6 - MAINTENANCE
Hydraulic tank breather
Replace the hydraulic tank breather every
1000 h
1. Keep pressed the button
(1)
on the top of the breather
to release all the pressure in the hydraulic tank.
2. Clean the top surface of the hydraulic tank.
SMIL19CEX0597AA
1
3. Remove the button
(1)
from the breather.
4. Remove the nut
(2)
and the cover
(3)
.
5. Remove and discard the used filter element
(4)
.
6. Attach a new element
(4)
with the seal
(5)
facing up.
7. Attach the cover
(3)
together with the nut
(2)
.
8. Attach the button
(1)
.
SMIL14CEX2782BB
2