Loader bucket - self-leveling adjustment (Bent arm)
Models without straight loader arm
The “return-to-dig” device is an electrically activated
feature which enables the operator to automatically
return the bucket to a level digging position for a further
work cycle, with one simple movement of the control
lever
(3)
.
Whenever the bucket is rolled forward to dump the re-
turn-to-dig electric circuit is completed and the solenoid
on the bucket spool is energized.
When the loader bucket control lever
(3)
is moved di-
agonally left to the return-to-dig position
(2)
the electro-
magnet will hold the bucket spool in the roll back po-
sition until the bucket is in the level digging position at
which time the indicator on the rod of the bucket linkage
will pass in front of the sensor which de-energizes the
electromagnet on the bucket spool enabling the spool
to return to the neutral position.
LEEN12T0585AA
1
Return-to-dig sensor - adjustment
1. The return-to-dig system consists of an electromagnet
mounted on the loader bucket control valve spool, a
sensor
(1)
mounted on top of the loader arm and a
pointer attached to the tube of the bucket self-levelling
linkage.
2. Place the bucket on the ground in the preferred digging
position.
3. Check the dimensions of
88.5 mm
(
3.48 in
) and
7.5 mm
(
0.29 in
) are maintained as shown.
4. Ensure that the face of the sensor
(1)
is
6 mm
(
0.23 in
)
from the rod
(2)
.
LEEN12T0511AA
2
NOTE:
As a visual aid for the operator, while seated in the cab, the pointer mounted on the loader arm can be seen
to align with the pointer on the return-to-dig linkage, when the loader arms are lowered and the bucket is in the level
digging position.
7-138
Summary of Contents for 580ST
Page 8: ......
Page 24: ...1 GENERAL INFORMATION 1 16 ...
Page 49: ...2 SAFETY INFORMATION Extend telescopic dipper If fitted MOLI12LBB0092AA 24 2 25 ...
Page 101: ...3 CONTROLS AND INSTRUMENTS Setup menu LEIL12TLB00006I 1 3 39 ...
Page 144: ...3 CONTROLS AND INSTRUMENTS 3 82 ...
Page 164: ...4 OPERATING INSTRUCTIONS 4 20 ...
Page 166: ...5 TRANSPORT OPERATIONS RAIL14TLB1181GA 1 5 2 ...
Page 222: ...6 WORKING OPERATIONS 6 44 ...
Page 247: ...7 MAINTENANCE Fuel tank capacity 145 L 38 30 US gal 2WS 124 L 32 76 US gal 4WS 7 25 ...
Page 347: ...7 MAINTENANCE Fuses and relays Powershift cab 2WS MOLI12LBB0491CA 7 7 125 ...
Page 349: ...7 MAINTENANCE Fuses and relays Powershift cab 4WS MOLI12LBB0492CA 8 7 127 ...
Page 390: ...8 TROUBLESHOOTING 8 28 ...
Page 418: ...9 SPECIFICATIONS 4WS LEEN11T0039FA 2 9 28 ...
Page 420: ...9 SPECIFICATIONS 2WS 590ST LEEN11T0041FA 5 4WS 695ST LEEN11T0042FA 6 9 30 ...
Page 433: ......