62-61753-21
6-1
SECTION 6 -
MESSAGECENTER
6.1
MessageCenter MESSAGES
The following table lists all of the messages which do not appear in other lists in this manual and a description of
their meaning. Refer to Table 3-1 for a list of Unit Data messages. Refer to Table 3-2 for a list of Functional Param-
eter messages. Refer to Table 5-1 for a list of Component Test Messages Refer to Table 5-2 for a list of Configura-
tion messages. Refer to Section 5.1 for a list of Component Test messages. Refer to Section 7 for a list of Alarm
messages.
MessageCenter MESSAGES
Message
Description
TO SCROLL, THEN = TO LOCK
This message is used when viewing Unit Data. Use the UP and
DOWN
arrow keys to move through the Data list. Press the = key to
lock a Data item in the MessageCenter.
TO SCROLL, THEN = TO SAVE
Press the UP or DOWN arrow key to scroll through menu selections
available in this mode. When you reach the desired selection, press
the = key to store new value in microprocessor’s memory.
TO SCROLL, THEN = TO SELECT
Press the UP or DOWN arrow key to scroll through menu selections
available in this mode. When you reach the desired selection, press
the = key to select it.
= TO INSTALL, INSTALLS LEFT XX
An Option PC Card has been inserted into the PC Card slot. Press
the = key to install the option into the microprocessor. The number of
installs remaining on the PC Card will be shown.
ACTIVE
This message will appear in the MessageCenter along with the cur-
rent IntelliSet indicating that the IntelliSet is active and none of its
settings have been modified.
ACTIVE ALARM LIST CLEARED
The list of active alarms in the microprocessor has been erased.
(This does
not
remove alarms from the data recorder.)
ALL ALARMS CLEARED
The list of active and inactive alarms in the microprocessor alarm lists
have been erased. (This does
not
remove alarms from the data re-
corder.)
ALL INFO LOADED - REMOVE CARD
All data has been loaded into the microprocessor from the PC Card.
The card may be safely removed from the microprocessor.
BACK TO CONFIGS
Pressing the = key with this message showing will return the user to
the main microprocessor Configuration list.
BACK TO FUNC PARAMS
Pressing the = key with this message showing will return the user to
the main Functional Parameter list.
BAD PC CARD OR CARD SLOT
The microprocessor has detected a problem with either the PC card
or the PC card slot.
CANNOT ENTER TRIP START
Cannot enter Trip Start. A problem has been detected within the Data
Recorder.
CANNOT START DEFROST CYCLE
Due to current unit conditions, the defrost cycle cannot be started.
Refer to Section 3.9.
CANNOT START PRETRIP
Due to current unit conditions a Pretrip test cannot be started. Refer
to Pretrip Section 3.4.
CANNOT DOWNLOAD - BATTERY TOO
LOW
Data cannot be downloaded and software upgrades are prohibited
when battery voltage is below 7.0 volts. This message will be dis-
played until the serial cable is removed.
CARD FULL, REMOVE CARD
The PC Downloader Card is full. There is no additional room to down-
load information from the microprocessor. You may safely remove
the PC Card from the slot.
CARD LOCKED - REMOVE CARD
The lock switch on the PC Card is in the "Locked" position. To use
the PC Card, move the switch to the "Unlocked" position.
Summary of Contents for NDK33BN0KB
Page 2: ......
Page 3: ...OPERATION SERVICE MANUAL for VECTOR 1550 1550 CITY Trailer Refrigeration Units...
Page 4: ......
Page 14: ......
Page 22: ...62 61753 21 1 8 1 5 SAFETY DECALS 62 61343 00 Rev or 62 02139 01 Rev C 62 02143 00 Rev...
Page 24: ...62 61753 21 1 10 62 60192 00 Rev D...
Page 30: ...62 61753 21 2 6...
Page 48: ......
Page 212: ......
Page 226: ......
Page 248: ......
Page 252: ......
Page 262: ......
Page 270: ......