Digital Flow Meter 

HB4087-01 

March 2018 

 

Summary of Contents for HB4087-01

Page 1: ...R MANUAL www casellasolutions com Casella Regent House Wolseley Road Kempston Bedford MK42 7JY T 44 0 1234 844 100 F 44 0 1234 841 490 E info casellasolutions com Digital Flow Meter HB4087 01 March 20...

Page 2: ...Detective 2 Contents Safety and warnings 3 Disclaimer 4 Introduction 5 Controls and fittings 6 Operation 8 Settings menu 16 Technical specifications 19 Declarations 20 Servicing maintenance and suppor...

Page 3: ...to Casella or a Casella approved service centre CAUTION If the equipment is likely to come into contact with aggressive substances take precautions to prevent the instrument from being adversely affe...

Page 4: ...from those in the manual If there are any questions please contact Casella for clarification Casella makes continual advancements in its products and services We therefore reserve the right to make ch...

Page 5: ...will control both the Apex2 and Flow Detective and automatically calibrate to selected flow rates making calibration very quick Flow Detective Plus models will also allow calibration at lower flows 20...

Page 6: ...ge values The On Off button which is used to turn the flow meter on and off and to return to a previous screen The enter key which is used to enter sub menu items and to save changed values This is th...

Page 7: ...is fitted at all times as it helps to guard against knocks If you need to decontaminate the flow meter remove the boot temporarily Note The green rubber boot must not be fitted to intrinsically safe...

Page 8: ...hboard screen showing instant and average flow From this point when air is run through the flowmeter it will display instantaneous and average flow as shown on the dashboard screen below Press to swit...

Page 9: ...rger station and power supply A USB cable for upgrading firmware of the unit is also supplied Note A fully charged battery will last in excess of 70 hours of continuous operation To charge the flow me...

Page 10: ...s shown below Manual pump calibration Manual pump calibration is to use the Flow Detective with a standard pump from any manufacturer and uses the display of the Flow Detective to view the flow 1 Swit...

Page 11: ...pulsation to be as small as possible The Flow Detective displays a red indicator if pulsation is above 10 as shown below It is a requirement for medium flow pumps to maintain pulsation below 10 under...

Page 12: ...d prior if you are calibrating the pump prior to doing the air sampling measurement The pump should be adjusted to the desired flow rate and the option checked in Step 2 below When emailing from Airwa...

Page 13: ...wait until the average flow has stabilised but do not adjust the flow rate of the pump Press to stop the post run check 3 The background on the Airwave screen will go green to show calibration is com...

Page 14: ...check Calibration This option should be checked prior if you are calibrating the pump prior to doing the air sampling measurement Airwave will automatically adjust the flow rate of the pump to the des...

Page 15: ...t This will change the flow rate set on the pump Then press to begin calibration Click Abort to stop the calibration 4 The Apex2 will now be automatically calibrated by the Flow Detective Airwave will...

Page 16: ...lues and press to go back without saving changes Note If no buttons are pressed when in the settings menu for a certain ammount of time the unit will exit the settings menu and default back to the flo...

Page 17: ...Portuguese Spanish Italian German French and Chinese Temperature units Change temperature units from Celsius C Fahrenheit F or Kelvin K Pressure units Pressure unit scan be changed between mBar psi k...

Page 18: ...rotate 180 when the unit is held horizontally and rotated Bluetooth Enable or disable Bluetooth Plus model only You need to enable Bluetooth when using the Airwave App Information Use this to see the...

Page 19: ...me 1 to 60 seconds Physical Display Colour OLED Controls 4 buttons Dimensions 112 x 37 x 102 mm 4 41 x 1 46 x 4 02 inches Weight 372g including boot Environmental Temperature Operation 0 to 45 C Stora...

Page 20: ...approvals certificates may be obtained from Casella or Bluegiga This product contains an FCC and Industry Canada certified Bluetooth Low Energy wireless transmission module FCC IDENTIFIER QOQBLE113 I...

Page 21: ...ons com WEEE INFORMATION FOR EU MEMBER STATES ONLY The use of the WEEE symbol indicates that this product may not be treated as household waste By ensuring this product is disposed of correctly you wi...

Page 22: ...ons com or contact an approved servicing distributor We will be happy to provide quotations for individual repairs or provide annual maintenance under contract Maintenance The Flow Detective is design...

Page 23: ...etective Kit Part Numbers Description Flowdetectivekit Kit includes Flow Detective kit case charger and calibration adaptor Flowdetectivepluskit Kit includes Flow Detective Plus kit case charger and c...