Carrier PH4G Owner'S Information Manual Download Page 6

 © 2020 Carrier. All rights reserved.

A Carrier Company 

Edition Date: 08/20

Catalog No: OG-PH4G-05

Replaces: 

OG-PH4G-04

PH4G: Owner’s Information Manual

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.

6

Table 2 – Maintenance Checklist

Monthly maintenance items and outdoor unit rinsing may be performed by the consumer.  All other maintenance items and all service work must be

performed by a qualified service technician.  Read all Warning labels.

Description of Maintenance

Recommended Interval

Consumer specific:

Monthly

Annual

Inspect, clean, or replace air filter if filter is located indoors in return air duct.

X

Clear away debris and vegetation near unit.

X

Dealer specific:

Inspect cabinet and basepan for damage.  Replace panels, gaskets, and other components that are damaged or severely 

rusted.  Make sure precipitation has not  entered indoor section of unit.

X

Inspect electrical disconnect for proper function.  Repair or replace as necessary.

X

Inspect electrical wiring and connections.  Tighten loose connections.  Inspect and perform functional test of equipment as 

needed to ensure proper function.  Repair or replace damaged or overheated components and wiring.

X

Inspect electric heater, if installed.  Check for signs of overheating of elements, controls, and wiring.  Make sure heater 

elements are not broken or electically shorted.

X

Check refrigerant system subcooling and/or superheat  (system dependent).

X

Inspect inside of unit.  Clean if debris is present.

X

Inspect condenser coil.  Clean if dust, dirt, or debris is present.  Rinse unit with fresh water (see Note 2).

X

Inspect condenser motor and fan for damage.  Make sure fan spins freely.

X

Inspect and clean blower assembly (includes blower housing, wheel, and motor).

X

Inspect evaporator coil.  Clean if dust, dirt, or debris is present (see Note 2).

X

Clean condensate pan and drain lines (more frequent maintenance may be required in humid climates).

X

Inspect airflow system (ductwork).  Check for leaks and repair as needed.

X

Notes:

1. The above list may not include all maintenance items.  Inspection intervals may vary depending on climate and operating hours.  Consult your HVAC dealer about a service 

contract for seasonal inspections.

2. Do not use harsh chemicals or high pressure water on coils.  More frequent rinsing is required for units near a sea coast.

Reviews: