CARVIN® POOL EQUIPMENTS 

 

 

 

PACKAGE CONTENT 

 

 

ID  Description 

Qty 

Control Panel 

Electrolysis Cell 

Union 

User Manual 

Mounting Screws 

 

COMPONENTS AND CONTROLS 

 

 

ID  Description 

Cell Cable Connector 

Display 

DOWN Button 

UP Button 

Mode Button 

Dust Cap 

Electrolysis Cell Cable 

Enclosure 

Heatsink 

10  Mounting Holes 
11  Power Cable 
12  Socket Connector 
13  Tightening Ring 
14  Ventilation slots 
15  Water Inlet 
16  Water Outlet 

 

FEATURES 

The 

OLLO™

 Chlorine Generator System makes it easier than ever to maintain the water quality 

in your swimming pool.  

HIGH DEFINITION DISPLAY 

Navigate, select options and read system status with ease of use. 

BUILT-IN WATER MONITORING SENSORS 

A temperature sensor and flow switch are integrated to the electrolysis cell. No extra accessories 

to install or connect. 

HEAVY DUTY CONNECTOR SYSTEM 

Its push-lock/twist-pull keyed connector makes connecting the electrolysis cell safe and easy. 

The panel mount connector located on the electrolysis cell and the included dust cap make it 

easier to winterize the system. 

ADVANCED MODE 

Through an advanced menu, access real-time information about your system. 

INSTALLATION 

To reduce the risk of injury, installation and maintenance must be performed by a qualified pool 

professional. 

The electrical installation must be done in accordance with the Canadian Electrical Code, the 

National Electrical Code (USA) or any other local or national requirements. 

CONTROL PANEL 

The control panel of the 

OLLO™

 is designed for outdoor installation. It must be installed at a 

minimum distance of 1.5m (5ft) from the pool and at a minimum of 0.6m (2ft) from the ground, or 

in accordance with local and national requirements. 

 

It is designed to be mounted on a vertical, flat surface, in a ventilated area. 

Two screws are provided for mounting the control panel. 

Do not install horizontally or upside down. Do not obstruct the ventilation slots on the back of the 

enclosure. Do not bury cord. Locate cord to minimize abuse from lawn mowers, hedge trimmers, 

and other equipment. 

Risk of Electric Shock. Connect only to a branch circuit 
protected by a ground-fault circuit-interrupter (GFCI). Contact 
a qualified electrician if you cannot verify that the circuit is 

protected by a Class A GFCI. 

To reduce the risk of electric shock, replace damaged cord 
immediately. 

The OLLO™ control panels come either with a single or dual input voltage. Both models come 

with a factory installed NEMA 5-15P power cord assembly, for use on a 120V power source. 

Refer to section Technical Information for details. 

The OLLO™ control panel with dual voltage can be converted to operate from a 240V power 

source. This conversion requires the replacement of the factory installed power cord. No jumper 

or rewiring is required. 

Connect the Product directly to the power source. Do not connect through an extension, relay, 

timer or power strip. 

WARNING 

WARNING 

Summary of Contents for OLLO 94180186

Page 1: ...CARVIN POOL EQUIPMENT 4000 boul Casavant Ouest Saint Hyacinthe Qu bec Canada J2S 9E3 M10103 C0 EN 2020 Le Groupe VIF Inc All rights reserved OLLO CHLORINE GENERATOR User Manual...

Page 2: ......

Page 3: ...rovided this manual Failure to follow warnings and safety messages may result in property damage or personal injury The user assumes the bodily or material risks arising from any improper use of this...

Page 4: ...an Electrical Code the National Electrical Code USA or any other local or national requirements CONTROL PANEL The control panel of the OLLO is designed for outdoor installation It must be installed at...

Page 5: ...ht the enclosure and release the pliers Position the wires on the input power terminal block Tighten the three 3 screws and secure the wires correctly in place Close the enclosure and use the two 2 sc...

Page 6: ...sconnect the OLLO system from the main power supply Gradually pour the salt into the pool water in front of the jets to facilitate dispersion and dissolution Do not add salt in or near the skimmer or...

Page 7: ...ults or when the cleaning is done reset the maintenance reminder timer by pressing the UP and DOWN buttons simultaneously In an area where water is hard rich in calcium and or minerals and in pools wh...

Page 8: ...our pool professional for analysis The electrolysis cell is dirty Refer to section Maintenance High level of chlorine The pool has recently been shocked Let the shock oxidize and wait 24 hours The sys...

Page 9: ...4 Screw phillips pan head zinc plated 6 x 5 16 4 pk 8 23 8350 04 R Transformer 9 14 0740 26 R Washer M6 10 14 1267 27 R Screw hex head M6 X 55 mm 11 23 8350 02 R Circuit board assembly LCD Display 12...

Page 10: ...sts and Normal maintenance services or water chemistry analysis service described in this manual This warranty is non transferable and applies only to the first retail buyer and only during the period...