![Case 621G Stage IV Original Instructions Manual Download Page 354](http://html.mh-extra.com/html/case/621g-stage-iv/621g-stage-iv_original-instructions-manual_2567290354.webp)
7 - MAINTENANCE
Auxiliary battery connections - Check
WARNING
Improper operation or service of this machine can result in an accident.
An error connecting auxiliary starting cables or short-circuiting battery terminals can cause an acci-
dent. Connect auxiliary starting cables as instructed in this manual.
Failure to comply could result in death or serious injury.
W0263A
DANGER
Explosion hazard!
Read "Connecting booster battery" procedure completely before attempting to jump-start or service
a battery.
Failure to comply will result in death or serious injury.
D0086A
WARNING
Explosion hazard!
Booster batteries or jumper cables must be connected properly to prevent battery explosion and/or
damage to the electrical system. Connect positive to positive and negative to negative.
Failure to comply could result in death or serious injury.
W0343A
Make sure that the voltage of the booster batteries is
the same as that of the machine system (
12 V
each
battery).The batteries are located on the left-hand side
of the machine.
1. Turn off the ignition and all accessories on the machine.
Remove the battery cover from left-hand side of the
machine. Remove the battery terminal covers.
2. Identify the discharged battery.
3. Connect one end of the positive (+) cable to the positive
(+) terminal on the booster battery. Connect the other
end of the positive (+) cable to the positive (+) terminal
of the discharged battery.
4. Connect the negative (-) cable to the negative (-) termi-
nal on the booster battery.
5. Connect the other end of the negative cable to the en-
gine block or frame of the machine with the discharged
battery. Do not connect to the negative terminal on the
battery.
NOTICE:
do not connect the other end of the negative ca-
ble to sheet metal or any rotating part, as damage can re-
sult.
6. Start the engine.
7. Remove the booster battery negative (-) cable from the
machine, then from the booster battery. Remove the
positive (+) cable from the machine and then from the
booster battery.
8. Install the terminal covers.
LEIL16WHL0550AA
1
7-146
Summary of Contents for 621G Stage IV
Page 42: ...2 SAFETY INFORMATION Empty tool LEEN11T0024AA 20 2 22 ...
Page 60: ...2 SAFETY INFORMATION 2 40 ...
Page 137: ...3 CONTROLS AND INSTRUMENTS Inducement and validation re starts LEIL14WHL0394HA 2 3 77 ...
Page 138: ...3 CONTROLS AND INSTRUMENTS Validation re start procedure LEIL15WHL0608HA 3 3 78 ...
Page 150: ...3 CONTROLS AND INSTRUMENTS 3 90 ...
Page 166: ...4 OPERATING INSTRUCTIONS RCPH10WHL045BAH 7 4 16 ...
Page 168: ...4 OPERATING INSTRUCTIONS RCPH10WHL045BAH 9 4 18 ...
Page 170: ...4 OPERATING INSTRUCTIONS RCPH10WHL045BAH 12 4 20 ...
Page 208: ...6 WORKING OPERATIONS 6 18 ...
Page 229: ...7 MAINTENANCE DEF AdBlue technical faults LEIL14WHL0392HA 4 7 21 ...