background image

Commercial reference: 9001

Developed by CAVIUS

PLEASE  READ THE USER GUIDE CARE-

FULLY BEFORE USE AND RETAIN FOR 

FUTURE USE!

GENERAL  DESCRIPTION 

The Smart Remote is designed to alert with a 

rapid flashing warning light when alarming and to 

remotely control the CAVIUS Wireless Alarm Fam-

ily. The torch function can be used to find escape 

routes at night.

SAFETY INSTRUCTIONS 

Batteries are to be handled with care and battery 

powered devices should be kept out of reach of chil-

dren. Do not try to recharge or burn the batteries.
TECHNICAL INFORMATION

The Smart Remote can be used with the alarms from 

the CAVIUS Wireless Alarm Family: Smoke, Heat, 

Flood and Mains Power alarms. The maximum 

number of alarms that can be interlinked with is 32. 

The minimum range is 100m in open field. RF condi-

tions also depend on the house layout and materials. 

You should always test it after installation and after 

changing batteries.
Diameter: 27mm. Length: 140mm.

The Smart Remote is powered by 3 replaceable AAA 

batteries. 
Complies to standards: RoHS, REACH, EN60065.
1.  HOW TO CONNECT TO THE WIRELESS 

ALARM FAMILY:

Open the battery compartment by pressing the 

snap. Insert the batteries in the battery compart-

ment respecting polarities.

Slide the learn switch to the “Learn mode” posi-

tion. The Smart Remote will go into Learn mode.
All alarms that need to be connected to the 

Smart Remote in the house should be put into 

“Learn mode” by sliding the switch of each device 

on the “Learn mode” position.

The flashlight will light up to indicate that “Learn 

mode” has been selected.

Please note: Do not take out the batteries during 

“Learn mode” as this will interrupt the learn process.
Press and hold the test button on an alarm, of 

your own choice, until it beeps and the LED 

flashes. This alarm will become the master and 

will start sending out a specific house code to 

the other alarms.

As  the  other  alarms  receive  the  specific  house 

code, they will also start flashing their red LED’s. 

When  the red LED light flashes on all alarms, 

they are connected and MUST BE SWITCHED 

OUT OF ‘LEARN MODE’ and installed. 
Label the original “Learn” alarm in order to easily 

add new CAVIUS Wireless Family alarms to the 

system.
2. INSTALLATION:
The body of the Smart Remote has a built-in magnet, 

so it can be installed on a metal plate mounted on 

the wall, or on a fridge or other metal surfaces.

The accompanying metal plate can be installed by 

the double sided tape or the enclosed screw set. 

The end cap has a hole in which a lanyard can 

be added so the remote can hang from a hook 

etc.
3. TEST FUNCTION:
After installation, and at least once per quarter, 

test all your alarms by pressing the test button on 

the remote to ensure they are operating correctly 

and are within range of each other.

It is recommended to check visually every week 

if the LED flashes correctly on the alarm (every 

48sec.).
Hold the red end button for two swipes of alarms 

until the remote stops flashing, sounding and vi-

brating.
The remote is now transmitting a test signal to 

your alarms. During the test, the Smart Remote will 

flash and sound.

 

If the Smart Remote is receiving a test signal from 

another device, it will also flash and sound to 

indicate that it is part of the group. Indication can 

be stopped by pressing the end button.
Please note: To ensure an optimal operation in nor-

mal conditions, test function sends out a reduced 

power RF signal.
4. ALARM MODE:
When one of the connected alarms is going into 

alarm and sending out the RF alarm signal, the 

Smart Remote’s flashlight will start flashing rapidly 

(stroboscope).
The Smart remote has a built in vibrator and 

sounder which will follow the sound pattern of 

the originating alarm. During the alarm, both the 

sounder and vibrator will be activated.
The torch can be switched from stroboscopic flash-

ing to  constant on by pressing the side button.
Please note:  Flashlight  will  flash  at  2  Hertz  (2 

times each second) to avoid photo sensitive 

epilepsy to be triggered.
The CAVIUS Wireless Family has two different 

alarm signals: 
Alarm signal 1  (---  ---  ---)  is  life  threatening 

alarms, like a smoke alarm. 
Alarm signal 2  (-  -  -)  is  a  non  life  threatening 

alarm, like a flooding alarm:

Smoke alarm signal:             --- --- ---

Heat alarm signal:                --- --- ---

Flood alarm signal:               -    -   -   
Please note that only the originating alarm’s LED 

will flash, so it can be identified.

UK

End button for test/hush

Magnet holder

Learn mode switch

Flashlight

End cap for battery access

Side button for flashlight

Normal Mode

Learn Mode