Casio 5537 Operation Manual Download Page 10

Getting ready
Enter the Stopwatch Mode.

l

Navigating Between Modes

Measuring Elapsed Time

1.

Use the operations below to measure
elapsed time.

E

A

E

A

Stop

Resume

Stop

Start

Elapsed time is shown in 1/1000-
second units for the first hour of the
measurement session. After the first
hour, elapsed time is shown in 1/10-
second units.

After first hour

Hours, minutes, seconds, 
1/10 seconds

Minutes, seconds, 
1/1000 seconds

First hour

2.

Press (A) to reset the elapsed time to all
zeros.

Measuring Lap Times

1.

Use the operations below to measure
elapsed time.

Each press of (E) causes the elapsed
time of the section (lap time) to be
shown for eight seconds.

E

E

A

Stop

Start

Lap

Elapsed time is shown in 1/1000-
second units for the first hour of the
measurement session. After the first
hour, elapsed time is shown in 1/10-
second units.

After first hour

Hours, minutes, seconds, 
1/10 seconds

Minutes, seconds, 
1/1000 seconds

First hour

2.

Press (A) to reset the elapsed time to all
zeros.

Performing a Stopwatch

Measurement with a Target

Time

You can perform lap time measurement

operations while checking the difference

between the lap time and a target time.

Using a Stopwatch Target Time

Specifying a Target Time
You can specify one of three target times.

FASTEST :
Following start of a stopwatch elapsed time

measurement session, the fastest measured

lap time of the current session is automatically

set as the target time.
TARGET :
You can use EDIFICE Connected to specify a

desired target time.

If you use the watch without connection with a

phone, the target time is automatically set to

15 minutes.
LAST :
Following start of a stopwatch elapsed time

measurement session, the last measured time

of the current session is automatically set as

the target time.

1.

Hold down (A) for at least two seconds.

2.

Press (E) to cycle through the target time

types.

3.

Press (A) to exit the setting screen.

Measuring Elapsed Time
Each time you press (E) to measure a lap time,

the second hand indicates the difference

between the lap time and the target time.

E

E

E

E

A

Lap 1

Start

Stop

Lap 2

Lap 3

[TARGET] Target Time Type :
You can check the difference between the

measured lap time and the target time from the

first lap onwards.
[FASTEST] or [LAST] Target Time Type :
You can check the difference between the

measured lap time and the target time from the

second lap onwards.

Operation Guide 5537

10

Summary of Contents for 5537

Page 1: ...a Race Lap Time Viewing Measured Data Records Lap Times Timer Setting the Countdown Start Time Using the Timer Alarms and Hourly Time Signal Configuring Alarm Settings Setting a Schedule Alarm Enabli...

Page 2: ...charge level is indicated by the mode hand K In the Stopwatch Mode the mode hand indicates speed L In the Timer Mode the mode hand points to TR M In the Alarm Mode the mode hand points to AL N In the...

Page 3: ...irect sunlight or in other hot areas for long periods Checking the Charge Level In the Timekeeping Mode the current charge level is indicated by the mode hand A Good high charge B Good medium charge C...

Page 4: ...uto Time Adjustment 12 30 Selection of More Than 300 World Time Cities l Configuring World Time Settings Stopwatch Data Transfer to the Phone l Viewing Stopwatch Data In addition a number of other wat...

Page 5: ...in one meter of the watch 2 X Press C SET flashes to indicate that the watch has started the connection operation Once the watch and phone are connected OK will appear and then the watch will adjust i...

Page 6: ...ill appear on the display momentarily and then the watch will return to the mode it was in before you started the connection procedure Trying to connect Connected 3 Y Perform the operation shown on th...

Page 7: ...IFICE Connected Configuring the Summer Time Setting 1 Y Tap the EDIFICE Connected icon 2 X Hold down C for at least 1 5 seconds until CONNECT starts to flash When a connection is established between t...

Page 8: ...Watch Settings Timer start time and other settings can also be configured using EDIFICE Connected 1 Y Tap the EDIFICE Connected icon 2 X Hold down C for at least 1 5 seconds until CONNECT starts to f...

Page 9: ...ocation where auto signal receive or connection with a phone may cause problems you can perform the procedure below to disable it To re enable auto time adjustment perform the same operation again 1 X...

Page 10: ...e checking the difference between the lap time and a target time Using a Stopwatch Target Time Specifying a Target Time You can specify one of three target times FASTEST Following start of a stopwatch...

Page 11: ...an view lap times with EDIFICE Connected after the race is over l Lap Times Before a race At this time you should specify the target time type If you specify TARGET as the target value type you should...

Page 12: ...t displayed until you press E The difference between the current lap time and the target time is also indicated E Start E Lap 1 E A Goal Lap 2 Lap 3 Note Lap times can be viewed with EDIFICE Connected...

Page 13: ...e E to select the alarm type DAILY Alarm sounds every day at the alarm time 1TIME Alarm sounds only once at the alarm time SCHEDULE Alarm sounds on the specified date l Setting a Schedule Alarm 8 Pres...

Page 14: ...or hourly time signal 2 Press A to toggle the displayed alarm or the hourly time signal between on and off Note Note that you will not be able to turn on a SCHEDULE alarm whose date has already passed...

Page 15: ...ome Time Home Time After swapping Before swapping Note This function comes in handy when you need to move to another time zone For details about how to use it go to the section below l Moving to Anoth...

Page 16: ...Home City is displayed Home City 2 Press D eight times This causes 12H or 24H to flash on the display 3 Press E to toggle the setting between 12H 12 hour timekeeping or 24H 24 hour timekeeping 24 hou...

Page 17: ...nd This is due to operation of the auto light switch which determines the current orientation of the watch It does not indicate malfunction Note Auto Light is disabled when any one of the conditions b...

Page 18: ...s A to exit the setting screen Other Settings Getting Ready Enter the Timekeeping Mode l Navigating Between Modes Enabling the Button Operation Tone Use the procedure below to enable or disable the to...

Page 19: ...time Destination time l Using EDIFICE Connected to Configure Settings l Using Watch Operations to Configure Settings After Arriving 1 Enable auto time adjustment l Using the Watch in a Medical Facili...

Page 20: ...ch 02 00 first Sunday in November Halifax 02 00 second Sunday in March 02 00 first Sunday in November St John s 02 00 second Sunday in March 02 00 first Sunday in November Rio de Janeiro 00 00 third S...

Page 21: ...by other devices electrical devices audio visual equipment office equipment etc In particular it can be affected by operation of a microwave oven The watch may not be able to communicate normally wit...

Page 22: ...n Disable I can t reconnect the watch and phone Q1 The watch will not re connect with the phone after they are disconnected Is EDIFICE Connected running The watch cannot re connect with the phone unl...

Page 23: ...djustment is complete Q2 Auto time adjustment is not performed at a scheduled time Is auto time adjustment not being performed according to its normal schedule Note that auto time adjustment is not pe...

Reviews: