C.5 Restrictions on Use of S-Registers
S-registers 6, 7, 8 and 36 must always comply with the statutory
requirements listed below. Settings which do not conform are overridden
and the minimum or maximum setting is reverted to.
S-REGISTER
MINIMUM VALUE
MAXIMUM VALUE
S6
Wait for dialtone
S7
Wait for carrier
S8
Pause time for comma
S36
Max. No. of dial attempts
4 seconds
0 seconds
4 seconds
1 attempt
8 seconds
59 seconds
8 seconds
7 attempts
The use of multiple commas in a dialling string does not override the 8-
second statutory maximum in registers S6 and S8.