background image

 

®

 

HEAT

COOL

M

AM

 

HOME OWNER’S GUIDE

 

NOTE TO INSTALLER: THIS MANUAL SHOULD BE LEFT WITH THE EQUIPMENT USER.

 

COMFORT ZONE

 

A GUIDE TO OPERATING YOUR RESIDENTIAL COMFORT ZONE SYSTEM

Summary of Contents for Comfort Zone Controller

Page 1: ... HEAT COOL M AM HOME OWNER S GUIDE NOTE TO INSTALLER THIS MANUAL SHOULD BE LEFT WITH THE EQUIPMENT USER COMFORT ZONE A GUIDE TO OPERATING YOUR RESIDENTIAL COMFORT ZONE SYSTEM ...

Page 2: ...emands of each zone at different times during the day and the week To make programming the system easier it s a good idea to become familiar with the various parts of the Comfort Zone Controller A95554 1 Controller Display Indicates zone set points zone temperatures and programming information and allows setpoint adjustment 2 Clock Display Indicates the current time and day and the start times wee...

Page 3: ...ng or cooling is required Emergency Heat Switch Heat Pump Systems A95558 OFF Electric strip heat will not come on unless there is a zone more than 2 F below the desired heat setpoint and comfort trend demand has been satisfied ON When any zone requires heat the electric strip heating will turn on The compressor will remain off HEAT OFF OFF AUTO HEAT COOL FAN EMERGENCY HEAT AUTO OFF ON ON AUTO HEAT...

Page 4: ... the zone setpoints and zone temperature every 2 sec Cooling Setpoint Buttons Heating Setpoint Press to raise or lower Press to raise or lower Cooling Setpoints Heating Setpoints Cooling Setpoint Heating Setpoint A95559 By pressing the upper and lower HEAT or COOL setpoint buttons simultaneously the controller display will freeze display showing indoor zone temperature Push again to release A95560...

Page 5: ... day Each zone can be programmed independently Example Weekly Schedule Zone 1 Family and Living Rooms A95563 A chart similar to the 1 in the example above has been provided in the back of this manual to assist you in programming Complete the chart for Zones Week Periods Start Times and Setpoints then use the chart to program the controller NOTE If no program schedules are desired for a particular ...

Page 6: ... normal independent zone operation will resume This mode can also be used to maintain the entire building at 1 constant temperature NOTE If the FAN switch is set to ON the fan will continue to run in vacation mode To enter vacation mode turn the selector dial to vacation The word VACATION will appear on the controller display whenever the system is in vacation mode A95564 A95565 9 S T ZONE 1 OPTIO...

Page 7: ...T MIN HR DAY button once Press the ADVANCE TIME DAY button to scroll to the proper minutes A95567 2 Set the Hour Press the SELECT MIN HR DAY button once again Press the ADVANCE TIME DAY button to scroll to the proper hr AM or PM A95568 M AM SET TIME TEMP SCHEDULES HOLD TEMPERATURES SELECT MIN HR DAY ADVANCE TIME DAY AM SET TIME TEMP SCHEDULES HOLD TEMPERATURES SELECT MIN HR DAY ADVANCE TIME DAY ...

Page 8: ...ll to the proper day A95569 4 Return to Normal Operation Press the SELECT MIN HR DAY button once again The newly programmed time and day will be displayed A95570 T SET TIME TEMP SCHEDULES HOLD TEMPERATURES SELECT MIN HR DAY ADVANCE TIME DAY SET TIME TEMP SCHEDULES HOLD TEMPERATURES SELECT MIN HR DAY ADVANCE TIME DAY T AM ...

Page 9: ...controller display A95571 A95572 2 Select a Zone Turn the Selection Dial to the ZONE to be programmed Choices are ZONE 1 ZONE 2 ZONE 3 or ZONE 4 A95561 A95573 HOLD TEMPERATURES SELECT MIN HR DAY ADVANCE TIME DAY SET TIME TEMP SCHEDULES HEAT PROGRAM COOL 9 S T ZONE 1 OPTIONS VACATION ZONE 2 ZONE 4 ZONE 3 8 7 6 5 4 3 2 1 HEAT PROGRAM COOL HEAT PROGRAM COOL HEAT PROGRAM COOL HEAT PROGRAM COOL ZONE 1 ...

Page 10: ...___________ 4 Program Time Periods There are 4 start times that can be programmed in each weekly period Press the SELECT MIN HR DAY button to program the start times for the selected weekly period Pressing the SELECT MIN HR DAY button 1 time shows the first program start time on the clock display and the setpoints with the word PROGRAM for this start time A95575 on the controller display A95578 A9...

Page 11: ... and setpoints Additional presses will display start times 3 and 4 then return to weekly period display A95575 A95578 A95579 NOTE While in the program mode if a period of 4 1 2 minutes passes without a change to some value the controller will revert to normal operation SET TIME TEMP SCHEDULES HOLD TEMPERATURES SELECT MIN HR DAY ADVANCE TIME DAY HEAT PROGRAM COOL AM ...

Page 12: ... period programming error Press the ADVANCE TIME DAY button until the desired start time is displayed A95574 A95579 RIGHT 6 AM Time Period 1 8 AM Time Period 2 5 PM Time Period 3 9 PM Time Period 4 WRONG 6 AM Time Period 1 2 AM Time Period 2 9 PM Time Period 3 5 PM Time Period 4 WRONG 8 AM Time Period 1 5 PM Time Period 2 2 AM Time Period 3 6 AM Time Period 4 SET TIME TEMP SCHEDULES HOLD TEMPERATU...

Page 13: ...aining weekly period start times Each weekly period can be programmed with 4 different time periods 8 Complete Week Schedule After completing start time programming press the SELECT MIN HR DAY button until MTWTHF reappears in the clock display Repeat steps 3 through 7 to program remaining weekly periods Once finished this will complete the programming of 1 zone 9 Program a Different Zone To progra...

Page 14: ...ing Setpoint Heating Setpoint A95581 If the HOLD TEMPERATURES button is pressed the current setpoints will not change with time but remain at the last values entered for as long as the hold mode is active To release the hold mode press the HOLD TEMPERATURES button a second time A95582 The controller display will show the word HOLD whenever the hold mode is active A95583 SET TIME TEMP SCHEDULES SEL...

Page 15: ...ted period 6 Adjust temperature setpoints for selected period 7 Repeat steps 4 6 to program remaining periods in daily schedule 8 Repeat steps 3 7 to program remaining weekly periods 9 Repeat steps 2 8 to program remaining zones 10 Press SET TIME TEMP SCHEDULES at any time to exit program mode Time Set 1 Press SELECT MIN HR DAY to enter time set mode 2 Press ADVANCE TIME DAY to change minutes 3 Re...

Page 16: ...rrier Corporation Form OMZONEKIT4 1 Supercedes New Printed in the U S A 3 96 PC 101 Catalog No 809 575 PROGRAMMING CHART A95584 ZONE 1 MTWTHF SA SU AREA COMMENTS START TIME TIME PERIOD 4 Cool Heat Cool Heat Cool Heat START TIME START TIME TIME PERIOD 3 TIME PERIOD 2 TIME PERIOD 1 ZONE 2 MTWTHF SA SU AREA COMMENTS START TIME TIME PERIOD 4 Cool Heat Cool Heat Cool Heat START TIME START TIME TIME PER...