6 - MAINTENANCE
Travel reduction gears
Replace the travel reduction gears oil every
1000 h
(After
500 h
of operation in run-in period)
Lubricant:
CASE AKCELA GEAR 135 H EP 80W-90
Quantity:
0.5 L
(
0.1 US gal
) (per travel reduction gear)
1. Park the machine on flat, horizontal ground.
2. Move the machine so that the drain plug
(1)
comes
down to the lowest position.
3. Stop the engine, and remove the starter key.
4. Place a container with an appropriate capacity under
the travel reduction gear.
5. Remove the level plug
(2)
.
6. Remove the drain plug
(1)
.
NOTE:
check the condition of the drained oil. If there are
pieces of metal or foreign objects in the oil, consult the
CASE CONSTRUCTION dealer.
7. Replace the O-ring seal of the drain plug
(1)
.
8. Insert the drain plug
(1)
with seal tape wrapped around
it.
9. Replace the O-ring seal of the level plug
(2)
and the
O-ring seal of the fill plug
(3)
. Insert the level plug
(2)
with seal tape wrapped around it, then do the same for
the fill plug
(3)
.
10. Add oil through fill port
(3)
until the oil comes up to the
bottom edge of the port
(2)
.
11. Repeat steps
2
to
10
for the other travel reduction
gear.
12. Run the machine slowly to check that there are no
leaks.
SMIL16MEX1456AA
1
6-47
Summary of Contents for CX37C