6 - MAINTENANCE
Hydraulic oil level
WARNING
Burn hazard!
Before performing any service on the hydraulic system, you must allow it to cool. Hydraulic fluid
temperature should not exceed 40 °C (104 °F).
Failure to comply could result in death or serious injury.
W0241A
Check the hydraulic oil level every
10 h
or every day
Fluid:
CASE AKCELA HYDRAULIC LL 46
1. Park the machine on a flat and level place, and arrange
the attachment as shown in the figure. Stop the engine,
and remove the starter key.
SMIL16MEX0376AA
1
2. Open the side hood to access the hydraulic oil tank
(3)
.
The oil level is normal if between the red lines of the
level gauge
(1)
.
3. If the hydraulic oil level is not in the correct range pro-
ceed as follows:
• Release all pressure in the hydraulic tank. Refer to
page
6-11
• Clean the cap
(2)
and the area around the cap.
• Remove the cap
(2)
, and supply hydraulic fluid to the
hydraulic oil tank.
• Install the cap
(2)
.
NOTICE:
make sure that no contaminant (water, sand etc.)
enters the reservoir during filling.
SMIL16MEX1451AA
2
4. Start the engine after filling and operate the work equip-
ment several times.
5. Check the oil level after engine stops. Close the side
hood.