62-11637
3–8
3.6
CHANGING SETPOINT
1. With the system powered up (START/RUN-OFF switch in the START/RUN position) or in PC Mode and the
default screen displayed (press the Back soft key if required):
2. Press the
▲
or
▼
key to bring the displayed setpoint to the desired value.
TIP
The setpoint will change one degree with each press and release of an arrow key or the setpoint will
scroll if the key is pressed and held.
3. Press the “=” key to save the new setpoint. The MessageCenter will display “SETPOINT CHANGED” for 5
seconds.
4. If the “=” key is not pressed the setpoint screen will flash, the MessageCenter will display “SETPOINT NOT
CHANGED” and then return to original setpoint.
- - - - -
By default, setpoints of -22°F to +90°F (-30°C to +32°C) may be entered using the display mounted keys. The con-
trol system always retains the last entered setpoint in memory. The setpoint will change 1° (one full degree)
OR
0.1° (one tenth of a degree - if configured to do so) for each press and release of the UP ARROW or DOWN
ARROW key.
NOTE
The control system may be configured with a minimum and/or maximum setpoint other than the
default values listed above. “MAX SETPOINT HAS BEEN REACHED” or “MIN SETPOINT HAS BEEN
REACHED” will display in the MessageCenter when either of these conditions is reached.
Setpoint may be changed any time the START/RUN - OFF switch is in the START/RUN position, or when the unit
is in PC Mode EXCEPT when:
• Viewing the Alarm List, Data List or Functional Parameters
OR
• When the unit is in Pretrip
OR
• When the unit is in Sleep Mode.
Pressing the = key will cause the new displayed setpoint value to become active and “SETPOINT CHANGED” will
be displayed. If the new value is not entered, after 5 seconds of no display mounted key activity, the entire display
and Light Bar will flash and the buzzer will be energized for 15 seconds (with “SETPOINT NOT CHANGED” dis-
played) and then revert back to the last entered setpoint. All other keys are active at this time and if pressed while
the display is flashing, will stop the flashing, and perform the requested function.
TIP
The setpoint may be changed quickly by pressing and holding the UP ARROW or DOWN ARROW
key until the desired setpoint is reached. The longer the key is held, the faster the setting will change.
CONTINUOUS
START/STOP
MENU
ALARM
COOL
DIESEL
START/STOP
INTELLISET
Viewing Menu Soft Key
Selections
Press Menu Key to Scroll
PRETRIP HOUR
METERS
UNIT
DATA
DEFROST
IntelliSets (2 of 7)
BACK
EXIT
IntelliSet Off
Banana Active
Flowers
Lettuce
Cheese
PRETRIP MENU
BACK
EXIT
Start Pretrip
View Results of Last Pretrip
COOL
DIESEL
START/STOP
STATUS OK
36
36
.2
BOX TEMPERATURE F
SETPOINT F
2
2
3
Summary of Contents for Transicold X4 7300
Page 21: ...62 11637 1 6 1 3 SAFETY DECALS ...
Page 22: ...1 7 62 11637 62 03958 ...
Page 23: ...62 11637 1 8 ...
Page 24: ...1 9 62 11637 ...
Page 119: ...62 11637 SECTION 6 MESSAGECENTER PARAGRAPH NUMBER Page 6 1 MESSAGECENTER MESSAGES 6 1 ...
Page 278: ......