6 - MAINTENANCE
Swing reduction unit oil
WARNING
Hot surface possible!
Wait for all components to cool before performing any operation.
Failure to comply could result in death or serious injury.
W0251A
Replace the swing reduction unit oil every
1000 h
(After
250 h
of operation in run-in period).
Lubricant:
T
UTELA
H
YPOIDE
EP G
EAR LUBE
SAE 80W-90
.
Quantity:
10.5 L
(
2.8 US gal
).
1. Park the machine on a flat and level place. Stop the
engine, and remove the starter key.
2. Remove the oil gauge
(1)
and the fill plug
(2)
. Clean
the oil gauge with a neat cloth.
SMIL15CEXY508AB
1
3. Remove the lower panel
(3)
.
SMIL19CEX1996AA
2
4. Place a container with an appropriate capacity under
the upper structure frame. Remove the oil drain plug
(4)
to drain oil.
NOTE:
Draining oil requires a comparatively long time.
NOTE:
Check the condition of the drained oil. If foreign
objects, such as metal scrapings, are included, consult the
CASE CONSTRUCTION dealer.
SMIL15CEXY666AA
3
6-54
Summary of Contents for CX490D
Page 8: ......
Page 40: ...2 SAFETY INFORMATION SMIL20CEX0681HB 2 2 18 ...
Page 81: ...3 CONTROLS AND INSTRUMENTS Rear camera view operating mode SMIL19CEX2626HB 5 3 29 ...
Page 154: ...3 CONTROLS AND INSTRUMENTS 3 102 ...
Page 178: ...4 OPERATING INSTRUCTIONS 4 24 ...
Page 243: ...6 MAINTENANCE Bucket cylinder bottom pin one grease fitting SMIL15CEXY538AB 7 6 49 ...
Page 298: ...8 SPECIFICATIONS Working ranges CX490D LC SMIL19CEX2007HB 5 8 10 ...
Page 300: ...8 SPECIFICATIONS Working ranges CX490D RTC SMIL19CEX2008HB 6 8 12 ...
Page 302: ...8 SPECIFICATIONS Working ranges CX500D LC SMIL19CEX2009HB 7 8 14 ...
Page 304: ...8 SPECIFICATIONS Working ranges CX500D RTC SMIL19CEX2010HB 8 8 16 ...
Page 366: ...9 ACCESSORIES 9 60 ...