocol

Transmision speed

Parity

undifined
Low power comsumption
undifined

ON

OFF

Yes

No

---

fixed

DTR/DSR

XON/XOFF

See transmission 

speed setting

See paritysetting

---

---

Yes

No

---

---

SW No.

7

OFF

ON

OFF

ON

UP-360 Bottom view

1
2
3
4
5
6
7
8
9

10

1

Parity setting

Non

Even

Odd

Non

6

OFF
OFF

ON
ON

Transmission
speed setting

bps

4800
9600

19200
38400

SW No.

4

OFF
OFF

ON
ON

5

OFF

ON

OFF

ON

UP-360

Dip switch is located at the bottom of the printer.

Summary of Contents for QT-6000

Page 1: ...QT 6000 Touch Screen Smart Terminal Reference Manual Version 1 5 October 2006 c ...

Page 2: ...istrations in the RF or REG mode 7 Read and reset This chapter explains detail of the read and reset operations and reports 8 Appendices These chapters show the record format and descriptions of individual files total calculation method meaning of error messages etc System down and recovery in the Installation and Down Recovery manual Thischapterexplainsactionstotakeandrecoverymethodswhenthesystem...

Page 3: ...le terminal With the QT 6000 system any terminal has the same function and can be designated as the master terminal by programming 2 Software concept A flexible application system for development adopting the following methods Function classified application system 3 Terminal hardware concept Color LCD with touch panel In addition to the above the QT 6000 is also a terminal following characteristi...

Page 4: ...tallation or after a longtime vacation over 30 days Before installation initialize the terminal and leave it turn on over 12 hours After a longtime vacation initialize the terminal and restore the program data if the terminal is in malfunction and leave it turn on over 12 hours Over 48 hours charging makes the batteries fully charged ...

Page 5: ...ual function keys R 29 2 2 1 System keys R 29 2 2 2 Finalize keys R 30 2 2 3 Transaction keys R 30 2 3 Remote printer control R 38 2 3 1 Remote printer system configuration R 38 2 3 2 Remote printer control setting R 39 2 3 3 Remote printer output control R 40 2 3 4 Remote printer backup processes R 40 2 4 Check tracking system R 43 2 4 1 Shared check tracking system R 43 2 4 2 Shared check tracki...

Page 6: ... Solution to abnormality of satellite terminal R 66 2 11 4 Sign on compulsory R 66 2 12 IDC Item Data Capture R 67 2 12 1 Available capturing items R 67 2 12 2 Set up the IDC start end R 70 2 12 3 How to memorize the captured items R 71 2 12 4 IDC data file structure R 72 2 12 5 IDC data type R 76 2 12 6 Transferring IDC R 77 2 13 Electronic journal R 78 2 13 1 Storing electronic journal R 78 2 13...

Page 7: ...te power control R 102 3 5 Data Communication System R 103 3 5 1 Inline online connectors R 103 3 5 2 Hardware interface R 104 3 5 3 Inline online functions R 106 3 6 Collection Consolidation system R 107 3 6 1 X Z collection R 109 3 6 2 X Z consolidation R 111 3 6 3 X Z collection consolidation R 113 3 7 Auto programming function R 116 3 7 1 Auto programming functions R 116 3 7 2 Auto program ope...

Page 8: ...4 16 Mix match coupon R 137 4 17 Customer R 138 4 18 Table sharing R 138 4 19 Order character change R 138 5 Refund mode operation R 142 5 1 Selecting REF or REG mode R 142 6 Read and reset operations R 144 6 1 The procedures of reading or resetting R 144 6 2 Report sample R 146 Appendix 1 Function key list R 160 Appendix 2 File format R 164 Appendix 3 Counter and Totalizer calculation method R 19...

Page 9: ...Hardware configuration R 10 1 1 General configuration R 10 1 2 Hardware diagram R 11 1 3 Keyboard R 12 1 4 Display R 13 1 5 Cash drawer R 14 1 6 Input output connectors R 15 1 7 Optional peripherals R 16 1 8 System configuration R 17 ...

Page 10: ...re optional devices and configurations of the QT 6000 system 1 1 General configuration Touch screen panel Display on off key Pilot lamp i Button key receiver only for QT 6000 DLS Microphone Stand Card slot cover Power switch cover Panel fixing screw Connector cover Front view Rear view ...

Page 11: ...pply AD31U E PRT CB 8A 8B Power supply PS 180 Power supply Remote printer UP 250 PRT CB 8A 8B Power supply PS 180 Remote printer UP 250 Microphone Speaker i Button key i f CF card Card slot cover 800 x 600 dot color LCD Max 95 key touch screen Wireless LAN card HUB Other terminals MCR QT 6046MCR AC Adptor ADP820A Drawer 2 i f Drawer 1 i f Inline RS 232C COM1 RS 232C COM2 RS 232C COM3 RS 232C COM4 ...

Page 12: ...0123456789012345678901234567890 1234567890123456789012345678901234567890 1234567890123456789012345678901234567890 1234567890123456789012345678901234567890 1234567890123456789012345678901234567890 1234567890123456789012345678901234567890 1234567890123456789012345678901234567890 1234567890123456789012345678901234567890 1234567890123456789012345678901234567890 1234567890123456789012345678901234567890...

Page 13: ...t Cut off Master or BM ß Double size ª Standard size π Items sold Total amount Current transaction amount change Scroll area Mode Clerk Date Time Consecutive number PLU010 PLU020 PLU030 PLU040 PLU050 PLU009 PLU019 PLU029 PLU039 PLU049 PLU008 PLU018 PLU028 PLU038 PLU048 PLU007 PLU017 PLU027 PLU037 PLU047 PLU006 PLU016 PLU026 PLU036 PLU046 PLU005 PLU015 PLU025 PLU035 PLU045 PLU004 PLU014 PLU024 PLU0...

Page 14: ...reen lead on drawer to the terminal Mount the cash register 1 Screw in 2 fixing screws bottom side of the terminal 2 Mount the terminal on the top of the drawer ensuring that the feet on the bottom of the terminal go into the holes on the drawer Dark Bright 1 4 4 Main display brightness control 1 4 3 Menu level display part contents SHIFT PLU 1 Menu shift 1 2nd Shift PLU level 1 8 Menu sheet 1 15 ...

Page 15: ...tput connectors Inline connector COM port and drawer cable are located in the backside connector cover DC IN PC MODEM SCANNER DISPLAY DRW1 DRW2 COM1 COM4 COM2 COM5 COM3 COM6 SPK MIC LAN1 VOL COM1 COM4 COM2 COM5 COM3 COM6 From the AC adaptor Inline 10 100Base T Sound volume control Drawer 2 Drawer 1 Ext microphone Ext speaker Bottom side of the terminal ...

Page 16: ...nd slip printer connect slip to COM 4 port If you connect the slip printer to COM 4 the automatic detection during INIT does not performed You muse program the I O parameter manually 4 Remote display RS 232C COM 3 port QT 6060D 5 Remote printer UP 350 360 UP 250 RS 232C COM 4 6 port The remote printer is used for reports kitchen orders receipts 6 Inline Inline port You can use CAT5 UTP cable 7 Dra...

Page 17: ... check tracking system and floating clerk interrupt system This terminal also has check index and detail files and update them at the same timing of master When the check master goes down the backup master plays the role of check master 3 Check self master Check self master has its check tracking system files and clerk interrupt files for itself 4 Satellite The terminal which is not assigned to 1 ...

Page 18: ...M CHK BM PRN 1 PRN 2 PRN 3 Order Order PRN 1 PRN 2 PRN 1 PRN 2 PRN 3 Order Order Order Up to 8 remote printers Order Order Order CHK M CHK BM PRN 1 PRN 2 PRN 3 Order Order Order PRN 1 PRN 2 PRN 3 Up to 6 remote printers Slip Peripherals ECR definition Remote Slip PC printer printer MODEM Check master Check backup master Self master Satellite Check Check Self Terminal ECR definition master backup m...

Page 19: ...ss Maximum 32 terminals 1 8 2 Inline collection consolidation system Inline collection consolidation and auto programming for up to 32 terminals 1 8 3 Online collection consolidation system Online collection consolidation and auto programming for up to 32 terminals PC on line Note Maximum 3 remote printers in the 1 terminal system 6 remote printers 2 terminal system 8 remote printers in the 3 32 t...

Page 20: ...R 20 Hardware Configuration ...

Page 21: ... 4 2 Shared check tracking requirement R 44 2 4 3 Data backup when the master goes down R 44 2 5 Other check tracking system control R 45 2 5 1 The timing to clear check detail and index file after finalization R 45 2 5 2 Table transfer R 45 2 5 3 Store and recall R 45 2 6 Clerk control function R 47 2 6 1 Clerk interrupt R 47 2 6 2 Clerk detail memory R 48 2 6 3 Clerk training R 48 2 6 4 Manager ...

Page 22: ... Available capturing items R 67 2 12 2 Set up the IDC start end R 70 2 12 3 How to memorize the captured items R 71 2 12 4 IDC data file structure R 72 2 12 5 IDC data type R 76 2 12 6 Transferring IDC R 77 2 13 Electronic journal R 78 2 13 1 Storing electronic journal R 78 2 13 2 Issuing electronic journal report R 78 2 13 3 Displaying electronic journal and producing guest receipts after sales R...

Page 23: ...2 files have 200 order file numbers These files can be reset individually and separately from the terminal files This provides access to weekly and monthly total data The periodic total 1 files and 2 files have the same functions and can accumulate data with different periods The same numberofrecordsasthecorrespondingterminalfilemustbereservedforeachperiodic total files Consolidation files Consoli...

Page 24: ...otalizers Registered data is accumulated to totalizers which are reserved for each functions The QT 6000 has the following types of totalizers 1 Fixed totalizers Registration data is accumulated for individual terminals 2 Function key totalizers Data input by finalize or transaction keys is accumulated in totalizers for each key Operation types as well as data used in operation differ depending on...

Page 25: ...idual function keys are found in the chapter 2 2 2 1 4 Keyboard layout Normally the keyboard is assigned functions which are required for registration of transactions The keyboard is also used for character input when entering descriptors or names during programming The QT 6000 automatically switches the keyboard to its character input function when it determines that character input is required f...

Page 26: ...termine the status of the terminal or the required subsequent action 2 1 6 1 Operation prompt Refertothepage201ofthismanualfordetails Thesemessagescannotbeadded modified or deleted 2 1 6 2 Error messages Refer to the page 198 200 of this manual for details Error messages are displayed to indicatethatanerrorhasoccurredandacompulsoryoperationmustbeperformed Allerror messages cannot be added modified...

Page 27: ...s for the above listed keys Also some of these keys can be programmed as validation compulsory this means that registration is not permitted until the validation of the former registration has been performed Item validation is performed directly following an item registration listed below Departments Subdepartments PLUs You can program the multiple validation printing status for above items Descri...

Page 28: ...lly released If the paper is not released for some reasons press SLIP FEED RELEASE or SLIP BACK FEED RELEASE to release the paper Before using slip printer you should program the maximum lines of slip The following two sections are other features to control slip printing format 2 1 7 4 Endorsement message print control The QT 6000 allows printing of endorsement messages on the slip printer SP 1300...

Page 29: ...ey must be allocated on the keyboard 3 Home position key This key is used for returning cursor to the home position 4 Left right up down arrow keys These keys are used for moving the cursor 5 Yes key This key is used for consenting the selection and proceeding steps 6 No key This key is used for cancelling the selection and proceeding steps 7 Mode key This key is used for changing modes of the ter...

Page 30: ... Normally a receipt is issued Programmability Refer to page 84 of the programming manual 2 2 3 Transaction keys Each of the transaction keys have programmable functions which may be used as required The general description of each transaction key with individual options is outlined on the following sections 1 Price inquiry key Function code 008 This key is used to confirm the price and descriptors...

Page 31: ...t 2 Specifying sub currency while entering an amount for payment Programmability Refer to page 87 of the programming manual 13 Pick up key Function code 022 When sales receipts are removed from the drawer or when the amount in drawer exceeds the limit value sentinel function the manager performs a pick up operation This key is used for this function This operation affects media totals rather than ...

Page 32: ...tion can be prohibited for certain function keys 24 Receipt key Function code 038 Thiskeyissuesareceiptforthelasttransaction post finalizationreceipt whentheoriginal receipt is not issued This key also issues a guest receipt The guest receipt can be designated by seat number Programmability Refer to page 91 of the programming manual 25 Check endorsement key Function code 039 This key is used to pr...

Page 33: ...the programming manual 37 Slip back feed Release key Function code 054 This key is used to back feed slips inserted into the slip printer This is done by specifying the number of feed lines This key is also used to release the slip paper holder if numbers are not entered 38 Slip print key Function code 055 This key is used to execute a slip batch printing on the slip printer Pressing this key prin...

Page 34: ...nit price 50 Second unit price key Function code 070 This key is used to register a specific item at the second unit price 51 Clerk number key Function code 072 This key is used to assign a clerk s secret number Programmability Refer to page 95 of the programming manual 52 Operator read reset key Function code 073 This key is used to issue a clerk s individual X Z report Programmability Refer to p...

Page 35: ...lity Refer to page 98 of the programming manual 65 Old check key Function code 092 This key is used in a check tracking system to input the number of an existing check previously created by the New check key whose details are stored in the check tracking memory Existing checks are reopened to perform further registration or to finalize them Programmability Refer to page 99 of the programming manua...

Page 36: ...m press this key again then the appropriate window will be opened to fix it 77 Round repeat key Function code 116 This key is used to register the same items which were ordered just before Programmability Refer to page 98 of the programming manual 78 Open check key Function code 117 This key is used to issue an open check report of an assigned clerk Programmability Refer to page 96 of the programm...

Page 37: ... used to declare the following transactions as payment 93 Electronic journal display key Function code 207 This key is used to display the stored journal 94 Display mode key Function code 219 This key is used to change display modes normal mode item consolidation mode 95 Cancel key Function code 236 Invalidates all preceding data registered for departments PLUs and set menus within a transaction T...

Page 38: ... 3 Remote printer control Up to eight printers for printing kitchen orders etc 2 3 1 Remote printer system configuration Please refer to page 17 for the system configuration The printing processing of the remote printer is performed as shown in the figure below 1 A transaction is made at a terminal 2 The terminal sends printing data to the terminal with remote printer 3 The terminal with remote pr...

Page 39: ...0 19200 SW No 7 ON OFF ON OFF 8 ON ON OFF OFF SW No Function Data reception error Receive buffer capacity Handshaking Data word length Parity check Parity selection Baud rate Busy condition ON OFF Ignored Prints 40 bytes 1k byte XON XOFF DTR DSR 7 bits 8 bits Yes No Even Odd 4800 bps 9600 bps Buffer full Buffer full or Offline 1 2 3 4 5 6 7 8 1 SW No Function No of digits 7x9 font 9x9 font Interna...

Page 40: ...Remote printer error or terminal with remote printer error In case of the backup printer is assigned when the terminal which sends printing data to remote printer detects the remote printer or the terminal with remote printer abnormality the remote printer cross backup see the next section is made In case of no backup printer isassignedorthebackupprinterisalsodowned thedatawillbeabletoprintonthein...

Page 41: ...ingle bon double bon Soft Drinks Single Bon CHECK NO 123456 MC 01 REG C01 15 12 2003 12 34 001234 1 Lemon Tea Cut or print dot line Soft Drinks Double Bon CHECK No 123456 MC 01 REG C01 15 12 2003 12 34 001234 2 Coffee STUB Double Bon message Soft Drinks Order character CHECK No 123456 MC 01 Check number Machine ID REG C01 15 12 2003 12 34 001234 Mode Clerk Date Time Consecutive No 2 Coffee 3 Order...

Page 42: ...EG C01 15 12 2003 12 34 001267 2 Steak Set Set menu 2 Medium Detail item 2 Salad 1 Pizza Main item 1 Soft Preparation 1 Cheese Condiment 1 Tomato 1 Pizza Main item 123456 Main item PLU No 1 Soft Preparation with quantity PLU No 000001 1 Cheese Condiment with quantity PLU No 000002 1 Tomato 000003 ...

Page 43: ...performed for multiple terminals connected to inline This means that any terminal can be used to recall a temporary closed check of one s cluster for additional registration or finalization System configuration 1 cluster system System configuration multi cluster system Order Order Up to 12 QT 6000 terminals cluster Up to 12 QT 6000 terminals cluster CHK M CHK BM CHK M CHK BM PRN 1 PRN 2 Order Orde...

Page 44: ...inarily registered items or functions per one table If the number of items or functions exceeds this value during registration the next block is used automatically for the following transactions Number of item blocks Ordinarily theregistrationrequiresoneitemblocks butinapartyforexample more items are registered per one table So it is necessary to define how many item blocks can be used The maximum...

Page 45: ...status of the transferring check 1 If the transfer check is not used The entered check number is written 2 The check number is already used Add the contents to the existing contents This option is set on the page 86 of the programming manual 2 5 3 Store and recall These functions are used for the driving through purchase The check number used in store operation is defined by check No range program...

Page 46: ...report is printed out the check No range will be reset After this operation the next check No by using Store function will be the range start Thisfunctionworkswiththeoption ClearingCHK TBLNo byusingthesamenumber again to Check number only Refer to page 40 of the programming manual R J Entrance Exit Temporary receipt Order receipt Receipt KITCHEN Store Recall Hamburger French Fries Hot Coffee CHK N...

Page 47: ... allow the clerk interrupt function which makes it possible for multiple clerk to simultaneously use the same register If a clerk starts registration of a transaction another can be interrupt the original registration and begin a new one The original clerk can later resume the interrupted original registration You can use the clerk interrupt function with the check tracking function Notes 1 Error ...

Page 48: ...re controlled exactly the same way as a working clerk 3 Receipts are different from those normally used The training receipts are filled with training filler default 4 Only the REG REF REG mode can be used for training 2 6 4 Manager mode control There is no actual REG 2 mode on the terminal but you can control some functions you want under manager control Preparation for this function 1 Set NO to ...

Page 49: ...ion in this example void opera tion 5 Pressing the REG MODE key is required when the manager returns his her office REG C01 10 10 01 12 34 000001 1 PLU0001 10 00 1 PLU0002 20 00 PLU0003 30 00 2 30 00 REG C01 10 10 01 12 34 000001 1 PLU0001 10 00 1 PLU0002 20 00 1 PLU0003 30 00 REG2 Mode 0 00 3 60 00 REG C01 10 10 01 12 34 000001 1 PLU0001 10 00 1 PLU0002 20 00 REG Mode 0 00 2 30 00 ...

Page 50: ... arrangement file Multiple arrangement keys can be preset on the keyboard and each key can be linked to an arrangement program The linked arrangement program is then called and executed by pressing the arrangement key The following table shows the command parameters of the arrangement key function that can be interpreted and executed by the QT 6000 Command parameters can only be separated by space...

Page 51: ...mber Used for ordinary function keys The numbers can be specified for zero suppression Note The arrangement key itself cannot be programmed for in an arrangement program 3 Mode setting Any mode key can be specified for an arrangement key function function code mode definition Used for mode keys Note 121 01 REG mode 121 02 REF mode 121 03 REG mode 122 01 X Z mode 122 02 MGR mode 122 03 Collection C...

Page 52: ... in the buffer is larger than the specified number the command execution flow jumps and continues from thepointpresetbythelabel Iftheconditionisnotmatch with the above mentioned condition the step advances to the next command I number label This is a conditional jump command If the value in the number entry buffer is less than the specified number the command execution flow jumps to the point pres...

Page 53: ... Set the default menu sheet number to n n 0 2 and stay down menu sheet assignment of all clerk CLMn Set the default menu sheet number to n n 0 15 and stay down menu sheet assignment of all clerk CLSn Set the default shift PLU level number to n n 0 8 211 Press the ESC key 212 Press the YES key 213 Press the NO key GET Read from key buffer PUT Write to key buffer CLL0n Set the default clerk pop up w...

Page 54: ...d number to the parameter save area 202 0031 Press Clear button 1111100000000 Input the operation code for system command PUT Pick up the entered number from the parameter save area KNO2 Specify the 2 key for entering the operation code 211 0045 Specify the ESC key to execute this operation ERR1 When the input number is not 1 to 9 the following commands are processed E End the program mandatory 2 ...

Page 55: ...ls Printing sample QT 6000 TERMINAL GRAPHIC LOGO AREA COMMERCIAL MESSAGE LINE 1 COMMERCIAL MESSAGE LINE 2 COMMERCIAL MESSAGE LINE 3 COMMERCIAL MESSAGE LINE 4 2 8 2 Making graphic logo procedure Before following this procedure please allocate Graphic logo file file 047 on the terminal 1 Making a bit map image file 432 104 or 432 208 pixels 1 bit color for UP 350 UP 360 2 Convert this bit map file t...

Page 56: ...moreover specify the cycle time that indicates an unit of the appropriate intervals Hourly item link file This file is used to record the Hourly item which links with the appropriate time zone You can also specify the particular totalizer for each time zone Hourly item This file is used to store the contents of the quantity and amount of each registered item The following seven files enable to lin...

Page 57: ...riod works in conjunction with the schedule If the scheduler is not being utilized then the grace period inputs indicated below become inactive Grace period before start time this input indicates how many minutes an employee may clock in before the scheduled clock in time Grace period after start time this input indicates how many minutes an employee may clock in after the scheduled clock in time ...

Page 58: ...tions of the file Employees job assign This function is used to assign a job to each employee Before assigning the job be sure to program the details of the jobs Every employee file can link to some job code files maximum 4 jobs so some employees may link to the same job code file But be sure to make individual job files if the employees work under different hourly wages Job 1 Job 2 Job 3 Job 4 Jo...

Page 59: ... First week First week First week Second week Second week Second week Monday Monday Monday Tuesday Sunday Monday Monday Monday Sunday Monday Monday Monday Tuesday Sunday Monday Monday Monday Shift 1 Shift 2 Shift 3 Shift 1 Shift 3 Shift 1 Shift 2 Shift 3 Shift 3 Shift 1 Shift 2 Shift 3 Shift 1 Shift 3 Shift 1 Shift 2 Shift 3 Employee 1 Employee 2 Employee 3 Employee 4 Employee 1 Employee 1 Employe...

Page 60: ...UT 2 10 2 Clock in operation This function is used to register the Starting work time 2 10 2 1 Clock in operation 1 Program Not using the window and impossible to specify job code Allow to specify job code NO Display job code window NO Refer to the page 54 of the programming manual Operation 1 XXXXXX CLOCK IN When this message appears press the YES key to register the start of working hours XXXXXX...

Page 61: ...its XXXXXX YY 2 10 2 3 Clock in operation 3 Program type Display job code window YES Allow to clock in with non preset job code NO Refer to the page 54 of the programming manual Operation 1 XXXXXX CLOCK IN 2 ChoosetheappropriateJobCodefromtheCLOCK INmenu and press the YES key to register the start of working hours Job codes that are programmed in Employee file are displayed XXXXXX REG 10 10 01 11 ...

Page 62: ...working hours All job codes that are programmed in job code file are displayed XXXXXX Receipt sample MC 01 Header REG C01 12 31 2005 11 59 AM 001234 Harrison Employee character 16 digits CLOCK IN 11 59 AM Special character REC 29 time JOB Dish Washier Special character REC 33 job character If you want to change these special characters refer to the page 112 of the programming manual REG 10 10 01 1...

Page 63: ...s impossible to close the accounts Receipt sample MC 01 Header REG C01 12 31 2005 11 59 AM 001234 Harrison Employee character 16 digits CLOCK IN 11 59 AM Special character REC 29 time JOB Dish Washier Special character REC 33 job character CLOCK OUT 01 59 PM Special character REC 30 time WORK TIME 02 45 Special character REC 34 working hours BREAK TIME 00 45 Special character REC 35 recess CASH TI...

Page 64: ... appears press the YES key to register the end of a recess The receipt is not printed out except electronic journal 2 10 3 5 Manager operation When the manager operate CLOCK IN after signing on the manager can operate and modify any employee s record despite of corresponding employee number Following operations are possible to operate by the manager Specify the job code CLOCK IN CLOCK OUT BREAK IN...

Page 65: ...ll the terminals Be sure there is a clerk who is specified as Manager in the clerk file If no manager it may be locked to operate 2 11 1 Sign on 1 When an employee normally operate CLOCK IN OUT BREAK IN OUT the employee s attendance information is sent from the main terminal to the satellite terminals Flow of sign on Sign on OK CLOCK IN CLOCK IN unfinished Unable to Sign on E175 Error message appe...

Page 66: ...his case only manager can sign on When the satellite terminal could receive the CLOCK IN OUT information from the master terminal only once but failed to receive after then the CLOCK IN OUT informationineachsatelliteterminalhasleftinthelastreceivedcondition Insuchcase thelastreceivedinformationcontrolemployees signon off Managercanalwayssign on 2 11 4 Sign on compulsory When the satellite terminal...

Page 67: ... file 2 12 1 Available capturing items Select the appropriate items that should be captured and program these items into the IDC link file The available items and their contents are indicated below Items Contents File No PLU Subdepartment Department Function Pulldown group Clerk 004 003 005 002 026 007 The index of the transaction The report of all the detailed statements The index of the transact...

Page 68: ... price 1 069 O Second unit price 7 070 O Clerk number 5 072 O Operator read reset 073 Tray total 13 074 O Subtotal 8 075 O Receipt On Off 076 Taxable amount subtotal 077 Operator number 078 Merchandise subtotal 8 080 O Food stamp subtotal 081 Multiplication 1 082 O Quantity For 1 083 O Square 1 084 O Selective item subtotal 2 085 O Cube 1 090 O New check 091 Old check 092 New Old check 093 Add che...

Page 69: ...n header record 6 This function itself is not captured But the functions that are executed by this function are captured 7 This function is not captured But item itself might be an IDC target 8 When the option printed when the key is pressed is selected it is captured 9 Transferred items by the add check and the separate check are not captured 10 ST transfer is not captured 11 This function is cap...

Page 70: ... can restart IDC by performing FC or INIT 2 Refer to the page 10 of the programming manual Operation Note 1 If you stop the IDC when the IDC file is full of items you can stop the error sound without clearing any registered data 2 The necessary files for IDC File 036 Registration buffer File 063 IDC buffer File 057 059 IDC file File 804 IDC link file Item Data Capture Item Data Capture YES 0 00 ...

Page 71: ...r PLU 0002 Header PLU 0003 Header Total PLU 0001 PLU 0002 PLU 0003 Total IDC Buffer IDC file 1 Header PLU 0002 Header PLU 0003 IDC file 2 2 Program Store data Item only refer to the page 56 of the programming manual When an appropriate item is selected this item and the header will be captured see the illustration below Example PLU 0001 Memorized into IDC file 1 PLU 0002 Memorized into IDC file 2 ...

Page 72: ...ated this check D5 D4 Clerk last opened this check D3 D2 Clerk opening this check D1 Payment D2 00 Non payment 01 Payment D1 Item Item PLU Subdepartment Department Function Cash Charge Check Credit Rec 1 CE key Rec 0 3 7 9 14 19 24 29 30 Type Tendering amount in local currency 1 03 50 Tendering amount in foreign currency Mc ID Total Amount Change Amount Totaling Type Not Used 5 File 1 2 File 1 Gro...

Page 73: ...t Text recall 0 3 5 47 File 1 1 03 Mc ID 50 Character Not Used Type 2 7 Rec 1 2 Table transfer Tip 03 Mc ID Not used ST Original check Rec 1 Type 2 New check 0 5 7 12 50 1 3 File 1 18 24 2 03 Mc ID Not used Amount Rec 1 Type 2 0 5 7 12 50 1 3 File 1 2 1 4 Refer to the last page of this section 03 Mc ID Not used Amount Rec 1 Type 2 0 5 7 12 50 1 3 File 1 2 Received on account Paid out Deposit Loan ...

Page 74: ...sed Rec 1 Type 2 0 5 7 12 50 1 3 File 1 14 2 Tax exempt Taxable amount 4 Taxble amount 1 Taxable amount 2 Taxable amount 3 Taxable amount 5 Taxable amount 6 TAxable amount 7 0 03 Mc ID Rec 1 Type 2 Not Used 3 5 9 14 19 24 29 1 50 34 7 File 1 39 2 Tax status 3 44 Field name Taxable Taxable Taxable Taxable Taxable Taxable Taxable Tax system amount 1 amount 2 amount 3 amount 4 amount 5 amount 6 amoun...

Page 75: ...2 Type It means record type refer to 2 12 5 IDC data type section of this manual 3 Tax status Single tax VAT b1 T S1 b2 T S2 b3 T S3 b4 T S4 b5 T S5 b6 T S6 b7 T S7 b8 T S8 b9 T S9 b10 T S10 U S or Singapore b1 T S1 b2 T S2 b3 T S3 b4 F S Canada b1 T S1 b2 T S2 b3 T S3 b4 T S4 b9 Donuts tax 4 Item status b6 not used b5 2nd registration b4 house Bon registration b3 COUPON2 registration b2 REFUND re...

Page 76: ...BLTR 52 NB table transferring operation DTLTYPE_CANCEL 55 Cancel DTLTYPE_TBLTR 56 Table transfer DTLTYPE_NBFEE 57 NB fee DTLTYPE_STORE 58 Store DTLTYPE_ST_PLUS 64 ST DTLTYPE_ST_MINUS 65 ST DTLTYPE_ST_CPN 66 ST CPN DTLTYPE_ST_P_PLUS 67 ST DTLTYPE_ST_P_MINUS 68 ST DTLTYPE_SIST_PERCENT_PLUS 69 SIST DTLTYPE_SIST_PERCENT_MINUS 6A SIST DTLTYPE_ST 6F ST DTLTYPE_MDST 70 MDST DTLTYPE_PRT_CHAR 71 PRINT CHAR...

Page 77: ...e in the collection master are all reset Data transferring flow IDC data in each terminal totalizer is appended to the consolidation file individually Notes Just after IDC starts the total file is cleared to receive new data Just after the receiving is over the data is remained in the consolidation file To clear this data send the Z command or the file clear command to the collection master from t...

Page 78: ...ceipt from electronic journal 2 13 1 Storing electronic journal The electronic journal starts automatically and it ends if the journal memory becomes full When the memory becomes full the terminal alerts end error which you can select to alert or not to alert by programming Refer to the page 38 of the programming manual Notes Even if the electronic journal memory is full registrations are not dist...

Page 79: ...e data send command to the collection master for the collected electronic journal data 4 PC receives the collection data from the master If the Z command has issued at step 3 electronic journal file in the satellite is all reset 5 Repeat step 1 4 for all satellites Data transferring flow Electronic journal data in each terminal is appended to the consolidation file individually Satellite 1 file Sa...

Page 80: ...R 80 Application System ...

Page 81: ...re configuration R 93 3 3 11 Item Data Capture R 94 3 3 12 Euro change over R 95 3 3 13 Clerk window R 96 3 3 14 Customer R 97 3 3 15 Customer busy reset R 98 3 3 16 Sound R 98 3 3 17 Clerk number R 99 3 3 18 Operation monitor R 99 3 4 System command execution R 100 3 4 1 X Z reporting R 100 3 4 2 X Z collection consolidation R 101 3 4 3 Remote power control R 102 3 5 Data communication system R 1...

Page 82: ...Start End Hardware reset All RAM reset Inline ID definition File creation 1 File creation 2 Initialization result to E journal Revise terminal connection table Input password see above Initialization operation Input date time ID etc Receiving program from other terminal or CF card Start Hardware reset Initialize work area buffers flags Initialization result to E journal End Menu selection FC Init2...

Page 83: ...le 8 COM 4 Use remote printer 1 0 COM3 Use remote printer 2 0 Use remote display 3 COM 2 Use slip printer SP 1300 0 Use hand held scanner HHS 15 1 COM 1 Use XMODEM 0 D5 D4 D3 D2 D1 Significant number Significant number Significant number Significant number Significant number 3 2 IPL Initial Program Loading IPL should be made before initializing when the application software has been modified 3 2 1...

Page 84: ...e IPL operation Connectsourceterminal cashregisterterminal PC andtargetterminalsorinserttheIPLCF card to the terminal CF card IPL source IPL target IPL Data CF card slot is located on the backside of the terminal PC IPL source COM 1 port IPL target IPL Data ...

Page 85: ...he START key to proceed in case of downloading via inline automatic ID definition is made by this timing So press the YES key terminal by terminal 4 After finishing IPL machine initialization is necessary xxxxxxx xxxxxxx IPL CF CARD xxxxxxx xxxxxxx xxxxxxx xxxxxxx IPL COM1 PORT xxxxxxx xxxxxxx xxxxxxx xxxxxxx xxxxxxx xxxxxxx xxxxxxx START CANCEL using COM PORT xxxxxxx xxxxxxx 115200 bps xxxxxxx 57...

Page 86: ...nnection status of terminals and printers 1 Sign on a clerk if necessary 2 Press Manager to assign manager mode 3 Select 1 System Connection Check and press the YES key 4 After checking the system connection press the ESC key to return the previous menu Note If there is unrecognized terminal there it shows as below example 04 MGR C01 10 10 01 12 34 000000 Manager Mode 1 System Connection Check 2 R...

Page 87: ...erk if necessary 2 Press Manager to assign manager mode 3 Select 3 Remote Off and press the YES key 4 Select all terminals or individual terminal select YES to execute this command MGR C01 10 10 01 12 34 000000 Manager Mode 1 System Connection Check 2 Remote On 3 Remote Off 4 Busy Reset 5 Stock Maintenance 6 Drawer for Clerk 7 CHK CLK Interrupt 8 Order ID Change 0 00 MGR C01 10 10 01 12 34 000000 ...

Page 88: ... necessary 2 Press Manager to assign manager mode 3 Select 4 Busy Reset and press the YES key 4 Enter the appropriate check number and then select YES to execute this command MGR C01 10 10 01 12 34 000000 Manager Mode 1 System Connection Check 2 Remote On 3 Remote Off 4 Busy Reset 5 Stock Maintenance 6 Drawer for Clerk 7 CHK CLK Interrupt 8 Order ID Change 0 00 Busy Reset Check No 12 OK YES 0 00 B...

Page 89: ...xt PLU appears on the screen 6 Press the ESC key to terminate this sequence 7 Press the ESC key to issue receipt MGR C01 10 10 01 12 34 000000 Manager Mode 1 System Connection Check 2 Remote On 3 Remote Off 4 Busy Reset 5 Stock Maintenance 6 Drawer for Clerk 7 CHK CLK Interrupt 8 Order ID Change 0 00 No Descriptor Stock 1 PLU0001 0 000 0 000 0 00 No Descriptor Stock 1 PLU0001 100 000 100 000 2 PLU...

Page 90: ...sign manager mode 3 Select 7 CHK CLK Interrupt and press the YES key The display shows Clerk name Check No list 4 Select the check No field of the appropriate clerk enter the check number within 6 digits and press the YES key 5 Press the ESC key to return the previous menu MGR C01 10 10 01 12 34 000000 Manager Mode 1 System Connection Check 2 Remote On 3 Remote Off 4 Busy Reset 5 Stock Maintenance...

Page 91: ...Select YES of the last line to execute this command Note D3 D2 D1 In case of D3 1 D2 D1 defines the terminal physical ID that connect to printer 1 In case of D3 2 D2 D1 defines the terminal physical ID that connect to printer 2 MGR C01 10 10 01 12 34 000000 Manager Mode 1 System Connection Check 2 Remote On 3 Remote Off 4 Busy Reset 5 Stock Maintenance 6 Drawer for Clerk 7 CHK CLK Interrupt 8 Orde...

Page 92: ...int error log If you do not want to print error log press the ESC key MGR C01 10 10 01 12 34 000000 Manager Mode 3 Remote off 4 Busy Reset 5 Stock Maintenance 6 Drawer for Clerk 7 CHK CLK Interrupt 8 Order ID Change 9 Error Log Print 10 System Re configuration 0 00 ID Date Time OPE ERR JOB 01 MC 01 0603 1535 1 51 38 03 MC 03 0603 1535 22 235 22 0 00 Error Log Print Do you want to printout YES 0 00...

Page 93: ...ams 4 Activate System re configuration command at the terminal on which the Cut off icon is lit 1 Sign on a clerk if necessary 2 Press Manager to assign manager mode 3 Select 10 System Re configuration and press the YES key 4 Choose the option YES Perform system re configuration NO Abort this procedure and press the YES key System Re configuration System Re configuration NO OK YES 0 00 ß MGR C01 1...

Page 94: ...sign manager mode 3 Select 11 Item Data Capture and press the YES key 4 Choosetheoption YES captureitemdata NO notcapture item data and press the ESC key Item Data Capture Item Data Capture YES 0 00 MGR C01 10 10 01 12 34 000000 Manager Mode 9 Error Log Print 10 System Re configuration 11 Item Data Capture 12 EURO Change over 13 Clerk Window 14 Customer 15 Customer Busy Reset 16 Recording 0 00 ...

Page 95: ...If you want to proceed this step press the YES key To abort this step press the NO or ESC key 5 If you want to proceed this step enter 8888888888 and press the YES key It takes a few minutes To abort this step press the NO or ESC key Perform the same operation of all the terminals of the system MGR C01 10 10 01 12 34 000000 Manager Mode 9 Error Log Print 10 System Re configuration 11 Item Data Cap...

Page 96: ...lect the appropriate key in the clerk window 7 Press the YES key to set this program MGR C01 10 10 01 12 34 000000 Manager Mode 9 Error Log Print 10 System Re configuration 11 Item Data Capture 12 EURO Change over 13 Clerk Window 14 Customer 15 Customer Busy Reset 16 Recording 0 00 Clerk Window Clerk Window Disable 0 00 Key Assign OK YES 0 00 Clerk Window Clerk Window 1 Disable 2 Clerk window 1 3 ...

Page 97: ...s per formed Customer name up to 24 characters Customer title select from sub menu Customer address 1 up to 24 characters Customer address 2 up to 24 characters Customer address 3 up to 24 characters Customer address 4 up to 24 characters Customer phone No up to 12 digits Customer group select from sub menu 5 Press the ESC to set and continue to program new cus tomer MGR C01 10 10 01 12 34 000000 ...

Page 98: ...1 Item Data Capture 12 EURO Change over 13 Clerk Window 14 Customer 15 Customer Busy Reset 16 Recording 0 00 Busy Reset CUST No 123456 Dr Big Scientist BALANCE 45 90 DISCOUNT 3 23 RECEIPT 3 3 16 Sound This command is used to play the programmed sound file or to record to the sound file 1 Sign on a clerk if necessary 2 Press Manager to assign manager mode 3 Select 16 Recording and press the YES key...

Page 99: ...clerk s operation by monitoring display and receipt in case of connecting printer 1 Sign on a clerk if necessary 2 Press Manager to assign manager mode 3 Enter 99990000nn nn terminal ID No to monitor and press the ST to start operation monitor Note Do not designate the monitored or monitoring terminal The display shows the screen of the monitored terminal The receipt shows the printout of the moni...

Page 100: ...action D6 1 Inactive Zero sales 0 No extraction D5 1 By Range 3 Clerk individual 0 Execution in X mode D4 1 Execution in Z mode 2 Edit employee data 0 Issuing daily area 1 Issuing periodic 1 area D3 2 Issuing periodic 2 area 3 Issuing daily consolidation area 4 Issuing periodic 1 consolidation area 5 Issuing periodic 2 consolidation area 71 Flash 00 09 Batch report 1 10 11 Fixed totalizer 12 Trans...

Page 101: ... D7 2 Editing by department 3 Editing by subdepartment 4 Editing by order character 0 No extraction D6 1 Inactive Zero sales 0 No extraction D5 1 By Range D4 0 Execution in X mode 1 Execution in Z mode 0 Issuing daily area D3 1 Issuing periodic 1 area 2 Issuing periodic 2 area 00 09 Batch report 1 10 11 Fixed totalizer 12 Transaction 14 PLU 64 PLU stock 13 Subdepartment 15 Department 16 Group D2 D...

Page 102: ...emote power control Remote power control execution Manager mode D4 D3 D2 D1 2 Meaning of the command data Digit Value Meaning D4 D3 00 All terminal 01 32 Terminal ID of individual terminal D2 D1 10 Remote power on 11 Remote power off ...

Page 103: ...ard For MODEM or PC direct connection RS 232C COM2 Standard For Hand held scanner or Slip printer RS 232C COM3 Standard For Remote customer display RS 232C COM4 Standard For Remote printer or Slip printer RS 232C COM5 Standard For Remote printer RS 232C COM6 Standard For Remote printer DC IN PC MODEM SCANNER DISPLAY DRW1 DRW2 COM1 COM4 COM2 COM5 COM3 COM6 SPK MIC LAN1 VOL COM1 COM4 COM2 COM5 COM3 ...

Page 104: ...hub to hub Maximum 4 hubs in one cluster Maximum cable length between terminal and terminal via hubs is 500m Using 100Base TX Cable length 100m hub to terminal hub to hub Maximum 2 hubs in one cluster Maximum cable length between terminal and terminal via hubs is 300m Max 100m Max 500m Max 100m Max 100m Max 100m Max 100m Max 100m Max 100m Max 100m Max 300m Max 100m Max 100m Configuration with Hub ...

Page 105: ...e cable diagram between the terminal and PC Wireless inline Wireless inline system requires wireless LAN card installed in the QT 6000 terminal and access point Via access point and hub wireless inline terminal can communicate with the wired inline terminal Access Point Access Point Hub Terminal COM 1 MODEM Pin Signal Signal Pin No name name No 3 SD TDX SD 2 2 RD RXD RD 3 7 RS RTS RS 4 8 CS CTS CS...

Page 106: ... terminal 2 X Z data consolidation for each terminal 3 X Z data collection consolidation for each terminal 4 Program data copy and upload between terminals auto program function Functions1 2 and3 canonlybeperformedfromaterminalthatisprogrammedasmaster in which consolidation files are allocated 3 5 3 2 Online functions The QT 6000 can be controlled from the personal computer by connecting it to RS ...

Page 107: ...es accumulate registered data Periodic total 1 files These files accumulate registered data at the point of sale and can be reset independently from the daily total files Therefore the total data within specific period can be accessed by using these files Periodic total 2 files These files have same functions as the periodic total 1 files but can reset independently for getting the different perio...

Page 108: ...03 603 PLU 004 104 204 304 404 504 604 Department 005 105 205 305 405 505 605 Group 006 106 206 306 406 506 606 Clerk detail 011 111 211 311 411 511 611 Hourly sales 009 109 209 309 409 509 609 Monthly sales 010 110 210 310 410 510 610 Void table 012 112 212 312 412 512 612 Table analysis 018 118 218 318 418 518 618 Grand total 020 120 220 320 420 520 620 Hourly item 021 121 221 321 421 521 621 Ho...

Page 109: ...e item 1 to 3 are executed for the other terminals Data will be sent without the clerk noticing even when the satellite in the process of registering 3 6 1 2 Z collection processing Z collection processing is performed as the figure shown below 1 When a Z collection command is started up from the master terminal the master first locks one objected terminal Z lock 2 The objected terminal sends its ...

Page 110: ... compulsory is set enter in drawer amount and press or NS before issuing report X Z C01 10 10 01 12 34 000000 Inline X Z 1 Collection 2 Consolidation 3 Collection Consolidation C 01 0 00 Collection Collection 1 Daily X 2 Periodic 1 X 3 Periodic 2 X 4 Daily Z 5 Periodic 1 Z 6 Periodic 2 Z C 01 0 00 Collection Daily X 1 Batch 2 Cashier Clerk 3 Customer Account 4 Others C01 0 00 Collection Target ECR...

Page 111: ...onsolidation work file 3 The data in the consolidation work file is added to the consolidation file 4 The same process described in item 1 to 3 is executed for other terminals 5 After the above collection processing is completed for all objected terminals the data accumulated in the consolidation work file are reported on the master s R J printer 3 6 2 2 Z consolidation processing Z consolidation ...

Page 112: ...ou finish to designate terminal s 6 Press the ESC key twice to terminate this process NOTE If money declaration compulsory is set enter in drawer amount and press or NS before issuing report X Z C01 10 10 01 12 34 000000 Inline X Z 1 Collection 2 Consolidation 3 Collection Consolidation C01 0 00 Consolidation Consolidation 1 Daily X 2 Periodic 1 X 3 Periodic 2 X 4 Daily Z 5 Periodic 1 Z 6 Periodic...

Page 113: ... satellites are locked from registrations After consolidating data from all objected terminals the master prints the details on the receipt journal printer 3 6 2 1 X collection consolidation processing X collection consolidation processing is performed as the figure shown below 1 An X collection consolidation command is started up from the master terminal 2 Data of the objected terminal file are s...

Page 114: ...n work file are reported on the master s R J printer 4 The data in the consolidation work file is added to the consolidation file 5 After the master terminal s processing completes the same processes described in item 1 to 4 are executed for all other terminals 6 The data accumulated in the consolidation file are reported on the master s R J printer 7 Aftertheabovecollectionprocessingcompletesfora...

Page 115: ...ory is set enter in drawer amount and press or NS before issuing report X Z C01 10 10 01 12 34 000000 Inline X Z 1 Collection 2 Consolidation 3 Collection Consolidation C 01 0 00 Collection Consolidation Collection Consolidation 1 Daily X 2 Periodic 1 X 3 Periodic 2 X 4 Daily Z 5 Periodic 1 Z 6 Periodic 2 Z C 01 0 00 Collection Consolidation Daily X 1 Batch 2 Cashier Clerk 3 Customer Acoount 4 Oth...

Page 116: ... or insert a CF card during sending receiving data from to it 3 7 1 Auto programming functions The QT 6000 terminal is capable of saving and loading terminal program files The terminal program file has the following transfer functions 1 Copy all terminal files send receive send activation by source terminal receive activation by target terminal This function copies all terminal files except termin...

Page 117: ...g PLU link Table Analysis GT Character General Feature Special Character Report Header Tax Table Pulldown Group Set Menu Table Clerk key ID Batch X Z Clerk Detail Receipt SLIP Msg Endorse Message ARG GP1 ARG GP2 ARG GP3 ARG GP4 ARG GP5 Text Recall Check Print Graphic Logo EXT PRN PLU 2nd Shift PLU Scheduler Order Char Link Keyboard Character Keyboard System Connection I O Parameter Printer Connect...

Page 118: ... PLU Scheduler Order Char Link Keyboard Character Keyboard System Connection I O Parameter Printer Connection Hourly Item Link Mix match Time Zone Employee Job Code Schedule IDC Link Euro Sub Currency Preset Auto Pgm control LCD color Customer Customer GP Customer Title Menu Title CF X Z Conv CHK Window Clerk Window Sound 1 Sound 2 Sound 10 Color Definition Color Theme BMP Picture Wireless LAN fut...

Page 119: ...ry 2 Press the CF CARD key to assign CF card 3 Insert the CF card to the slot securely Select 4 CF Card Format and press the YES key 4 Press the YES key to continue formatting NO means abortion X Z C01 10 10 01 12 34 000000 CF Card 1 Data Backup 2 Data Restore 3 Backup File List 4 CF Card Format 0 00 Backup File List FILE001P 001 10 10 01 10 00 FILE002P 002 10 10 01 10 01 FILE003P 003 10 10 01 10 ...

Page 120: ...R 120 Manager Operation ...

Page 121: ...ist function R 126 4 6 Using the set menu function and pulldown group function R 127 4 7 Post entry R 130 4 8 Separate check R 131 4 9 Open check R 132 4 9 Dutch account R 132 4 10 Media change R 133 4 11 Eat in Takeout R 134 4 12 Scanning PLU R 134 4 13 Shift PLU R 135 4 14 Printing barcode on receipts UP 350 and UP 360 R 135 4 15 Round repeat function R 136 4 16 Mix match coupon R 137 4 17 Custo...

Page 122: ...he clerk key on the keyboard or in the clerk pop up window It is the same procedure that even clerks are assigned as clerk cashier or manager 1 Clerk sign on operation Clerk key has the clerk number setting 1 Just press the appropriate CLERK key in the keyboard or in the clerk pop up window 2 Clerk sign on operation Clerk key has no clerk number setting In case of the store has many clerks to cont...

Page 123: ...ed using departments subdepartments PLUs partial tenders or the PRICE LOAN or PICKUP key You can only use the VOID key to cancel a registration if you have not yet started registration of the next item 1 Wrong registration is made 2 Press the VOID key to cancel the data and reregister the transaction REG 10 10 01 12 34 000001 CLK Please sign on REG C01 10 10 01 12 34 000001 0 00 Please sign on REG...

Page 124: ... during the transaction Press the CANCEL key to cancel all data registered except partial tendering during thetransaction Thisoperationletsyouclearregistereddataandrestartfromthebeginning The cancel operation must be performed before the transaction is finalized 1 Wrong registration is made REG C01 10 10 01 12 34 000001 1 PLU0001 1 00 1 PLU0002 2 00 3 PLU0003 9 00 1 PLU0004 4 00 PLU0004 4 00 6 16 ...

Page 125: ... YES key to cancel the transaction REG C01 10 10 01 12 34 000001 1 PLU0001 1 00 1 PLU0002 2 00 3 PLU0003 9 00 1 Cancel OK PLU0004 4 00 6 16 00 REG C01 10 10 01 12 34 000001 1 PLU0001 1 00 1 PLU0002 2 00 3 PLU0003 9 00 1 PLU0004 4 00 CANCEL CANCEL 0 00 Please sign on ...

Page 126: ...ual Normal registration by using the LIST and LIST key List pop up window 1 Press the LIST key or enter the list No and press the LIST key ThentheListpop upwindowisopenedonthe keyboard 2 Select the appropriate item Direct selection by using the LIST key 1 Press the appropriate record number and press the LIST key brings direct selection of the item REG C01 10 10 01 12 34 000001 1 PLU0001 10 00 PLU...

Page 127: ...le page 29 of the programming manual 2 Programming PLU Set menu table linking page 78 of the programming manual 3 Programming item prices page 118 of the programming manual 1 Registering a PLU linked to a set menu 4 6 2 Using the Pulldown group function PLU Parent registration Child PLU 1 Child PLU 2 Child PLU 3 Select one of these REG C01 10 10 01 12 34 000001 1 PLU0001 10 00 PLU0001 10 00 1 10 0...

Page 128: ...p appears on the screen You can also select items directly by using the pulldown key 4 6 4 Using the substitution key Normally you can select item s in a pulldown group If the customer requires to take an item from another set menu pulldown group the SUBSTITUTION key should be used 1 A PLU linked to a pulldown group is registered but no items in the list can be selected REG C01 10 10 01 12 34 0000...

Page 129: ... Note Program Fast food in the Set Menu Condiment program page 39 of the programming manual 1 An multiplication of a PLU is made 2 Enter appropriate quantity and press the X key REG C01 10 10 01 12 34 000001 1 PLU0020 10 00 1 PLU0021 20 00 1 PLU0050 50 00 PLU0050 50 00 3 80 00 REG C01 10 10 01 12 34 000001 3 PLU0001 30 00 PLU0001 30 00 3 30 00 REG C01 10 10 01 12 34 000001 3 PLU0001 30 00 X 2 3 30...

Page 130: ... 1 Openthecheckanddesignate POSTENTRY by Pressing the POST ENTRY key recalls the pulldown menu screen to select items REG C01 10 10 01 12 34 000001 3 PLU0001 30 00 2 PLU0010 2 00 PLU0010 2 00 5 32 00 REG C01 10 10 01 12 34 000001 1 Lunch menu 12 00 Soup Chicken with pepper Sirloin Rare French Pea 0 00 1 12 00 REG C01 10 10 01 12 34 000001 1 Lunch menu 12 00 Soup Chicken with pepper Sirloin Rare Fr...

Page 131: ...ened 3 Select the transferring items in the original check column it is transferred to the other check column 4 After selecting items press the OK key in the separate check window to terminate The selected items are trans ferred to other check REG C01 10 10 01 12 34 000001 CHECK No 222222 NEW OLD 222222 REG C01 10 10 01 12 34 000001 CHECK No 222222 1 PLU0002 2 00 1 PLU0004 4 00 ST 6 00 0 00 2 ST 6...

Page 132: ...e shared total receipts per customer Receipt for the last customer Receipt for other customers Note The fractions are included in the last customer REG C01 10 10 01 12 34 000001 0 01 REG C01 15 12 03 12 34 000001 X 0000025 OPEN CHK MC 01 REG C01 15 12 03 12 50 001190 CHECK No 1328 100 35 MC 01 REG C01 15 12 03 12 55 001195 CHECK No 1330 MC 01 REG C01 15 12 03 12 58 001205 CHECK No 1363 0 01 REG C0...

Page 133: ...ssthemedia key to be changed 3 Enter the amount to change and press the media to change until the change amount equals to the changed amount REG C01 10 10 01 12 34 000001 MEDIA CHG REG C01 10 10 01 12 34 000001 MEDIA CHG CASH 10 00 CASH 10 00 10 00 REG C01 10 10 01 12 34 000001 MEDIA CHG CASH 10 00 CHECK 2 00 CHECK 2 00 8 00 REG C01 10 10 01 12 34 000001 MEDIA CHG CASH 10 00 CHECK 2 00 CREDIT 8 00...

Page 134: ...Example of receipt image 1 Hamburger 2 00 1 French fries 1 50 1 Coffee 1 00 TAKE OUT 4 12 Scanning PLU This function is used for registering PLU items by scanner or OBR code OBR Before using this function you should allocate the scanning PLU link file file no 16 program the start record number of scanning PLU link page 33 of the programming manual and OBR code to the scanning PLU link file Applica...

Page 135: ...ion example OPERATION 1 Register PLU0001 PLU0001 level 2 200 PLU0001 SHIFT PLU level2 200 PLU0001 level 3 PLU0001 SHIFT PLU level3 PLU0001 CASH 4 14 Printing barcode on receipts UP 350 and UP 360 This function is used for registering old check by scanning the barcode on the new balance receipt or issuing guest receipt by scanning the barcode on the finalizing receipt Example of receipt image 1 Ham...

Page 136: ...he check number of this receipt and press the NEW OLD key 3 Press ROUND REPEAT to recall the last receipt REG C01 10 10 01 12 34 000001 CHECK No 1111 1 PLU0001 1 00 1 PLU0002 2 00 1 PLU0003 3 00 NEW OLD 1111 3 ST 6 00 REG C01 10 10 01 12 34 000001 CHECK No 1111 1 PLU0001 1 00 1 PLU0002 2 00 1 PLU0003 3 00 SRVC TL 6 00 SRVC TL 6 00 REG C01 10 10 01 12 34 000001 CHECK No 1111 1 PLU0001 1 00 1 PLU000...

Page 137: ...elected Target item PLU Flat PLU Department Subdepartment bundle quantity Combi item 1 5 PLU Flat PLU Department Subdepartment bundle quantity 2 Allocate coupon number key 110 Mix and match type 1 Item registration PLU0001 PLU0002 PLU0003 Coupon type 1 Item registration PLU0011 PLU0012 PLU0013 1234 CPN REG C01 10 10 01 12 34 000001 1 PLU0011 1 00 1 PLU0012 2 00 1 PLU0013 3 00 DISCOUNT02 0 12 PLU00...

Page 138: ...TRANSFER key to finalize the transac tion Payment by DEPOSIT key 1 Enter customer No and press the CUST customer ID No key 2 Perform item registration 3 Enter tendered amount and press the DEPOSIT key 4 Press the TABLE TRANSFER key to finalize the transac tion Payment by PAYMENT key 1 Press the PAYMENT key 2 Enter customer No and press the CUST customer ID No key 3 Perform a finalize operation Not...

Page 139: ...o if necessary 1 By pressing ORDER CHARACTER CHANGE key the order character window appears in the screen You can change the appropriate order character in the win dow If the linking order character record No is set the order character is changed to the linking character automatically 4 20 Item search Before using this function the following programs are necessary 1 Allocating item search key 246 2...

Page 140: ...R 140 Registration ...

Page 141: ...R 141 QT 6000 Reference Manual 5 Refund mode operation R 140 5 1 Selecting REF or REG mode R 140 ...

Page 142: ... RF or REG key to turn that mode Refund registration or register minus REG registration starts with this operation Note Key operations are similar to that in the register mode To avoid miss registration in the REF or REG mode return the mode to the former one immediately REG C01 10 10 01 12 34 000001 REG Mode C01 RF C01 10 10 01 12 34 000001 REFUND Mode C01 R C01 10 10 01 12 34 000001 REG Mode C01...

Page 143: ...R 143 QT 6000 Reference Manual 6 Read and reset operations R 144 6 1 The procedures of reading or resetting R 144 6 2 Report sample R 146 ...

Page 144: ...tored to the totalizers and counters 6 1 The procedures of reading or resetting 1 Sign on a clerk if necessary 2 Press X Z MODE to assign X Z report 3 Select the appropriate menu you want by following the guidances The hierarchy of the X Z menus are described below Refer to page 100 of this manual for X Z command X Z C01 15 12 96 12 34 000000 X Z Report 1 Daily X 2 Periodic 1 X 3 Periodic 2 X 4 Da...

Page 145: ...sh Daily X only Fixed totalizer Free Function PLU PLU stock Daily X Z only Sub Department Department Group Hourly sales Monthly sales Table analysis Void Hourly product Discount Coupon IDC IDC n clear Z only n 1 3 Periodic 1 X Batch Same as Daily X Cashier Clerk Same as Daily X Customer Account Same as Daily X Others Same as Daily X Periodic 2 X Same as Periodic 1 X Daily Z Same as Daily X Periodi...

Page 146: ...3 1 GROSS 21 45 00 NET No 5 40 00 CAID 35 00 Cashier report CHID 3 00 CKID 0 00 CRID 0 00 CASH No 10 35 00 C10 1 GROSS 10 18 00 NET No 8 18 00 CAID 15 00 Clerk report CHID 3 00 CKID 0 00 CRID 0 00 CASH No 5 15 00 Individual key Z 0001095 Mode Report code CASH No 11 38 00 Function key descriptor Counter Totalizer CHECK No 0 0 00 CREDIT No 1 12 00 ADD CHK No 0 TL 12 50 00 TL descriptor Counter Total...

Page 147: ... Grand total 1 GT2 1569567830 40 Grand total 2 descriptor Grand total 2 GT3 1325670420 24 Grand total 3 descriptor Grand total 3 000001 001279 Consecutive No range Free function Z 0001012 FREE FUNCTION 123 Mode Report code Report title Z No Z only CASH No 11 38 00 Transaction key descriptor Counter Amount RC No 2 8 00 PD No 1 1 00 PLU Z 0001014 PLU 123 Mode Report code Report title Z No Z only PLU...

Page 148: ...UNT 1 00 Discount total can be skipped 0001 68 25 PLU No can be skipped Sales ratio can be skipped PLU0002 25 32 00 DISCOUNT 5 00 0002 3 2 TL 75 714 55 Total by group dept subdept Counter Amount DISCOUNT 6 00 71 45 GROUP02 02 00 PLU0005 1 2 00 Non Group dept subdept link items DISCOUNT 0 00 0005 0 2 TL 1 2 00 DISCOUNT 0 00 0 2 PLU by order character X 4000014 PLU Mode Report code Report title Z No...

Page 149: ...descriptor Counter Amount DISCOUNT 0 00 0001 PLU No can be skipped PLU0002 0 0 00 GROUP02 02 TL 0 0 00 DISCOUNT 0 00 TL 0 0 00 DISCOUNT 0 00 PLU stock PLU less stock X 0000064 PLU STOCK Mode Report code Report title Z No Z only PLU0001 10 123 45 PLU descriptor Minimum stock level Current stock 0001 PLU No can be skipped PLU0002 25 20 short stock 0002 PLU stock by range X 0010064 PLU STOCK Mode Rep...

Page 150: ...45 TL 151 156 55 DISCOUNT 3 00 100 00 Subdepartment by range X 0010013 SUB DEPT Mode Report code Report title Z No Z only 0001 0002 Range SUBDEPT01 24 82 55 Subdepartment descriptor Counter Amount DISCOUNT 1 00 Discount total can be skipped 70 82 Sales ratio can be skipped SUBDEPT02 25 32 00 DISCOUNT 2 00 27 45 TL 49 114 55 DISCOUNT 3 00 98 27 Subdepartment by group dept X 100013 SUB DEPT Mode Rep...

Page 151: ...BDEPT04 0 0 00 DISCOUNT 0 00 TL 0 0 00 TL 0 0 00 No group link items total DISCOUNT 0 00 TL 0 0 00 DISCOUNT 0 00 Department all X 0000015 DEPT Mode Report code Report title Z No Z only DEPT01 24 82 55 Department descriptor Counter Amount DISCOUNT 1 00 Discount total can be skipped 70 82 Sales ratio can be skipped DEPT02 25 32 00 DISCOUNT 2 00 27 45 TL 151 156 55 DISCOUNT 3 00 100 00 Department by ...

Page 152: ...code Report title DEPT01 0 0 00 Department descriptor Counter Amount DISCOUNT 0 00 Discount total can be skipped DEPT02 0 0 00 DISCOUNT 0 00 TL 0 0 00 DISCOUNT 0 00 Department zero sales by group X 1100015 DEPT Mode Report code Report title GROUP01 01 Group title DEPT01 0 0 00 Department descriptor Counter Amount DISCOUNT 0 00 Discount total can be skipped DEPT02 0 0 00 DISCOUNT 0 00 TL 0 0 00 TL ...

Page 153: ... 57 Gross counter Gross amount NET No 12 680 50 Net counter Net amount 8 GROSS 78 1 034 59 NET No 37 1 034 57 TL GROSS 130 1 715 16 13 19 Average gross sales NET 49 1 715 07 35 00 Average net sales Table analysis Z 0001028 TABLE ANALYSIS 123 Mode Report code Report title Z No Z only TBL0001 CT 12 680 57 Table No Customer count Net amount 50 12 Sales ratio can be skipped TBL0002 CT 5 279 56 10 04 T...

Page 154: ...D 1 00 Finalized status CHECK NO 003333 NEW OPEN 0 00 Newly opened status TL No 4 360 80 Electronic journal E journal Z 0001058 E JOURNAL Mode Report code Report title MC 03 REG C01 07 11 2005 16 34 001029 1 PLU0055 100 00 0 12 0 12 Registrations TL 99 88 CASH 99 88 MC 03 P1 C01 07 11 2005 16 35 001030 Some program are made in Program 1 mode MC 03 X Z C01 07 11 2005 16 37 001031 X 0100015 DEPT Rep...

Page 155: ...yet then is printed on WORK 4 JOB summary is printed in order to clock in the shift If there is the same JOB code then it will add to the JOB that was found before 5 If employee is not clocked out the shift then is printed No JOB is printed if employee is not clocked in the shift Employee report weekly bi weekly X 000129 EMPLOYEE 123456 HARRISON 123456789 Monday 12 21 03 Day of the week Date 2 IN ...

Page 156: ...34 5 1 234 50 20 9 89 6 172 62 TL 62 395 07 Total Amount of all Time frame Hourly labor report Z 0001024 HOURLY LABOR 1234 Mode Report code Report title Z counter Z only 09 00 09 30 No 2 2 469 06 Time frame NET counter NET Amount 82 62 NET ratio COST 00 05 0 08 Work time Pay 0 Pay ratio NET SALES HOUR 29 628 72 Proceeds per work time COST TRANSACTION 0 04 Wages per transaction 09 30 10 00 No 10 16...

Page 157: ...d total BUSY Busy Occupied flag CUST No 000022 BALANCE 110 23 DISCOUNT 1 23 FINALIZED GT 616 36 DISCOUNT GT 41 23 TL No 2 No of customer BALANCE 120 46 Customer balance total DISCOUNT 2 46 Customer discount total Customer open check total only X 0040047 CUSTOMER Mode Report code Report title Z counter Z only TL No 2 No of customer BALANCE 120 46 Customer balance total DISCOUNT 2 46 Customer discou...

Page 158: ...58 Read and Reset Mix and match X 0000061 MIX MATCH Mode Report code Report title Z counter Z only Bundle A Discount descriptor No 2 10 46 Customer balance total 01234 Coupon No Bundle B No 23 120 46 0111 ...

Page 159: ...R 159 QT 6000 Reference Manual A 1 Function key list R 160 ...

Page 160: ...t PLU nnnn F S FSST FSTD HOUSE BON SEARCH X KETTEN LIST LIST LOAN LOCATION NOP MEDIA CHG MENU MDST X NB NEW CHK NEW OLD NRMRCT NS NS CT OBR OLD CHK OPEN OPEN2 OPEN CHK OPE Function Code Initial character Operator read reset 073 Order character change 252 Paid out 021 Payment 149 Pick up 022 Plus 029 PLU 048 Post entry 115 Premium 030 Price 049 Price inquiry 008 Quantity for 083 Recall 131 Receipt ...

Page 161: ... file R 169 A 2 6 1 Group daily R 169 A 2 6 2 Group periodic consolidation R 169 A 2 7 Clerk file R 170 A 2 7 1 Clerk programming R 170 A 2 7 2 Clerk detail daily periodic consolidation R 171 A 2 7 3 Clerk detail link R 171 A 2 7 4 Clerk i Button key ID R 171 A 2 8 Hourly sales file R 172 A 2 8 1 Hourly sales daily periodic consolidation R 172 A 2 9 Monthly sales file R 172 A 2 9 1 Monthly sales d...

Page 162: ...acter file R 183 A 2 19 1 Special character R 183 A 2 21 Tax table file R 183 A 2 19 1 Tax table R 183 A 2 20 Report header file R 183 A 2 20 1 Report header R 183 A 2 22 Pulldown group file R 184 A 2 22 1 Pulldown group R 184 A 2 23 Set menu table file R 184 A 2 23 1 Set menu table R 184 A 2 24 Batch X Z file R 185 A 2 24 1 Batch X Z R 185 A 2 25 Receipt Slip message file R 185 A 2 25 1 Receipt S...

Page 163: ... R 188 A 2 36 1 Clerk pop up window definition file R 188 A 2 37 Sound file R 188 A 2 37 1 Sound 1 10 file R 188 A 2 38 System files R 189 A 2 38 1 Key table R 189 A 2 38 2 Touch screen key table R 189 A 2 38 3 System connection table R 189 A 2 38 4 I O parameter table R 190 A 2 38 5 Printer connection table R 190 A 2 38 6 System error log R 190 A 2 38 7 Auto program control R 190 A 2 38 8 LCD col...

Page 164: ...n drawer 016 Credit declared amount 017 Declared short credit amount 018 Declared over credit amount 019 Food stamp in drawer 020 Food stamp cash change 021 EBT in drawer 022 EBT cash change 023 Refund mode total 024 Customer count 025 Average sales per customer 026 Check cashing service fee 027 New balance fee 028 029 Clerk commission 1 total 030 Clerk commission 2 total Rec No Contents 031 Forei...

Page 165: ... 3 1 Subdepartment daily File name Subdepartment daily File No 003 Max allocatable records 99 A 2 3 2 Subdepartment periodic consolidation File name Subdepartment periodic 1 File No 103 Max allocatable records 99 File name Subdepartment periodic 2 File No 203 Max allocatable records 99 File name Subdepartment daily consolidation File No 303 Max allocatable records 99 File name Subdepartment period...

Page 166: ...lidation work File No 604 Max allocatable records 9999 Counter Totalizer 0 5 10 15 Discount totalizer Not used 20 25 House Bon quantity 30 Stock quantity Character 0 24 31 34 Program 2nd 2nd Q ty Not used Not used 37 Link 43 46 40 Unit stock 47 A 2 4 3 PLU 2nd File name PLU 2nd File No 054 Max allocatable records 9999 Character HALO 0 24 31 34 Program 48 Random code Unit stock Minimum stock Set me...

Page 167: ...consolidation work File No 655 Max allocatable records 9999 Unit price shift 2 Unit price shift 3 Unit price shift 4 Unit price shift 5 Unit price shift 6 Unit price shift 7 Unit price shift 8 Counter shift 2 Totalizer shift 2 0 6 9 3 15 18 12 21 26 31 Counter shift 3 Totalizer shift 3 36 91 41 Counter shift 4 Totalizer shift 4 46 51 Counter shift 5 Totalizer shift 5 56 61 Counter shift 6 Totalize...

Page 168: ...PLU 2nd Program field for PLU department subdepartment PLU 2nd Refer to the Elementary program on page 173 of the programming manual Link field for PLU subdepartment department PLU 2nd Refer to the Field 11 066 on page 174 of the programming manual Random code field for PLU Refer to the Field 12 066 on page 174 of the programming manual Set menu link field for PLU Refer to the Field 13 066 on page...

Page 169: ...allocatable records 99 File name Group periodic 2 File No 206 Max allocatable records 99 File name Group daily consolidation File No 306 Max allocatable records 99 File name Group periodic 1 consolidation File No 406 Max allocatable records 99 File name Group periodic 2 consolidation File No 506 Max allocatable records 99 File name Group consolidation work File No 606 Max allocatable records 99 Ch...

Page 170: ... Function control 2 Refer to the Record 05 067 on page 164 of the programming manual Function control 3 Refer to the Record 06 067 on page 165 of the programming manual Function control 4 Refer to the Record 07 067 on page 166 of the programming manual Function control 5 Refer to the Record 08 067 on page 167 of the programming manual Arrangement control Refer to the Record 09 067 on page 168 of t...

Page 171: ...on File No 311 Max allocatable records 9801 File name Clerk detail periodic 1 consolidation File No 411 Max allocatable records 9801 File name Clerk detail periodic 2 consolidation File No 511 Max allocatable records 9801 File name Clerk detail consolidation work File No 611 Max allocatable records 9801 A 2 7 3 Clerk detail link File name Clerk detail link File No 030 Max allocatable records 99 Co...

Page 172: ...e records 96 A 2 9 Monthly sales file A 2 9 1 Monthly sales daily periodic consolidation File name Monthly sales daily File No 010 Max allocatable records 32 fixed File name Monthly sales periodic 1 File No 110 Max allocatable records 32 fixed File name Monthly sales periodic 2 File No 210 Max allocatable records 32 fixed File name Monthly sales daily consolidation File No 310 Max allocatable reco...

Page 173: ... records 1920 File name Hourly Item periodic 1 consolidation File No 421 Max allocatable records 1920 File name Hourly Item periodic 2 consolidation File No 521 Max allocatable records 1920 File name Hourly Item consolidation work File No 621 Max allocatable records 1920 A 2 10 2 Hourly item link Hourly production link File name Hourly item link File No 031 Max allocatable records 480 Amount 0 5 C...

Page 174: ...riodic 1 consolidation File No 451 Max allocatable records 99 File name Mix and match periodic 2 consolidation File No 551 Max allocatable records 99 File name Mix and match consolidation work File No 651 Max allocatable records 99 Character 0 16 19 21 Discount amount or rate Random code Rec No File No Quantity Comb 1 item 40 39 37 Rec No File No Quantity Comb 2 item 45 44 42 Rec No File No Quanti...

Page 175: ...9 File name IDC 2 consolidation work File No 658 Max allocatable records 9999 File structure is same as IDC file 1 A 2 12 3 IDC file 3 File name IDC 3 File No 059 Max allocatable records 9999 File name IDC 3 daily consolidation File No 359 Max allocatable records 9999 File name IDC 3 consolidation work File No 659 Max allocatable records 9999 File structure is same as IDC file 1 Refer to the page ...

Page 176: ... First week Rec 016 018 Correspond to Saturday of Employee Rec 001 First week Rec 019 021 Correspond to Sunday of Employee Rec 001 First week Rec 020 024 Correspond to Monday of Employee Rec 001 Second week Rec 025 027 Correspond to Tuesday of Employee Rec 001 Second week Rec 028 030 Correspond to Wednesday of Employee Rec 001 Second week Rec 031 033 Correspond to Thursday of Employee Rec 001 Seco...

Page 177: ... Employee File No 801 Max allocatable records 99 Refer to page 54 of the programming manual for details A 2 13 5 Job code file File name Job code File No 802 Max allocatable records 50 Refer to page 53 of the programming manual for details 0 3 Employee No 19 Social Security No Job code 1 PGM 24 252627 Job code 2 Job code 3 Job code 4 Clerk No Work 1 Work 2 Work 3 282930 32 34 36 Character End time...

Page 178: ...loyee Rec 001 Rec 003 Correspond to Monday Shift 3 of Employee Rec 001 Rec 004 Correspond to Tuesday Shift 1 of Employee Rec 001 Rec 005 Correspond to Tuesday Shift 2 of Employee Rec 001 Rec 006 Correspond to Tuesday Shift 3 of Employee Rec 001 Rec 021 Correspond to Sunday Shift 3 of Employee Rec 001 Rec 022 Correspond to Monday Shift 1 of Employee Rec 002 Rec 023 Correspond to Monday Shift 2 of E...

Page 179: ...ile No 612 Max allocatable records 99 A 2 15 Table analysis file A 2 15 1 Table analysis daily File name Table analysis daily File No 018 Max allocatable records 99 A 2 15 2 Table analysis periodic consolidation File name Table analysis periodic 1 File No 118 Max allocatable records 99 File name Table analysis periodic 2 File No 218 Max allocatable records 99 File name Table analysis daily consoli...

Page 180: ... name Grand total periodic 2 File No 220 Max allocatable records 3 fixed File name Grand total daily consolidation File No 320 Max allocatable records 3 fixed File name Grand total periodic 1 consolidation File No 420 Max allocatable records 3 fixed File name Grand total periodic 2 consolidation File No 520 Max allocatable records 3 fixed File name Grand total consolidation work File No 620 Max al...

Page 181: ...odic 2 consolidation File No 542 Max allocatable records 99 File name Customer group consolidation work File No 642 Max allocatable records 99 A 2 17 3 Customer title File name Customer title File No 123 Max allocatable records 9 Customer number Customer name Customer address 1 0 55 Customer address 2 79 Customer address 3 103 Customer address 4 127 133 6 31 7 Title link Customer phone No 134 Cust...

Page 182: ...trol 5 138 016 Time frame 139 017 Receipt control 3 Calculation method 140 018 Slip Guest receipt control 141 019 Journal control Electronic journal 142 020 Message print control 142 021 Order control 143 022 Scanning control 143 023 Australian GST control 1 143 024 Australian GST control 2 144 025 Set menu Condiment 144 026 Check tracking 145 027 Clerk interrupt 146 028 Display control 146 029 Me...

Page 183: ...e Special character File No 023 Max allocatable records 78 fixed Character 0 16 Refer to page 112 of the programming manual for details Refer to page 113 of the programming manual for details A 2 21 Tax table file A 2 19 1 Tax table File name Tax table File No 025 Max allocatable records 10 Actual value Rate Max Table amount Rounding 0 74 4 6 7 Singapore rounding 8 Cal type Cyclic pattern Cyclic v...

Page 184: ...o 10 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 Record No 11 Record No 12 Record No 13 Record No 14 Record No 15 Record No 16 Record No 17 Record No 18 File No 11 File No 12 File No 13 File No 15 File No 16 File No 17 File No 18 Record No 19 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 Record No 20 File No 19 File No 20 76 78 80 File No 10 File No 14 Character Record No 1 File...

Page 185: ... X Z code 7 0 1 2 3 4 5 6 7 8 9 10 X Z code 8 A 2 25 Receipt Slip message file A 2 25 1 Receipt Slip message File name Receipt Slip message File No 032 Max allocatable records 96 A 2 26 Check endorsement message file A 2 26 1 Check endorsement message File name Check endorsement message File No 033 Max allocatable records 4 Character 0 40 Character 0 40 Refer to page 110 of the programming manual ...

Page 186: ...ecords 9999 File name Arrangement group 5 File No 438 Max allocatable records 9999 Arrange character 0 24 A 2 28 Character recall file A 2 28 1 Character recall File name Character recall File No 039 Max allocatable records 9999 A 2 29 Check print file A 2 29 1 Check print File name Check print File No 041 Max allocatable records 9 A 2 30 Graphic logo file A 2 30 1 Graphic logo external printer Fi...

Page 187: ...etails A 2 32 Order character file A 2 32 1 Order character File name Order character File No 065 Max allocatable records 99 A 2 33 Euro program file A 2 33 1 Euro program file File name Euro program File No 099 Max allocatable records 3 fixed Program 0 4 Refer to page 155 of the programming manual for details A 2 34 Character conversion for CF file A 2 34 1 Character conversion for CF file File n...

Page 188: ...nd file A 2 37 1 Sound 1 10 file File name Sound 1 File No 701 Max allocatable records 65000 File name Sound 2 File No 702 Max allocatable records 65000 File name Sound 3 File No 703 Max allocatable records 65000 File name Sound 4 File No 704 Max allocatable records 65000 File name Sound 5 File No 705 Max allocatable records 65000 File name Sound 6 File No 706 Max allocatable records 65000 File na...

Page 189: ... Max allocatablerecords 1950 fixed Description Choice Program code Logical ID characters within 12 characters Terminal Oneself 02 Others 01 Check tracking master backup master program value Master 01 Backup master 02 Self master 03 Satellite 00 Check tracking master backup master current value Master 01 Backup master 02 Self master 03 Satellite 00 Always 00000 Check tracking cluster number 0 9 0 m...

Page 190: ...onnection table File name Printer connection table File No 903 Max allocatable records 99 A 2 38 7 Auto program control File name Auto program control File No 905 Max allocatable records 20 File No Program 0 2 3 Refer to page 57 of the programming manual for details A 2 38 8 LCD color control File name LCD color control File No 906 Max allocatable records 99 Refer to page 58 of the programming man...

Page 191: ...06 53 x 106 58 x 130 Quadruple key 118 x 106 113 x 106 130 x 130 C X VOID 7 8 9 4 5 6 1 2 3 0 00 CLK4 CLK3 CLK2 CLK1 ESC SKIP PAGE DOWN FUNC LIST FIN LIST CASH AMT TEND SEP CHK NEW OLD CHK TBL TRANS PAGE UP HOME YES NO MODE CLK COVERS MENU NS SUBTOTAL NB RECEIPT Shift PLU1 Menu1 2nd REG C01 31 10 04 12 34 001234 0 00 Field A Select Check Table number PREV NEXT ESC CHK TBL 1 1 00 2 2 00 PLU010 PLU0...

Page 192: ...atable records 4 Refer to page 63 of the programming manual for details A 2 38 13 Wireless LAN control File name Wireless LAN control File No 899 Max allocatable records 1 Refer to page 63 of the programming manual for details Program 0 6 Program ESS ID character WEP KEY character 0 5 63 37 ...

Page 193: ...R 193 QT 6000 Reference Manual A 3 Counter and Totalizer calculation method R 194 A 3 1 Fixed totalizer file R 194 ...

Page 194: ...ale For REG mode 1 is affected Amount at the finalization exclude tip Department Subdepartment PLU product registration amounts non full hash Last item void amounts for the above Item return amounts for the above Previous item void amounts for the above Cancel amounts for the above Plus key Premium key Error correction amounts Cancel amounts Minus key Discount key Coupon Error correction amounts C...

Page 195: ... Registered amount of Minus key Registered item amount by RF Void key 1 REG REF REG mode When the CLEAR key is pressed Fraction amount by roundings Roundings include IF1 2 Denmark Norway Singapore Finland Australia and New Zealand Void total of ST transfer Subtotal of taxable amount at finalization of sale in case of add on tax Subtotal of taxable amount 1 VAT rate at finalization of sale in case ...

Page 196: ...R 196 Calculation method ...

Page 197: ...R 197 QT 6000 Reference Manual A 5 Error messages R 198 A 5 1 Error messages R 198 A 5 2 Operation prompt R 201 A 5 3 System error code R 202 ...

Page 198: ...exceeds the limit Contents of the drawer exceed the programmed limit Sentinel function H D L H A L L D L error Money declaration compulsory Guest receipt compulsory Validation compulsory Check print compulsory Check endorsement compulsory Registration buffer full Slip compulsory Alarm when no paper is inserted in the Slip Check tracking index full near end Check tracking memory full near end Attem...

Page 199: ... of Bill Copy Press Cancel Key E133 Middle of Media Change Press Cancel Key Printer downed means ECR logical ID and printer number Paper near end end means ECR logical ID and printer number Paper near end end means ECR logical ID and printer number Print buffer full at sender side Down at target ECR which has printer means ECR logical ID and printer number Printer buffer full at target ECR which h...

Page 200: ...IN again Employee attempts to operate CLOCK IN with incorrect JOB code Employees operate CLOCK IN OUT in not allowance time Overtime work There is no available shift left Employee attempts to operate CLOCK OUT whilst he she is in a break time Break hours are exceeded Employee is at work without break Employee who has not done BREAK OUT operation attempts to operate BREAK IN Sign on after you clock...

Page 201: ... sec OK Enter Enter Alphacode Items not found Request to check the X Z report data which cannot be printed out Confirmation to reset displayed report Confirmation of all void operation Please wait ECR now processing In the item consolidation mode Not in the item consolidation mode Mode change REG mode Mode change REF mode Mode change REG mode Signing on a training operator Mode change REG2 mode Th...

Page 202: ...llegal command packet 0048 Illegal command No Not CMD 0049 Illegal command No Not DATA 0050 Sequence error 0051 Turn off DSR signal 0052 Received cancellation 0053 Retry over while waiting command 0054 Retry over while waiting EOT 0055 Retry over while waiting data 0056 Received EOT 0057 Retry over while waiting ACK 0058 Retry over while sending data 0059 Retry over while waiting C 0060 Retry over...

Page 203: ... to get new sled 0164 Error while getting semaphore 0165 Error to operate semaphore 0166 Error during delay 0167 Error during termination 0168 Error when resource return 0170 Error during getting task ID 0171 No code is found while search pick up 0172 Cannot get work buffer 0173 File opened fail to activate task 0174 No file exists 0175 ITRON service error 0176 Cannot create file 0177 Record numbe...

Page 204: ...R 204 Error messages ...

Page 205: ...R 205 QT 6000 Reference Manual Index R 206 ...

Page 206: ... R 160 P 21 clerk pop up window definition R 188 P 17 clerk totalizer R 24 clerk training R 48 clerk transfer R 30 R 160 P 21 clerk window P 76 P 171 clock in R 60 clock in out R 35 R 160 P 21 clock out R 63 collection consolidation system R 19 COM port R 15 R 16 commission rate P 69 P 75 P 81 P 159 communication control P 37 condiment P 39 P 78 connector R 15 connector cover R 10 consecutive numb...

Page 207: ...eter R 190 P 14 P 48 P 150 IDC R 67 R 72 R 156 R 175 P 17 IDC link R 175 P 56 P 154 individual key R 146 INIT2 P 10 initialization P 8 inline R 15 P 48 inner multiplication R 129 insert key P 104 intelligent electronic journal R 78 P 17 item descriptors by range P 108 item search R 37 R 139 R 160 P 21 item type P 81 J job code R 57 R 177 P 16 P 53 P 152 journal control P 38 K Ketten Bon R 36 R 160...

Page 208: ...ce R 33 R 160 P 21 price inquiry R 30 R 160 P 21 print buffer P 17 print control P 34 printer connection table R 190 P 14 P 51 P 150 pulldown group R 127 R 184 P 17 P 28 P 109 P 121 P 128 Q QT 6060D R 16 quadruple key P 22 quantity for R 35 R 160 P 21 R random code P 36 random PLU P 32 recall R 37 R 45 R 160 P 21 receipt R 26 R 32 R 160 P 21 receipt slip message R 185 P 17 receipt message P 110 P ...

Page 209: ...60 P 21 table range P 69 P 75 P 159 table sharing R 37 R 139 R 160 P 21 table transfer R 31 R 45 R 160 P 21 takeout R 36 R 134 R 160 P 21 tax exempt R 34 R 160 P 21 tax status shift R 33 R 160 P 21 tax system P 31 tax table R 183 P 17 P 44 P 150 taxable amount subtotal R 34 R 160 P 21 taxable status P 78 P 81 taxable symbol P 112 TCP IP R 192 P 14 P 63 P 158 terminal file R 23 text print R 30 R 16...

Page 210: ...CASIO COMPUTER CO LTD 6 2 Hon machi 1 chome Shibuya ku Tokyo 151 8543 Japan IR0609 D Printed in Japan QT 6000REF E c ...

Reviews: