1.4
SPECIFIC R-452A REFRIGERANT WARNING
AND CAUTION
WARNING
R-452A is an A1 non-flammable refrigerant
blend; however certain of its constituents
are considered A2L midly flammable.
For this raison, it is imperative that the sys-
tem of a vector unit utilizing R-452A refrig-
erant be reclaim to a sufficient vaccum to
ensure all residual refrigerant is removed
from the system
Follow the R-452A refrigerant reclaim / re-
covery procedure before performing any
“Hot work” including but not limited to
brazing or welding on a unit that has been
charged with R-452A, to prevent flare up of
residual A2L refrigerant constituents
Refrigerant must be reclaimed until equip-
ment gauge indicates 20 inHG (-0.6bar) of
vacuum.
Refer to Section 8.5.2Removing The R-
452A Refrigerant Charge
Refer to the Service Bulletin SB06-16 for
additional information
CAUTION
As distinct of R404A refrigerant, R-452A
has slidding properties more important and
not negligeable between vapour state and
liquid state.
For a given temperature, the liquid state
pressure value and the vapour state pres-
sure value, of the R-452A refrigerant are
differents.
Refer to section 10 for Temperature pres-
sure chart
Summary of Contents for NDK33BN0KB
Page 2: ......
Page 3: ...OPERATION SERVICE MANUAL for VECTOR 1550 1550 CITY Trailer Refrigeration Units...
Page 4: ......
Page 14: ......
Page 22: ...62 61753 21 1 8 1 5 SAFETY DECALS 62 61343 00 Rev or 62 02139 01 Rev C 62 02143 00 Rev...
Page 24: ...62 61753 21 1 10 62 60192 00 Rev D...
Page 30: ...62 61753 21 2 6...
Page 48: ......
Page 212: ......
Page 226: ......
Page 248: ......
Page 252: ......
Page 262: ......
Page 270: ......