9.3 Non-Bit-Mapped S-Registers
S0
Answer After Specified Number of Rings, or Disable Auto-
answer
Counter
Range: 0-255
Default: 2
The number entered in the S0 register determines the number of
times an incoming call signal is received, before the call is answered.
If S0 is set at 0, the autoanswer facility is disabled.
S1
Ring Counter
Counter
Range: 0-255
Default: 0
This register records the number of incoming ring signals detected.
It cannot be over-written by the user.
S2
Escape Character
ASCII
Range: 0-127
Default: 43H (ASCII
+
)
This register contains the code interpreted as the AT escape
character.
S3
Carriage Return Character
ASCII
Range: 0-127
Default: 13H (ASCII CR)
This register contains the code interpreted, and output, as the
carriage return character, when the modem is in command mode.
S4
Line Feed Character
ASCII
Range: 0-127
Default: 10H (ASCII LF)
This register contains the code which is output as the line feed
character when the modem is in command mode.
S5
Backspace Character
ASCII
Range: 0-127
Default: 8 (ASCII BS)
This register contains the code that is interpreted as the backspace
character when the modem is in command mode.
X460-306851 Issue 1
9-3
Rev.0
Summary of Contents for Mayze 24
Page 10: ...X460 306851 Issue 1 0 10 Rev 0...
Page 12: ...X460 306851 Issue 1 1 2 Rev 0...
Page 20: ...X460 306851 Issue 1 1 10 Rev 0...
Page 38: ...X460 306851 Issue 1 3 8 Rev 0...
Page 40: ...X460 306851 Issue 1 4 2 Rev 0...
Page 76: ...X460 306851 Issue 1 5 16 Rev 0...
Page 124: ...X460 306851 Issue 1 8 32 Rev 0...
Page 132: ...X460 306851 Issue 1 9 8 Rev 0...
Page 142: ...X460 306851 Issue 1 A 4 Rev 0...
Page 148: ...X460 306851 Issue 1 B 6 Rev 0...
Page 158: ...X460 306851 Issue 1 C 10 Rev 0...
Page 166: ...X460 306851 Issue 1 D 8 Rev 0...