6 - MAINTENANCE
Cylinders
A cylinder rod should be slightly oily. Check that there
are no leaks after a period of work, when the whole
hydraulic system is at normal operating temperature.
1.
Wipe clean the rod and bearing on the cylinder to
be cleaned.
2.
Operate normally for
5 – 10 min
.
3.
Extend the cylinder rod.
4.
Carry out the leak test.
ROD APPEARANCE
TEST
CONCLUSION
Dry
Slight traces of oil when a piece of paper is
wiped over
20 cm
(
7.9 in
) of the rod.
Normal
Slightly greasy
Paper remains stuck to rod when run over rod.
Normal
Oily
Paper remains stuck when placed on rod.
Normal
Very oily or weeping
Each time the cylinder rod is extended, a ring of
oil can be seen on the rod.
Leakage
Each time the rod retracts, the excess oil drips
from the gland.
Consult your CASE
CONSTRUCTION Dealer
Plastic and resin parts
Use a soft, slightly humid, cloth to clean the panels, the
consoles, and the switches. Use a soft, dry cloth to
clean the instrument cluster.
NOTICE:
do not use gasoline, kerosene, paint solvents.
The use of gasoline, kerosene, paint solvents, etc. will
cause discoloration, cracks or deformation of the parts.
6-83
Summary of Contents for CX490D
Page 8: ......
Page 40: ...2 SAFETY INFORMATION SMIL20CEX0681HB 2 2 18 ...
Page 81: ...3 CONTROLS AND INSTRUMENTS Rear camera view operating mode SMIL19CEX2626HB 5 3 29 ...
Page 154: ...3 CONTROLS AND INSTRUMENTS 3 102 ...
Page 178: ...4 OPERATING INSTRUCTIONS 4 24 ...
Page 243: ...6 MAINTENANCE Bucket cylinder bottom pin one grease fitting SMIL15CEXY538AB 7 6 49 ...
Page 298: ...8 SPECIFICATIONS Working ranges CX490D LC SMIL19CEX2007HB 5 8 10 ...
Page 300: ...8 SPECIFICATIONS Working ranges CX490D RTC SMIL19CEX2008HB 6 8 12 ...
Page 302: ...8 SPECIFICATIONS Working ranges CX500D LC SMIL19CEX2009HB 7 8 14 ...
Page 304: ...8 SPECIFICATIONS Working ranges CX500D RTC SMIL19CEX2010HB 8 8 16 ...
Page 366: ...9 ACCESSORIES 9 60 ...