![Case 621G Stage IV Original Instructions Manual Download Page 337](http://html.mh-extra.com/html/case/621g-stage-iv/621g-stage-iv_original-instructions-manual_2567290337.webp)
7 - MAINTENANCE
As required
Fuel pre-filter - Drain fluid
Drain water and sediment from the fuel pre-filter as required. In certain geographic regions and climates, it may be
necessary to drain condensation more frequently.
Prior operation:
Park the machine on a firm, level surface. Lower the attachment to the ground. Apply the parking brake, and install
the transport service link to prevent unexpected articulation movements.
Drain fuel filter condensation
1. Open the engine hood. Locate the pre-filter on the
right-hand side of the machine.
2. Remove the connector. Open the drain valve on the
fuel pre-filter by turning counterclockwise two or three
turns. Drain the water and/or contaminants from the
pre-filter into a suitable container until clean fuel flows.
Do not allow fuel to spill on engine or ground.
3. Close the drain valve. Reconnect the electrical con-
nection. Check for leaks.
NOTE:
if it is necessary to bleed the fuel system, use the
attached pump and the bleed screw at the top of the pre-
filter housing.
RCPH10WHL900AAH
1
7-129
Summary of Contents for 621G Stage IV
Page 42: ...2 SAFETY INFORMATION Empty tool LEEN11T0024AA 20 2 22 ...
Page 60: ...2 SAFETY INFORMATION 2 40 ...
Page 137: ...3 CONTROLS AND INSTRUMENTS Inducement and validation re starts LEIL14WHL0394HA 2 3 77 ...
Page 138: ...3 CONTROLS AND INSTRUMENTS Validation re start procedure LEIL15WHL0608HA 3 3 78 ...
Page 150: ...3 CONTROLS AND INSTRUMENTS 3 90 ...
Page 166: ...4 OPERATING INSTRUCTIONS RCPH10WHL045BAH 7 4 16 ...
Page 168: ...4 OPERATING INSTRUCTIONS RCPH10WHL045BAH 9 4 18 ...
Page 170: ...4 OPERATING INSTRUCTIONS RCPH10WHL045BAH 12 4 20 ...
Page 208: ...6 WORKING OPERATIONS 6 18 ...
Page 229: ...7 MAINTENANCE DEF AdBlue technical faults LEIL14WHL0392HA 4 7 21 ...
Page 370: ...7 MAINTENANCE 7 162 ...