62-61753-21
2-16
2.8.4 Remote Temperature Sensors
The unit is provisioned to connect a up to three remote
temperature sensors directly to the microprocessor.
The microprocessor may be configured to display the
sensor reading in the Unit Data display and to record
the sensor reading in the Data Recorder. A user speci-
fied name may be configured for both sensors, this
name will be displayed (recorded) rather than the de-
fault Remote Sensor #1, Remote Sensor #2 or Re-
mote Sensor #3 name.
2.8.5 IntelliSet/ProductShield
The LogiCOLD Microprocessor offers over 48 parame-
ters that may be set depending on the product being
carried. IntelliSet allows the owner to pre-program
product specific settings into the microprocessor and
give the settings a name. The operator may then call
up these settings by simply selecting the IntelliSet
name.
In addition to the ability to pre-set the microprocessor
parameters, the IntelliSet option includes Prod-
uctShield. ProductShield is a group of nine Configura-
tions which may be set to provide enhanced product or
unit protection under extreme ambient conditions.
2.8.6 Remote Control Panel
The unit may be fitted with an optional remote control
panel. The panel displays refrigerated compartment
set point, compartment temperature and operating
mode (heat, cool or defrost). The set point may be set
and the unit may be started and stopped using the
remote panel.
This compact panels can be mounted to suit the indi-
vidual operator’s preferences - in the cab, on the front
bulkhead, or in the refrigerated compartment (including
in the wall itself). See Section 3.19.2 for more infor-
mation on the remote control panels.
2.9
ENGINE DATA
Engine Model
V1505-B-CTE-2 (CT4-91TV)
Displacement
1.498 liters
(91.41 in
3
n)
No. Cylinders
4
Rated Power
16.7 KW (22.4 hp) @1900 rpm
NOTE: Refer to Table 2-1 for engine speed settings
Weight
118 kg (260.2 lbs)
Coolant Capacity
7.8 liters (8.24 U.S. quarts) - 50/50 mix mono propylene glycol - never to exceed 60/40
Thermostat
Starts to open 81 to 83°C (177 to 182°F) Fully open at 95°C (203°F)
Oil Capacity with
Filter
13 liters (13.7 quarts)
Injection Setting
140 to 150
Bars (1991 to 2133 psig)
Fuel
Winter: Diesel No. 1 Summer: Diesel No. 2
Firing Order
1-3-4-2
Glow Plug Amperage
4 amps per plug at 12 VDC
Valve Clearance
Intake and Exhaust -Cold = 0.18 to 0.22 mm (0.0071 to 0.0087 inch)
Compression
Engine compression must be above 27.2 Bars (400 psig)
Lubrication System
Oil Pressure
2.8 To 4.2 Bars (40 to 62 psig) - Engine in high speed
Oil Pressure Safety
Switch (ENOPS)
Closes, on pressure rise, at 1.22 Bar (18 psig)
Opens, on pressure fall, at 0.82 Bar (12 psig)
Lube Oil Viscosity:
Outdoor Temperature
Grade (SAE)
Below 0°C (32°F)
10W or 15W40
0° to 25°C (32° to 77°F)
20W or 15W40
Over 25°C (Over 77°F)
30W or 15W40
Oil Change Intervals
Refer to Section 8.1 for information on service intervals.
Summary of Contents for NDK33BN0KB
Page 2: ......
Page 3: ...OPERATION SERVICE MANUAL for VECTOR 1550 1550 CITY Trailer Refrigeration Units...
Page 4: ......
Page 14: ......
Page 22: ...62 61753 21 1 8 1 5 SAFETY DECALS 62 61343 00 Rev or 62 02139 01 Rev C 62 02143 00 Rev...
Page 24: ...62 61753 21 1 10 62 60192 00 Rev D...
Page 30: ...62 61753 21 2 6...
Page 48: ......
Page 212: ......
Page 226: ......
Page 248: ......
Page 252: ......
Page 262: ......
Page 270: ......