6 - MAINTENANCE
Every 2000 hours
Travel reduction units oil
Replace the travel reduction units oil every
2000 h
(After
250 h
of operation in run-in period)
Lubricant:
T
UTELA
H
YPOIDE
EP G
EAR LUBE
SAE 80W-90
Quantity:
15 L
(
4.0 US gal
) (per travel reduction gear)
1. Park the machine on flat, horizontal ground.
2. Move the machine so that the drain plug
(1)
comes
down to the lowest position.
3. Stop the engine, and remove the starter key.
4. Place a container with an appropriate capacity under
the travel reduction gear.
5. Remove the level plug
(2)
.
6. Remove the drain plug
(1)
.
NOTE:
Check the condition of the drained oil. If there are
pieces of metal or foreign objects in the oil, consult the
CASE CONSTRUCTION dealer.
7. Replace the O-ring seal of the drain plug
(1)
. Insert the
drain plug
(1)
with seal tape wrapped around it. Add
oil through port
(2)
until the oil comes up to the bottom
edge of the port.
8. Replace the O-ring seal of the level plug
(2)
. Insert the
level plug
(2)
with seal tape wrapped around it.
9. Repeat steps
to
for the other travel reduction gear.
10. Run the machine slowly to check that there are no
leaks.
SMIL15CEXY509AB
1
6-58
Summary of Contents for CX490D
Page 8: ......
Page 40: ...2 SAFETY INFORMATION SMIL20CEX0681HB 2 2 18 ...
Page 81: ...3 CONTROLS AND INSTRUMENTS Rear camera view operating mode SMIL19CEX2626HB 5 3 29 ...
Page 154: ...3 CONTROLS AND INSTRUMENTS 3 102 ...
Page 178: ...4 OPERATING INSTRUCTIONS 4 24 ...
Page 243: ...6 MAINTENANCE Bucket cylinder bottom pin one grease fitting SMIL15CEXY538AB 7 6 49 ...
Page 298: ...8 SPECIFICATIONS Working ranges CX490D LC SMIL19CEX2007HB 5 8 10 ...
Page 300: ...8 SPECIFICATIONS Working ranges CX490D RTC SMIL19CEX2008HB 6 8 12 ...
Page 302: ...8 SPECIFICATIONS Working ranges CX500D LC SMIL19CEX2009HB 7 8 14 ...
Page 304: ...8 SPECIFICATIONS Working ranges CX500D RTC SMIL19CEX2010HB 8 8 16 ...
Page 366: ...9 ACCESSORIES 9 60 ...