A NOTE ABOUT SAFETY

Any time you see this symbol 

 in manuals, instructions and on the

unit, be aware of the potential for personal injury. There are three levels
of precaution:

DANGER  identifies the most serious hazards which will result in
severe personal injury or death.

WARNING signifies hazards that could result in personal injury or
death.

CAUTION is used to identify unsafe practices which could result in
minor personal injury or product and property damage.

NOTE is used to highlight suggestions which will result in enhanced
installation, reliability, or operation.

PERSONAL INJURY, DEATH AND / OR PROPERTY
DAMAGE HAZARD

Failure to follow this warning could result in personal injury,
death or property damage.

Improper installation, adjustment, alteration, service,
maintenance, or use can cause explosion, fire, electrical shock,
or other conditions which may cause personal injury or
property damage. Consult a qualified installer, service agency,
or your distributor or branch for information or assistance. The
qualified installer or service agency must use
factory−authorized kits or accessories when modifying this
product.

Read and follow all instructions and warnings, including labels
shipped with or attached to unit before operating your new air
conditioner.

!

WARNING

GENERAL

The ducted fan coil unit provides quiet, maximum comfort. In
addition to cooling and/or heating, the ducted fan coil unit matched
with an outdoor condensing unit filters and dehumidifies the air in
the room to provide maximum comfort.

IMPORTANT:

 

The ducted fan coil unit should be installed by

authorized personnel only; using approved tubing and accessories. If
technical assistance, service or repair is needed, contact the installer. 
The ducted fan coil unit can be set up and operated from the remote
control (provided). If the remote is misplaced, the system can be
operated from the “Auto” setting on the unit.

OPERATING MODES

The ducted fan coil unit has five operating modes:

S

Fan only

S

Auto

S

Heating (heat pump models only)

S

Cooling

S

Dehumidification (DRY)

Fan Only

In  FAN ONLY mode, the system filters and circulates the room air
without changing room air temperature.

Auto

In  AUTO mode, the system automatically cools or heats the room
according to the user−selected set point.

NOTE:  AUTO mode is recommended for use on single zone
applications only. Using Auto changeover on multi−zone applications
could set an indoor unit to STANDBY mode, indicated with two dashes
(−−) on the display, which will turn off the indoor unit until all the
indoor units are in the same mode (COOLING or HEATING).
Heating is the system’s priority mode. Simultaneous HEATING and

COOLING is not allowed.

Heating

In  HEATING mode, the system heats and filters the room air.

Cooling

In  COOLING mode, the system cools, dries and filters the room air.

Dehumidification (DRY)

In  DEHUMIDIFICATION mode, the system dries, filters and
slightly cools the room air temperature. This mode prioritizes air
dehumidification but it does not take the place of a dehumidifier.

WIRELESS REMOTE CONTROL

The remote control transmits commands to set up and operate the
system. The control has a window display panel that displays the
current system status. The control can be secured to a surface when
used with the mounting bracket provided.

WIRED REMOTE CONTROL (OPTIONAL)

Summary of Contents for DLFLDA Series

Page 1: ...your new equipment in the spaces provided This information along with the installation data and dealer contact information will be helpful should your system require maintenance or service UNIT INFORM...

Page 2: ...MPORTANT The ducted fan coil unit should be installed by authorized personnel only using approved tubing and accessories If technical assistance service or repair is needed contact the installer The d...

Page 3: ...R WIRELESS REMOTE Air outlet Air inlet Air filter Drain hose field supplied Electric control cabinet Refrigerant connecting pipe field supplied ON OF F T E MP FP TIMER ON TIMER OFF MODE FAN SLC SLEEP...

Page 4: ...ll flash on the display area Then press the or button to confirm SLEEP Function This function maintains the most comfortable temperature and saves energy It is available in COOL HEAT or AUTO modes onl...

Page 5: ...compartment 3 Replace the battery compartment cover NOTE 1 When replacing batteries do not use old batteries or a different type battery This may cause the remote control to malfunction 2 If the remot...

Page 6: ...y Setting the Room Temperature Set Point Press the increase temperature set point Y and decrease B buttons to raise or lower the temperature The unit confirms the signal receipt with a beep and the va...

Page 7: ...of the unit Set the Auto On Time 1 Press the SET button The Timer on indicator displays and flashes The last Auto on setting time and the signal h shows on the LCD display area Now it is ready to res...

Page 8: ...ill show the temperature again The indicator remains on and this function is activated Combined Timer Setting both ON and OFF timers simultaneously TIMER OFF TIMER ON On Stop Start operation Fig 15 Co...

Page 9: ...trol sends this signal to the air conditioner every 3 minutes This function is not available for DRY and FAN modes Freeze Protection Mode Press FP for approximately 2 seconds to activate or deactivate...

Page 10: ...must be replaced Contact your local dealer for replacement filters 1 Unscrew filters from the frame 2 Pull filters down to remove A150678 Fig 17 Remove the Filters 3 Vacuum filters A150648 Fig 18 Vacu...

Page 11: ...OR UNIT EVERY MONTH EVERY 6 MONTHS EVERY YEAR Clean Air Filter Change Remote Control Batteries S S OUTDOOR UNIT EVERY MONTH EVERY 6 MONTHS EVERY YEAR Clean Outdoor Coil from Outside Clean Outdoor Coil...

Page 12: ...e unit may accumulate dust during extended periods of non use which will be emitted when the unit is turned on This can be mitigated by covering the unit during long periods of inactivity The unit emi...