background image

1

50XT---A

Infinity

r

15 SEER

Single Packaged Heat Pump System

with Puron

R

(R---410A) Refrigerant

Owner’s Information Manual

A09032

Fig. 1 -- Unit 50XT--A

NOTE TO EQUIPMENT OWNER:

For your convenience, please record the model and serial numbers of your new equipment in the spaces

provided. This information, along with the installation data and dealer contact information, will be helpful

should your system require maintenance or service.

UNIT INFORMATION

Model # _____________________________________
Serial # ______________________________________

ACCESSORIES (List type and model #)

_____________________________________________
_____________________________________________
_____________________________________________

INSTALLATION INFORMATION

Date Installed ________________________________

DEALERSHIP CONTACT INFORMATION

Company Name_______________________________
Address______________________________________
_____________________________________________
Phone Number _______________________________
Technician Name _____________________________
_____________________________________________

NOTE TO INSTALLER:

This manual must be left with the equipment owner.

Summary of Contents for INFINITY 50XT-A

Page 1: ...____________ Serial ______________________________________ ACCESSORIES List type and model _____________________________________________ _____________________________________________ _____________________________________________ INSTALLATION INFORMATION Date Installed ________________________________ DEALERSHIP CONTACT INFORMATION Company Name_______________________________ Address________________...

Page 2: ...protect your investment and to eliminate unnecessary ser vice calls familiarize yourself with the following facts 1 During heating increasing the desired temperature setting more than 2 F 1 1 C may cause the supplemental heaters to be turned on for a short period of time to satisfy the demand Needless use of the supplementary heat reduces potential energy savings 2 Ice or frost tends to form on th...

Page 3: ...s or reaching into the unit WARNING Air Filters The air filter s should be checked at least every 3 months and changed or cleaned whenever it becomes dirty Dirty filters produce excessive stress on the blower motor and can cause the motor to overheat and shut down This unit must have an air filter in place before it can be operated These filters should be located in at least one of two places In m...

Page 4: ...it casing for signs of deterioration 7 Inspection of all electrical wiring and components to assure proper connection 8 Inspection for leaks in the refrigerant circuit Pressure check to determine appropriate refrigerant charge 9 Inspection of compressor oil level by service person to ensure proper oil level is maintained in the compressor when it is installed and running 10 Operational check of th...

Reviews: