S56 Constant Carrier Timeout
Timer
Range: 0-255 (seconds)
Default: 30 (seconds)
This register contains the period of time, after loss of constant
carrier, before the incoming call is disconnected (*T command).
Timeout is disabled when the register is set at 0.
S93 V.42bis Dictionary Size
Counter
Range: 9-12
Default: 11 (2048 bytes)
This register sets the V.42bis dictionary size as follows:
Register
Dictionary Size (bytes)
9
512
10
1024
11
2048
12
4096
A dictionary size of 4096 bytes is only available when one-way
compression is used (
%C2
or
%C3
).
S94 V.42bis Maximum String Length
Counter
Range: 6-250 (bytes)
Default: 40 (bytes)
This register sets the maximum length of the string used in the
V42bis compression algorithm.
As a general guide, for text files use a large dictionary size and large
(e.g. 40) maximum string length. For binary files, use a small
dictionary size and small maximum string length.
X460-306851 Issue 1
9-7
Rev.0
Summary of Contents for Mayze 24
Page 10: ...X460 306851 Issue 1 0 10 Rev 0...
Page 12: ...X460 306851 Issue 1 1 2 Rev 0...
Page 20: ...X460 306851 Issue 1 1 10 Rev 0...
Page 38: ...X460 306851 Issue 1 3 8 Rev 0...
Page 40: ...X460 306851 Issue 1 4 2 Rev 0...
Page 76: ...X460 306851 Issue 1 5 16 Rev 0...
Page 124: ...X460 306851 Issue 1 8 32 Rev 0...
Page 132: ...X460 306851 Issue 1 9 8 Rev 0...
Page 142: ...X460 306851 Issue 1 A 4 Rev 0...
Page 148: ...X460 306851 Issue 1 B 6 Rev 0...
Page 158: ...X460 306851 Issue 1 C 10 Rev 0...
Page 166: ...X460 306851 Issue 1 D 8 Rev 0...