HYDRAULIC, PNEUMATIC, ELECTRICAL, ELECTRONIC SYSTEMS - PRIMARY HYDRAULIC POWER SYSTEM
Control valve - General specification Mechanical Hand Control
Loader valve on all models
SR130, SR150, SR175, SV185, SR200
Main Relief Setting:
3000 psi
(+145/-0) at
23 US gpm
(A1) 3263 psi
(+145/-73)
(B2) 3336 psi
(+145/-73)
Circuit Relief Setting:
(A2) 3481 psi
(+145/-73)
Loader Spool:
28 lb
Loader Spool Detent Position:
65 lb
IN;
58 lb
OUT
Bucket Spool:
29 lb
Maximum Spool Force with Blocked
Ports at Full Flow:
Minimum reserve force on all spools to be greater than
5 lb
Operating Voltage =
14 V
Maximum Power =
22 W
Electrical Requirements:
Polarity = Power: Pin 1 or A, Ground: Pin 2 or B
Work port lockout solenoid: Deutsche DT series
EH Auxiliary PRV: Deutsche DT series.
Electrical Connector Types:
Spool position sensor: Deutsche DT series
Operating Temperature Range:
-30 - 107 °C
(
-22 - 225 °F
)
(P)
Supply Inlet
(T)
Tank Return
(A1)
Lift Cylinder Base End
(B1)
Lift Cylinder Rod End
(A2)
Tilt Cylinder Rod End
(B2)
Tilt Cylinder Base End
(A3)
Auxiliary Male Coupler
(B3)
Auxiliary Female Coupler
(PLV)
Work port Lockout Pilot Supply
(PLV)
(Drain) Work port Lockout Tank Return
(P2)
High Flow Inlet
(V)
EH PRV Supply
Port Identification Chart:
(L)
EH PRV Tank Return
84423866 25/07/2011
A.10.A / 18