6 - MAINTENANCE
Every 1500 hours
DEF/AdBlue® supply module filter
Replace the supply module filter every
1500 h
1. Turn the starter key to OFF position. Wait
3 min
for
SCR system to completely suck
DEF/A
D
B
LUE
®
back
into the tank.
Unlock the key cylinder
(1)
of the
DEF/A
D
B
LUE
®
tank
cover with the starter key, and turn the handle
(2)
to
open the tank cover
(3)
.
SMIL14CEX2768AB
1
2. Prepare a container with an appropriate capacity, and
loosen the supply module filter cap
(4)
.
SMIL19CEX0551AA
2
3. Remove the filter element
(5)
and the equalizing ele-
ment
(6)
.
4. Assemble the new filter element
(5)
and the equalizing
element
(6)
.
The cap should be tightened at
20 – 25 N·m
(
14.75 –
18.44 lb ft
).
5. Wipe off the spilled
DEF/A
D
B
LUE
®
with a cloth, and
then rinse the area with fresh water. Finally, blow com-
pressed air at very low pressure to clean the compart-
ment of the
DEF/A
D
B
LUE
®
tank.
6. Idle the engine for several minutes to check that there
is no leak.
SMIL19CEX0552AA
3
6-57
Summary of Contents for CX490D
Page 8: ......
Page 40: ...2 SAFETY INFORMATION SMIL20CEX0681HB 2 2 18 ...
Page 81: ...3 CONTROLS AND INSTRUMENTS Rear camera view operating mode SMIL19CEX2626HB 5 3 29 ...
Page 154: ...3 CONTROLS AND INSTRUMENTS 3 102 ...
Page 178: ...4 OPERATING INSTRUCTIONS 4 24 ...
Page 243: ...6 MAINTENANCE Bucket cylinder bottom pin one grease fitting SMIL15CEXY538AB 7 6 49 ...
Page 298: ...8 SPECIFICATIONS Working ranges CX490D LC SMIL19CEX2007HB 5 8 10 ...
Page 300: ...8 SPECIFICATIONS Working ranges CX490D RTC SMIL19CEX2008HB 6 8 12 ...
Page 302: ...8 SPECIFICATIONS Working ranges CX500D LC SMIL19CEX2009HB 7 8 14 ...
Page 304: ...8 SPECIFICATIONS Working ranges CX500D RTC SMIL19CEX2010HB 8 8 16 ...
Page 366: ...9 ACCESSORIES 9 60 ...