![Case CX300C Operator'S Manual Download Page 225](http://html1.mh-extra.com/html/case/cx300c/cx300c_operators-manual_2567381225.webp)
6 - MAINTENANCE
Air filter
Inspection
Be sure to carry out regular checks on the air filter, intake manifold, seals and hoses. At the same time, check the
intake manifold screws and hose clamps for tightness.
The hoses should be changed before they are worn.
Service specifications
Inspect and clean the primary element: Every 250 hours or when the "Air filter" message is displayed on the message
display screen
Replace the primary element: Every 1000 hours or after cleaning 6 times
Replace the secondary element: Every 1000 hours or after cleaning the main element 3 times
ATTENTION:
The primary element can be cleaned. The secondary element cannot be cleaned and must be changed.
NOTICE:
Observe the air filter service intervals shown above. Clean filters mean longer engine life.
Removing the elements
1. Release the fasteners and remove the cover.
1Y9VUP-001
1
2. Remove the primary element.
1Y9VUP-002
2
6-43