CARVIN® POOL EQUIPMENTS
4
PACKAGE CONTENT
ID Description
Qty
1
Control Panel
1
2
Electrolysis Cell
1
3
Union
2
-
User Manual
1
-
Mounting Screws
2
COMPONENTS AND CONTROLS
ID Description
1
Cell Cable Connector
2
Display
3
DOWN Button
4
UP Button
5
Mode Button
6
Dust Cap
7
Electrolysis Cell Cable
8
Enclosure
9
Heatsink
10 Mounting Holes
11 Power Cable
12 Socket Connector
13 Tightening Ring
14 Ventilation slots
15 Water Inlet
16 Water Outlet
FEATURES
The
OLLO™
Chlorine Generator System makes it easier than ever to maintain the water quality
in your swimming pool.
HIGH DEFINITION DISPLAY
Navigate, select options and read system status with ease of use.
BUILT-IN WATER MONITORING SENSORS
A temperature sensor and flow switch are integrated to the electrolysis cell. No extra accessories
to install or connect.
HEAVY DUTY CONNECTOR SYSTEM
Its push-lock/twist-pull keyed connector makes connecting the electrolysis cell safe and easy.
The panel mount connector located on the electrolysis cell and the included dust cap make it
easier to winterize the system.
ADVANCED MODE
Through an advanced menu, access real-time information about your system.
INSTALLATION
To reduce the risk of injury, installation and maintenance must be performed by a qualified pool
professional.
The electrical installation must be done in accordance with the Canadian Electrical Code, the
National Electrical Code (USA) or any other local or national requirements.
CONTROL PANEL
The control panel of the
OLLO™
is designed for outdoor installation. It must be installed at a
minimum distance of 1.5m (5ft) from the pool and at a minimum of 0.6m (2ft) from the ground, or
in accordance with local and national requirements.
It is designed to be mounted on a vertical, flat surface, in a ventilated area.
Two screws are provided for mounting the control panel.
Do not install horizontally or upside down. Do not obstruct the ventilation slots on the back of the
enclosure. Do not bury cord. Locate cord to minimize abuse from lawn mowers, hedge trimmers,
and other equipment.
Risk of Electric Shock. Connect only to a branch circuit
protected by a ground-fault circuit-interrupter (GFCI). Contact
a qualified electrician if you cannot verify that the circuit is
protected by a Class A GFCI.
To reduce the risk of electric shock, replace damaged cord
immediately.
The OLLO™ control panels come either with a single or dual input voltage. Both models come
with a factory installed NEMA 5-15P power cord assembly, for use on a 120V power source.
Refer to section Technical Information for details.
The OLLO™ control panel with dual voltage can be converted to operate from a 240V power
source. This conversion requires the replacement of the factory installed power cord. No jumper
or rewiring is required.
Connect the Product directly to the power source. Do not connect through an extension, relay,
timer or power strip.
WARNING
WARNING