7 - MAINTENANCE
Hydraulic oil level
1. Move the machine to a level and firm ground.
2. Lower the loader attachment to the ground.
3. Place the backhoe attachment in the road travel posi-
tion.
4. Place the direction-of-travel lever and gearshift lever in
neutral position.
5. Immobilize the machine with the parking brake.
6. Stop the engine and remove the starter switch key.
7. Release any possible residual pressure from the hy-
draulic system by moving the control levers in all direc-
tions.
8. Lock the attachment controls (specific to certain coun-
tries).
LEEN11T0362AA
1
9. Check the hydraulic oil level in the tank
(1)
through the
level gauge
(3)
after waiting for the oil to cool down,
reaching the ambient temperature.
10. The hydraulic oil level must reach at least the half of
the gauge
(3)
.
11. If necessary, top up.
NOTICE:
Even when its level is insufficient, a small quan-
tity of hydraulic oil remains in the lower part of the gauge.
This does not mean that the level is sufficient.
LEEN11T0349AA
2
Oil specification
NOTICE:
Oil quality and cleanliness are of utmost impor-
tance for the reliability and life of the hydraulic system. De-
viation from the prescribed oil specification may lead to se-
vere damage and void warranty.
Use
CASE AKCELA NEXPLORE™ FLUID
,
MAT 3525
or an oil meeting the following specification:
•
API GL-4
•
ISO VG-32/46
•
SAE 10W30
•
DIN 51524 P
ART
3
HV46
•
ISO VG-46
or use
T
UTELA
HYDROSYSTEM AW 46
, MAT 3508 or
an oil meeting the following specification:
•
DIN 51524 P
ART
3
HV46
•
ISO VG-46
7-22
Summary of Contents for 580ST
Page 8: ......
Page 24: ...1 GENERAL INFORMATION 1 16 ...
Page 49: ...2 SAFETY INFORMATION Extend telescopic dipper If fitted MOLI12LBB0092AA 24 2 25 ...
Page 101: ...3 CONTROLS AND INSTRUMENTS Setup menu LEIL12TLB00006I 1 3 39 ...
Page 144: ...3 CONTROLS AND INSTRUMENTS 3 82 ...
Page 164: ...4 OPERATING INSTRUCTIONS 4 20 ...
Page 166: ...5 TRANSPORT OPERATIONS RAIL14TLB1181GA 1 5 2 ...
Page 222: ...6 WORKING OPERATIONS 6 44 ...
Page 247: ...7 MAINTENANCE Fuel tank capacity 145 L 38 30 US gal 2WS 124 L 32 76 US gal 4WS 7 25 ...
Page 347: ...7 MAINTENANCE Fuses and relays Powershift cab 2WS MOLI12LBB0491CA 7 7 125 ...
Page 349: ...7 MAINTENANCE Fuses and relays Powershift cab 4WS MOLI12LBB0492CA 8 7 127 ...
Page 390: ...8 TROUBLESHOOTING 8 28 ...
Page 418: ...9 SPECIFICATIONS 4WS LEEN11T0039FA 2 9 28 ...
Page 420: ...9 SPECIFICATIONS 2WS 590ST LEEN11T0041FA 5 4WS 695ST LEEN11T0042FA 6 9 30 ...
Page 433: ......