7 - MAINTENANCE
Air conditioning compressor seals
Run the air conditioning to lubricate the compressor seals
every 250 hours of operation.
1.
WARNING
Rotating parts!
The engine is running. Keep clear of ro-
tating fans and belts.
Failure to comply could result in death or
serious injury.
W0275A
Start up the engine. The engine must be running for
this procedure.
2.
In temperatures below
0 °C
(
32 °F
), put a cover over
the air conditioning condenser. This ensures the re-
frigerant and lubricants in the system are at operating
temperature.
3.
Turn the air conditioning control to the maximum set-
ting and run for at least 15 minutes.
7-67