PG80MSU: Installation, Start-up, Operating and Service and Maintenance Instructions
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
2
A210783
Fig. 1 – Dimensional Drawing
Table 1 – Dimensions
SAFETY CONSIDERATIONS
FURNACE SIZE
A
CABINET WIDTH
IN. (MM)
B
OUTLET WIDTH
IN. (MM)
C
TOP FLUE
COLLAR ONLY
IN. (MM)
D
BOTTOM
INLET WIDTH
IN. (MM)
VENT
CONNECTION
IN. (MM) SIZE
SHIP WT. LB.
(KG)
36040B
17-1/2 (445)
15-7/8 (403)
11-9/16 (294)
16 (406)
4 (102)
123 (56)
48060B
17-1/2 (445)
15-7/8 (403)
11-9/16 (294)
16 (406)
4 (102)
127 (58)
60080C
21 (533)
19-3/8 (492)
13-5/16 (338)
19-1/2 (495)
4 (102)
149 (68)
60100C
21 (533)
19-3/8 (492)
13-5/16 (338)
19-1/2 (495)
4 (102)
153 (69)
WARNING
!
FIRE, EXPLOSION, ELECTRICAL SHOCK, AND
CARBON MONOXIDE POISONING HAZARD
Failure to follow this warning could result in dangerous operation,
serious injury, death, or property damage.
Improper installation, adjustment, alteration, service, maintenance, or
use could cause carbon monoxide poisoning, explosion, fire, electrical
shock, or other conditions which may cause personal injury or property
damage. Consult a qualified service agency, local gas supplier, or your
distributor or branch for information or assistance. The qualified
service agency must use only factory-authorized accessories and
replacement parts when installing and servicing this product.
WARNING
!
FIRE, EXPLOSION, ELECTRICAL SHOCK, AND
CARBON MONOXIDE POINSING HAZARD
Failure to follow this warning could result in dangerous operation,
personal injury, death, or property damage.
Furnaces shall NOT be twinned (i.e. tandem or staged operation) unless
approved in factory technical specifications literature for the furnace. A
factory authorized, field-supplied Twinning Kit MUST be used.
Consult furnace pre-sale literature for specific models approved for
twinning and the correct twinning kit. Twinned furnaces must be
installed on both a common supply AND a common return duct system
as shown in the Twinning Kit Installation Instructions. Only two
furnaces can be twinned on a common supply and return duct system
using a factory authorized twinning kit.