S40 Flow Control XOFF Character
ASCII
Range: 0-127
Default: 19H (ASCII DC3)
This register contains the XOFF character used in XON/XOFF flow
control (DC3 = Ctrl-S).
S41 Secondary XON character
ASCII
Range: 0-255
Default: F9H
This register contains the secondary XON character used in dual flow
control.
S42 Secondary XOFF character
ASCII
Range: 0-255
Default: FBH
This register contains the secondary XOFF character used in dual
flow control.
S43 Dialback Security Enable
ASCII
Range: 0 or 255 Default: 0
When S43=0, dialback security is disabled. When S43=255,
dialback security is enabled. No other values are valid.
S49 User Flow Control XON Character
ASCII
Range: 0-255
Default: 17H (ASCII DC1)
This register contains the XON character used in user XON/XOFF
flow control (DC1 = Ctrl-Q).
S50 User Flow Control XOFF Character
ASCII
Range: 0-255
Default: 19H (ASCII DC3)
This register contains the XOFF character used in user XON/XOFF
flow control (DC3 = Ctrl-S).
X460-306851 Issue 1
9-6
Rev.0