background image

Owner’s Manual

A NOTE ABOUT SAFETY

Any time you see this symbol    in manuals, instructions and on the

unit, be aware of the potential for personal injury.  There are three levels

of precaution:

WARNING

  signifies  hazards  that  could  result  in  personal  injury  or

death. 

CAUTION

 is used to  identify unsafe practices which  would  result in

minor personal injury or product and property damage.

NOTE

 is  used to  highlight suggestions  which  will  result in  enhanced

installation, reliability, or operation.

ABOUT YOUR HEAT PUMP SYSTEM

Our  products  are  designed,  tested  and  built  in  accordance  with  US

Department  of  Energy  standardized  procedures  and  other  standards;

however,  actual  operating  results  and  efficiencies  may  vary  based  on

manufacturing  and  supplier  tolerances,  equipment  configuration,

operating conditions and installation practices.

IDENTIFYING YOUR SYSTEM

Your new Carrier heat pump system is what we call a ”split system.”  It

has  an  outdoor  unit  and  an  indoor  unit  connected  to  each  other  with

copper tubing called refrigerant lines.  Each of these units has a rating

plate with the model and serial numbers you will need to reference when

calling an authorized Carrier dealer about your system.  

Take a few moments now to locate those numbers and record them for

future reference.

USING YOUR NEW CARRIER

 SYSTEM

Your Carrier heat pump system is controlled by a wall-mounted Infinity

Control  installed  inside  your  home.   This  system  requires  an  Infinity

Control which has software designed specifically to operate this system.

See the Infinity Control Homeowner Guide for more details on system

operation.

VARIABLE SPEED OPERATION

You  may  notice  your  system  runs  for  longer  periods  of  time.    This

system is designed to meet cooling or heating needs of the home at a

wide range of conditions.   Your  indoor  temperature will  remain more

consistent with fewer drafts, better humidity control, enhanced comfort

and enhanced energy efficiency.  

HEATING AND COOLING YOUR HOME

For heating or cooling operation, make sure the System or Mode control

is set to the appropriate mode.  Then, adjust the Temperature control to

your  desired setting.   Finally,  use the  Fan control to  select Automatic

(turns on and off as heating is needed) or On (runs continuously). 

Depending  on  your  typical  heating  needs,  your  home  comfort  system

may also include a supplementary heating source that will automatically

turn  on  as  needed.   You  may  also  select  this  heat  source  manually  if

desired.

OPERATION UNDER EXTREME CONDITIONS

Your  heat  pump  will  run  as  long  as  necessary  to  maintain  the  indoor

temperature selected on your Infinity Control. On extremely hot days,

your heat pump will run for longer periods at a time than on moderate

days.   Your  system will  also  run  for longer periods  of time under the

following conditions:

• Frequent opening of exterior doors 

• Operating laundry appliances

• Taking hot showers

• More than the usual number of people present in the home

• More than the normal number of electric lights in use

• Drapes or blinds are open on the sunny side of the home

IMPORTANT HEAT PUMP FACTS 

Heat pump systems have a few unique features and operations that you

should be aware of: 

• During the heating cycle, your heat pump delivers a constant flow of

air at around 95°F (35°C)to about 105°F (41°C), compared to sudden

blasts of hot air provided by a typical furnace.  

• Ice  or  frost  may  form  on  the  outdoor  coil  during  winter  heating

operation. Your  heat  pump  will  automatically  melt the ice  using its

defrost cycle. During defrost, you may see steam or fog rising from

the outdoor unit, which is normal. At the beginning and end of the

defrost cycle, you may hear a ”whoosh” sound coming from the unit.

This is normal for heat pump applications. 

• Heat  pumps  installed  in  areas  expecting  snow  are  elevated  with

support feet.

SOUND

Your new heat pump with Greenspeed Intelligence is different from most

heating and cooling systems. Because this is a variable speed system, it

is designed to operate at different speeds depending on the temperature

and  humidity  conditions. You  may  notice  the  sound  coming  from  the

outdoor unit changing from time to time, and from season to season. In

winter, the system will operate at higher speeds as it gets colder outside

to maintain its heating performance. The higher speed produces a higher

sound.  This  change  of  speeds  allows  the  system  to  operate  more

efficiently and maintain comfortable conditions inside the home.  You

may also hear a slight “purr” at start-up and shut down.  These sounds

are normal and do not represent a problem with your system.

ROUTINE MAINTENANCE

Simple, routine maintenance as described below will enhance your heat

pump system’s ability to operate economically and dependably. Always

remember the following safety precautions:

25VNA4 

Infinity™Variable Speed Heat Pump

with Greenspeed™ Intelligence

2-5 Nominal Tons

WARNING

!

PERSONAL INJURY, DEATH AND / OR PROPERTY 

DAMAGE HAZARD

Failure to follow this warning could result in personal injury, death or

property damage.

Improper  installation, adjustment, alteration, service,  maintenance,  or

use  can  cause  explosion,  fire,  electrical  shock,  or  other  conditions

which  may  cause  personal  injury  or  property  damage.    Consult  a

qualified  installer,  service  agency,  or  your  distributor  or  branch  for

information  or  assistance.    The  qualified  installer  or  service  agency

must  use  factory-authorized  kits  or  accessories  when  modifying  this

product.

Read and follow all instructions and warnings, including labels shipped

with or attached to unit before operating your new heat pump.

Reviews: