19
|
P a g e
INSTALLATION
P
OWER
S
OURCE
R
EQUIREMENTS
When selecting a location for the oven, verify each of the following requirements is satisfied:
Power Source:
The power source must match the voltage and amperage requirements listed on the
unit data plate.
•
The unit is intended for 50/60 Hz applications at the following amperage:
Model
AC Voltage
Amperage
SVO-5-VC
220 – 240
20
•
The power source must be protective earth grounded and single phase.
•
The power source must conform to all national and local electrical codes.
•
The unit may be damaged if the supplied voltage varies by more than 10% from the data
plate rating.
•
A dedicated separate circuit for the oven is recommended to prevent possible loss of
product due to overloading or failure of other equipment on the same circuit.
•
A switch or circuit-breaker must be used in the building installation
to protect against
overcurrent conditions.
o
The recommended circuit-breaker for the wall power source is
25 amps.
Power Feed Disconnect:
The oven must be positioned so that all operators have access to the
power feed disconnect in case of emergencies.
•
The disconnect must be near the equipment and within easy reach of the operator.
•
The disconnect must be marked as the disconnecting device for the equipment.
Internal Circuit Breakers:
The oven comes equipped with multiple internal circuit breakers.
Resetting these is
a service-level procedure
. The cause of the overcurrent conditions that tripped
the breakers must be identified and repaired prior to resetting.