NOTE
For PCMCIA sRAM cards, the display will show "SEt UP" when unit turns on.
6. Use the Arrow keys until the display shows “LOAd 53XX” and press the ENTER key.
7. The display will alternate between the messages “PrESS EntR” and “rEV 53XX”. Press ENTER.
8. The display will flash “Pro SoFt” as the software is uploading. It may take up to one minute for this to
complete. When complete, the display will show “Pro donE”.
NOTE
If a problem occurs while loading software, the display will blink the message “Pro FAIL” or “bad 12V.”
Turn unit power off “0” at the Start-Stop switch and remove the card.
9. Turn unit power off (“0”) at the Start-Stop switch (ST).
10. Remove the programming device from the controller.
11. Turn unit power on (“I”) at the Start-Stop switch (ST).
12. On power up, the controller LED flashes quickly and the display will remain blank as the controller loads the
new software. This takes about 15 seconds. When complete, the controller will reset and power up normally.
13. Bring up function code Cd18 to confirm that the correct software revision is loaded.
7.28.3
Changing Controller Configuration
1. Turn unit power off (“0”) at the Start-Stop switch (ST).
2. Inspect the pins on the controller’s programming slot for damage.
3. Insert the programming device (with proper software loaded) into the slot. See
.
4. Turn unit power on (“I”) at the Start-Stop switch (ST).
5. The display will show “Usb LOAd”. Use the Arrow keys to select "LOAd SoFt" and press the ENTER key.
The display will show "SEt UP"
.
NOTE
For PCMCIA sRAM cards, the display will show "SEt UP" when unit turns on.
6. Press the ENTER key on the keypad.
7. The display will show the message “ruN ConFG”. Press the ENTER key.
NOTE
If the display has blinking message “bAd CArd”, then the card is defective. Turn unit power off “0” at
the Start-Stop switch (ST) and remove the card.
8. The display module will go blank briefly and then display “5XX XXX”, based on the operational software
installed.
9. Use the Arrow keys to display the desired model number and then press ENTER.
10. When software loading has successfully completed, the display will show the message “COnFG donE.”
NOTE
If the display has blinking message “Pro FAIL” or “bad 12V”, then a problem has occurred while
loading the software. Turn unit power off “0” at the Start-Stop switch and remove the card.
11. Turn unit power off (“0”) at the Start-Stop switch (ST).
12. Remove the programming device from the controller.
13. Turn unit power on (“I”) at the Start-Stop switch (ST).
14. To confirm the correct model configuration was loaded, use the keypad to bring up function code Cd20. The
model displayed should match the last five digits of the model number listed on the unit nameplate.