7 - MAINTENANCE
Hydraulic reservoir breather
Change the breather for the hydraulic reservoir after 1000
hours of operation.
1.
Clean the areas around the top of the hydraulic reser-
voir, including the breather and the hydraulic tubing
above the breather.
RCPH10TLB427AAF
1
2.
Slowly remove the fill cap for the hydraulic reservoir.
3.
After pressure is released, replace the reservoir cap.
RCPH10TLB428AAF
2
4.
Remove and discard the breather from the hydraulic
reservoir tank. Turn counter-clockwise to unscrew.
5.
Ensure the o-ring is seated correctly in the new
breather and install the new breather in the hydraulic
reservoir tank.
Turn clockwise to tighten.
Hand
tighten or tighten to approximately
10 N·m
(
7.4 lb ft
).
RCPH10TLB427AAF
3